TROUBLESHOOTING
All work on electrical parts or electrical connections and the refrigerant circuit must be carried out
by qualified and authorised personnel.
Warning: Disconnect electrical power before performing any operations on electrical parts or on
electrical connections.
Please also see the Display Errors Table at point 2.1.6.
Defect
Possible cause
Intervention
The refrigerator does not
cool, the compressor will
not start.
No electrical power. Battery
in poor conditions. Faulty
thermostat. Defective
electronic control unit.
Check to make sure that the electronic
control unit is receiving sufficient power
and voltage; check the fuse. Verify that
the internal lighting is working and that
the compressor is receiving power.
Check the cables, lugs and connectors.
Verify that the battery is charging
properly. Check the thermostat: Bridge
T - C with a separate cable. If the
compressor will not start, its electronics
are probably defective. Replace. If the
compressor starts up with the bridge,
the thermostat is defective. Replace
the thermostat.
The compressor only
performs brief attempts at
starting up.
There is insufficient voltage or
else a drop in voltage during
the attempt to start. The
protection device is activated.
The Batteries are drained.
Check the cables and connections;
remove any traces of oxidation or
corrosion. Charge the batteries, start
the motor or connect the battery
charger.
The compressor functions
but doesn’t cool.
Loss of refrigerant through
the evaporator or the
tubing. Tubing clogged.
Carry out a leak check and repair
any leaks, drain and refill the proper
amount of R134a refrigerant. (This
operation must be carried out by a
qualified technician.)
The compressor runs for
a long time but doesn’t
cool properly (reduced
efficiency).
Insufficient ventilation,
the condensation unit is
overheating. The fan is not
working properly. There is too
much frost on the evaporator.
The door does not close
properly and lets in warm,
moist air. The condenser is
blocked by dust.
Increase the ventilation. Replace
the fan. Defrost the unit. Correct the
position of the door and check the
gasket. Clean the condensing unit.
Summary of Contents for TB 30 AM DRAWER
Page 2: ......
Page 3: ...TB 30 AM DRAWER TB30AM DRAWER_20 06 2018 3 ITALIANO Fig 1 Fig 2...
Page 4: ...TB 30 AM DRAWER 4 TB30AM DRAWER_20 06 2018 ITALIANO Fig 3 Fig 4 Fig 5...
Page 5: ...TB 30 AM DRAWER TB30AM DRAWER_20 06 2018 5 ITALIANO...
Page 112: ...SUOMI TB 30 AM DRAWER 112 TB30AM DRAWER_20 06 2018 PRO VALIKON ASETUKSIEN GRAAFINEN ESITYS...
Page 143: ...TB 30 AM DRAWER TB30AM DRAWER_20 06 2018 143 Indel B S r l Indel B S r l 115 230...
Page 144: ...TB 30 AM DRAWER 144 TB30AM DRAWER_20 06 2018 8 4 3 2 1 1 4 1 4 2 3 Pro...
Page 146: ...TB 30 AM DRAWER 146 TB30AM DRAWER_20 06 2018 PRO...
Page 150: ...TB 30 AM DRAWER 150 TB30AM DRAWER_20 06 2018 Indel B S r l...
Page 151: ...TB 30 AM DRAWER TB30AM DRAWER_20 06 2018 151 EN 603 335 1 5 Heavy Current Regulations 115 230...
Page 155: ...TB 30 AM DRAWER TB30AM DRAWER_20 06 2018 155 2 1 6 T C R134a 4 4...
Page 156: ...TB 30 AM DRAWER 156 TB30AM DRAWER_20 06 2018 C P C T Indel B TB 30 AM DRAWER...
Page 157: ...TB 30 AM DRAWER TB30AM DRAWER_20 06 2018 157 TB 30 AM DRAWER 2 Indel B b S N S N...
Page 158: ...TB 30 AM DRAWER 158 TB30AM DRAWER_20 06 2018 Indel B 2012 19 EU WEEE...