![Indel B sleeping well arctic plus SW2000PLUS Installation, Maintenance And Use Instructions Download Page 17](http://html1.mh-extra.com/html/indel-b/sleeping-well-arctic-plus-sw2000plus/sleeping-well-arctic-plus-sw2000plus_installation-maintenance-and-use-instructions_2051367017.webp)
17
OPERATION / CONTROL PANEL
“SLEEPING WELL ARCTIC PLUS” CAN BE USED BY ACTIVATING THE AIR CONDITIONING OR THE FAN FUNCTION ONLY.
CONDITIONING (AC)
T
0
: TEMPERATURE SET BY USER
T
amb
: AMBIENT TEMPERATURE DETECTED BY PROBE
V
1
: COMPRESSOR ROTATION SPEED (2500 Rpm)
V
2
: COMPRESSOR ROTATION SPEED (4000 Rpm)
ON/OFF
When the system is OFF, press the
ON/OFF button (see fig. 1)
for more than one (1) second to turn
the A/C system ON. The A/C system will start in STANDARD MODE (
V
1
).
When the system is ON, press the ON/OFF button for more than two (2) seconds to turn the A/C
system OFF.
When the system is turned ON, the ventilation fan automatically starts thirty (30) seconds later.
The display always shows the temperature
set by the user (T
0
)
.
The temperature
can be set by the driver is between 20°C/68° and 28°C/84.4°F
.
OPTION
When this feature (button) is used, it will hold the compressor system at low speed “
V
1
”. This is a
battery saving feature that will allow the system to operate for longer periods of time when required.
VENTILATION (FAN)
If the fan increase or reduction buttons (
VENT + or VENT -)
are pressed when the system is switched
off, only the evaporator fan is activated, with the choice of 6 different speeds, shown on the central
control unit display.
To switch off the fan it is necessary to set the value 0 on the central control unit display, using the fan
speed reduction button (
VENT -
).
AUTO-LOW VOLTAGE SHUTDOWN (AC / FAN)
The Auto-Low voltage shutdown function turns OFF the power at
10.8V D.C.
In this case, the system (AC or VENT) shuts down, also deactivating the fan function and the
message
E1 appears
on the display and the
battery
symbol
lights up
.
When the power returns, for
at least 10 seconds
, to the value of
11.7V D.C.
, the system is
automatically reactivated, starting up the condenser fan, followed by the evaporator fan and
compressor.
Summary of Contents for sleeping well arctic plus SW2000PLUS
Page 3: ...3 SLEEPING WELL ARCTIC PLUS ...
Page 5: ...5 ...
Page 6: ...6 ...
Page 7: ...7 ...
Page 8: ...8 ...
Page 9: ...9 ...
Page 10: ...10 ...
Page 12: ...12 ...
Page 13: ...13 ...
Page 15: ...15 ...
Page 16: ...16 All 4 buttons must be pressed at the same time ...
Page 21: ...Service Parts Breakdown ...
Page 22: ......
Page 23: ......
Page 24: ......
Page 25: ......