TB 30 AM DRAWER
ENGLISH
TB30AM DRAWER_
20-06-2018
29
USAGE RECOMMENDATIONS
• If possible, the refrigerator should be turned on for about 6 hours prior to inserting the food items.
• Frequent opening of the refrigerator door will result in greater power consumption.
• Ensuring adequate ventilation for the compressor and the condensing unit will significantly reduce
power consumption.
• Never obstruct the refrigerator’s ventilation system.
• The electrical system must be kept in good condition. Inspect the batteries and check the charge
levels regularly. Always use a starter battery separate from the motor.
• Keep the inside of the refrigerator clean and dry. Remove the condensation water from the drip
tray beneath the refrigerator’s freezer compartment where present.
• To keep the surface of the door in good conditions and intact, make sure that it is always clean
and dry.
• The unit has been designed with a product lock protection in the event of low battery voltage. In
the event of a compressor block, follow the instructions in this manual and/or contact specialised
technicians or Indel B service centres.
• The compressor can operate up to an angle of 30°, while greater angles can cause permanent
damage to the compressor.
DEFROSTING
Since the evaporator operates at temperatures well below freezing, ice and frost will inevitably
form upon it.
The humidity in the air, the temperature and the number of times the door is opened will have a
significant impact on frost formation.
The refrigerator should always be defrosted when the layer of frost on the evaporator reaches a
thickness of 3-4 mm or more.
Turn off the refrigerator by turning the thermostat to its 0 position.
Defrosting should be performed when the products can remain as cool as possible outside of the
refrigerator itself. Do not use sharp objects to remove ice and frost from the evaporator, as this
could damage it and result in leaks.
Only turn the refrigerator back on once it has been defrosted, cleaned and thoroughly dried. A
towel can be placed at the base of the refrigerator during the defrosting procedure in order to
facilitate water collection.
MAINTENANCE
TB 30 AM DRAWER Drawer refrigerators are equipped with closed cooling systems, which do not
require maintenance or refrigerant refills.
The compressor is specifically designed for mobile applications and guarantees maximum
performance and durability. In the winter, the refrigerator must be stored inside the vehicle, but
the compressor will not work at temperatures near or below 0°C. Seasonal maintenance is limited
to the cleaning of the condensing unit behind the refrigerator. In particular, it is necessary to
brush/vacuum out all the dust that has accumulated due to the fan. This can be done using a soft
brush and a vacuum cleaner. It is important to keep the inside of the refrigerator clean by washing
Summary of Contents for TB 30 AM DRAWER
Page 2: ......
Page 3: ...TB 30 AM DRAWER TB30AM DRAWER_20 06 2018 3 ITALIANO Fig 1 Fig 2...
Page 4: ...TB 30 AM DRAWER 4 TB30AM DRAWER_20 06 2018 ITALIANO Fig 3 Fig 4 Fig 5...
Page 5: ...TB 30 AM DRAWER TB30AM DRAWER_20 06 2018 5 ITALIANO...
Page 112: ...SUOMI TB 30 AM DRAWER 112 TB30AM DRAWER_20 06 2018 PRO VALIKON ASETUKSIEN GRAAFINEN ESITYS...
Page 143: ...TB 30 AM DRAWER TB30AM DRAWER_20 06 2018 143 Indel B S r l Indel B S r l 115 230...
Page 144: ...TB 30 AM DRAWER 144 TB30AM DRAWER_20 06 2018 8 4 3 2 1 1 4 1 4 2 3 Pro...
Page 146: ...TB 30 AM DRAWER 146 TB30AM DRAWER_20 06 2018 PRO...
Page 150: ...TB 30 AM DRAWER 150 TB30AM DRAWER_20 06 2018 Indel B S r l...
Page 151: ...TB 30 AM DRAWER TB30AM DRAWER_20 06 2018 151 EN 603 335 1 5 Heavy Current Regulations 115 230...
Page 155: ...TB 30 AM DRAWER TB30AM DRAWER_20 06 2018 155 2 1 6 T C R134a 4 4...
Page 156: ...TB 30 AM DRAWER 156 TB30AM DRAWER_20 06 2018 C P C T Indel B TB 30 AM DRAWER...
Page 157: ...TB 30 AM DRAWER TB30AM DRAWER_20 06 2018 157 TB 30 AM DRAWER 2 Indel B b S N S N...
Page 158: ...TB 30 AM DRAWER 158 TB30AM DRAWER_20 06 2018 Indel B 2012 19 EU WEEE...