Incon TS-STS Quick Start Manual Download Page 4

Setup - Program the Console

2

SELECT MENU OPTION
 

SETUP

SETUP MENU

(MORE)

EXIT

SYSTEM

SUMPS

CLK/CAL

H

 U

MENU

Press the 

MENU key and follow

7

the highlighted sequence below
to view the Setup Menus

SETUP MENU

(MORE)

EXIT

SYSTEM

SUMPS

CLK/CAL

SETUP MENU

(MORE)

EXIT

SYSTEM

SUMPS

CLK/CAL

SETUP MENU

(MORE)

COM PORTS

Press the Down key 

▼ 

to see next display

Display

Menu Select Keys
(M1 – M4)

Keypad:
(Multi-Function,
Alphanumeric)

ACK SHIFT key

Report Printer
(thermal printer)

Na

Na

Na

Na

Navigating

vigating

vigating

vigating

vigating

Menus:

Menus:

Menus:

Menus:

Menus:

Push the 

UP/DOWN

keys 

 

to show

other menus or other
choices

Use menu keys

 (

M1

 to

M4

) to access menus

or to help edit text

Press the 

ENTER 

key

to make a setup choice
or to move down in the
menu 

tree

Press 

the 

CANCEL

key to cancel before
entry or to move up
and out of the menu
tree

Editing Text:

Press the 

M1 

key to move the cursor to the left 



Use 

M2 

to move the cursor to the right 

Use 

M4

 

to backspace & delete text to the left of the cursor 



Follow the highlighted sequence at left to program the
console.

Menus are in indented format (lower levels to the right).

The setup program  

factory default settings 

are shown

in ITALIC TEXT.  The console will auto-exit the setup
mode if no key is pressed after 3 minutes.

Minimum Setup Requirements

1)

From SETUP>SYSTEM (SYSTEM INFO), program the
System ID data and the No. (number of) Sumps

2)

SETUP>SUMPS>DATA>SUMP N>NAME>Sump Name (code-
name for each containment sump that will be leak tested)

3)

SETUP>CLK/CAL>Set Time  (input the correct time), Set Date
(input the correct date), Set Day (choose the day of the week)

ACK

SHIFT

a

b

KEY

#

1

2

3

Input
Alphanumeric
Text
(in setup mode):

Press the 

ACK

 SHIFT

key at the keypad

1

, or 

2

, or 

times to

cycle between the
unique key characters
(at positions 

1

2

, and 

3

).

Select and press a key
to input the desired
alphanumeric character.

M1

LEFT

M2

RIGHT

M3

M4

M1

LEFT

M2

RIGHT

M3

M4

M1

LEFT

M2

RIGHT

M3

M4

M1

LEFT

M2

RIGHT

M3

M4

M1

LEFT

M2

RIGHT

M3

M4

NOTES

Pg 4

Summary of Contents for TS-STS

Page 1: ...Federal and State regulations for leak limit and test time requirements Recommendations for locating the TS STS console outside of the Class I Division 1 Group D Hazardous Areas during testing are based on NFPA 30 NFPA 30A and NFPA 70 NEC TS STS Sump Test System Quick Start Guide INCON P N 000 3004 Rev D Feb 2009 www fraklinfueling com This document may change without prior notice INCON is a Regis...

Page 2: ... DISPENSOR SUMPS IN GROUPS SO OTHER DISPENSORS ARE LEFT IN SERVICE DURING TESTING GROUNDED 3 PRONG EXTENSION CORD REQ D SAFETY CONES DISPENSER 7 8 DISPENSER 5 6 Pg 2 SPLIT RING TS STS SUMP TEST SYSTEM SUMP TEST SYSTEM FLAT METAL ANGLE IRON REQUIRED TO SUSPEND PROBE SIDE VIEW TS STS STS PRB 12 LEAK TESTING PROBE WITH TSP SSP STAINLESS STEEL FLOAT DISPENSER SUMP WITH TEST SOLUTION Side View RECEPTAC...

Page 3: ...TH TSP SSP STAINLESS STEEL FLOAT TURBINE SUMP WITH TEST SOLUTION Side View POWER CORD WITH A GROUNDED 3 PRONGED PLUG 3 RECEPTACLES FOR FOUR SCREW IN PROBE CABLE PLUGS 1 2 4 SUMP TAPE WEIGHT DOWN CABLE TO PREVENT ACCIDENTAL MOVEMENT DURING LEAK TESTING PROBE CABLE PN 600 0200 50 FEET Turbine Sump 2 TS STS SUMP TEST SYSTEM GROUNDED 3 PRONG EXTENSION CORD REQ D SAFETY CONES BUILDING SUMP TEST SYSTEM ...

Page 4: ... left Use M2 to move the cursor to the right Use M4 to backspace delete text to the left of the cursor Follow the highlighted sequence at left to program the console Menus are in indented format lower levels to the right The setup program factory default settings are shown in ITALIC TEXT The console will auto exit the setup mode if no key is pressed after 3 minutes Minimum Setup Requirements 1 Fro...

Page 5: ...r the Business Name LINE 2 LOCATION LINE 2 input 24 characters Max INTELLIGENT CONTROLS INC Enter other Business data LINE 3 LOCATION LINE 3 input 24 characters Max P O BOX 638 Enter the Street Address LINE 4 LOCATION LINE 4 input 24 characters Max SACO ME 04072 Enter the City and Zip code LINE 5 LOCATION LINE 5 input 24 characters Max 1 800 984 6266 Enter the Business Number NO SUMPS enter total ...

Page 6: ...EEK Select the current day SUNDAY MONDAY TUESDAY WEDNESDAY THURSDAY FRIDAY SATURDAY 3 SYSTEM SUMP OKAY OKAY SYSTEM SUMP WARNING OKAY SYSTEM SUMP NO PAPER OKAY SYSTEM SUMP OKAY OKAY SYSTEM SUMP OKAY TEST LEVEL SUMP 1 SUMP 2 SUMP 3 SUMP 4 INCHES 2 01 3 09 1 76 3 12 SELECT FUNCTION 10 39 08 AM 10 29 2001 DISPLAY PRINTER SYSTEM SUMP OKAY LEAK Displays 1 Normal Display 2 Press the Check key to check th...

Page 7: ...on demand from the keypad The Sump Leak Test and Alarm Reports print automatically The other reports such as the Sump Level Reports Alarm Reports and Sump Test Reports can be printed on demand Press the menu select keys and choose the type of report that you wish to printout Alarm reports will print as soon as an alarm is detected Leak test reports print automatically after the leak test is finish...

Page 8: ...rt can be retrieved from the TS STS console through the communications port Comm Port 1 This port is located at the bottom side As with the printed reports this data is overwritten when a new test is run so it must be collected after each test The data can be stored in a database as opposed to saving the printouts For more information on this feature contact INCON Technical Service at 1 800 984 62...

Reviews: