Summary of Contents for D2501 EU

Page 1: ...Copyright 2021 InCoax Networks AB All rights reserved Confidential under NDA InCoax D2501 DPU Hardware User Manual InCoax D2501 EU InCoax D2501 UK InCoax D2501 US ...

Page 2: ...InCoax D2501 Copyright 2021 InCoax Networks AB All rights reserved Confidential under NDA Document History Date Rev Originator Description 2021 01 14 V 1 Helge Tiainen Initial version ...

Page 3: ... 4 Principal deployment model 7 5 Coaxial Network Use Cases 8 5 1 Coexistence with Terrestrial TV 47 694 MHz 8 5 2 Coexistence with Cable TV DOCSIS 3 0 10 5 3 Coexistence with Satellite 11 6 DPU Web Interface Access 12 6 1 Accessing the DPU Web Interface 12 7 Specifications 13 8 Legal Information 15 8 1 Regulatory Notice and Statement Class B 15 8 1 1 Canada 15 8 1 2 European Union 15 8 1 3 United...

Page 4: ...gure 4 Set up for the use case Terrestrial TV Star network 9 Figure 5 Set up for the use case Terrestrial TV US Home Run network 9 Figure 6 Set up for the use case Cable TV DOCSIS 3 0 Cascade network 10 Figure 7 Set up for the use case Cable TV DOCSIS 3 0 Star network 10 Figure 8 Set up for the use case Satellite 11 Figure 9 The DPU s panel connections 12 List of Tables Table 1 Abbreviations 1 Tab...

Page 5: ...e carrier frequencies PHY Physical Layer of the OSI model PPPoE Point to Point Protocol over Ethernet is a network protocol for encapsulating PPP frames inside Ethernet frames PON Passive Optical Network with its variants XGS PON GPON and EPON QAM Quadrature Amplitude Modulation is the name of a family of digital modulation methods and a related family of analog modulation methods widely used in m...

Page 6: ... to as the DPU in this document Customer End user or subscriber of broadband services Diplexer The in xtnd Combine diplexer is a series of high performance bidirectional frequency combiners i e for combining and splitting frequencies The combiners diplexers are used for connecting one or two MoCA Access broadband frequency spectrum signals from an in xtnd DPU with Radio TV frequency spectrum signa...

Page 7: ...Gbps max 3 2 Gbps aggregated on the RF port Quick Guide Quick Guide Warranty Warranty coverage Technical specification Disposal Recycling document Additional Information Power cord with EU plug order DPU with article D2501 EU If DC power feed 13 25VDC is used the Power Cord may be disconnected from power outlet if not used for back up power The cord can be detached from the Power Supply unit and d...

Page 8: ...as this may cause electric shocks Do not use in locations subject to high humidity or dust levels exceeding IP certification as this may cause damage to the equipment or start a fire Do not do anything that may damage the power cable When disconnecting the power cable pull on the plug body not the cable Do not damage a power cable make any modifications to it place heavy objects on top of it heat ...

Page 9: ...ont for the coax cables Connect a 75 ohm terminator F connector in all coax ports that are not used on the DPU Make sure that there are no insulating materials that can cover the DPU by accident Please also make sure that there are no corrosive liquids or materials that can emit any corrosive gases in the same room as the DPU 3 5 Storage Environment The ideal storage location is a dry and well ven...

Page 10: ... installed in or near the building the only required operation to connect new customers is to provide them with a Modem Please refer to the InCoax handbook System Design Guidelines for Cable Technicians for guidance As soon as the Modem has been connected to the coaxial network it will automatically be detected and configured by the DPU through the Management System if such setup has been enabled ...

Page 11: ... The Modem connects to any antenna outlet in the subscribers homes for easy self installation It communi cates with the DPU to get configuration parameters and connects to the subscribers Ethernet modem RJ45 port The firmware of the Modem can be upgraded from the DPU 4 4 Principal deployment model Figure 2 shows an example of the in building principal deployment model of D2501 Figure 2 Overview of...

Page 12: ...ed spectrum up to 862 MHz Band A AS 400 800 MHz co existence in satellite networks with spectrum up to 2150 MHz Band A B 800 1300 MHz co existence in TV networks with a spectrum up to 1300 MHz Band A C 1025 1675 MHz co existence in TV DOCSIS 3 0 networks with a spectrum up to 1800 MHz Band A D 1125 1675 MHz co existence in TV DOCSIS 3 0 networks with a spectrum up to 1800 MHz Band A E 1375 1675 MH...

Page 13: ...2501 Copyright 2021 InCoax Networks AB All rights reserved Confidential under NDA Figure 4 Set up for the use case Terrestrial TV Star network Figure 5 Set up for the use case Terrestrial TV US Home Run network ...

Page 14: ...DA 5 2 Coexistence with Cable TV DOCSIS 3 0 MoCA frequency band A D combined with Cable TV DOCSIS 3 0 in a Cascade Figure 6 and Star coaxial network Figure 7 Figure 6 Set up for the use case Cable TV DOCSIS 3 0 Cascade network Figure 7 Set up for the use case Cable TV DOCSIS 3 0 Star network ...

Page 15: ... InCoax Networks AB All rights reserved Confidential under NDA 5 3 Coexistence with Satellite High frequency Satellite TV signals combined with MoCA frequency band A A A AS See Figure 8 Figure 8 Set up for the use case Satellite ...

Page 16: ...al for a more detailed description of the web interface and how to set up the DPU See reference f 6 1 Accessing the DPU Web Interface Connect a computer with an Ethernet cable to the Management port on the DPU under the front cover marked MGMT RJ45 See Figure 9 InCoax recommends using the cable type CAT5e as a minimum for best performance Figure 9 The DPU s panel connections For best user experien...

Page 17: ...side enclosure 10 100 1000 Mbps configuration and statistics port RJ 45 connector supports type CAT5 UTP as a minimum One coax out with PG 11 F female connector 3 8 UNEF32 75 Ω F female connector 3 8 UNEF32 75 Ω for 13 25VDC power feed Indicators Power on Management Trunk Coax Link traffic and alerts External led indication on ZTP and system initiation and status Dimensions 257 203 100 mm W H D Wa...

Page 18: ...S 2 0 Security DHCP snooping Option 82 rewrite and trusted untrusted clients limit setting configurable options per VLAN Blocking of unknown CPE Broadcast storm protection from clients Support for PPPoE IA option 0x105 Remote ID Multicast IGMP snooping v2 v3 IGMP filtering per VLAN Configurable IGMP timeout Multicast VLAN Registration Bandwidth reservation per multicast group Max 256 Multicast gro...

Page 19: ...l interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user s own expense Caution Changes or modifications not expressly approved by the party responsible for the compliance could void the user s authority to operate the equipment 8 1 4 TUV SUD NRTL T...

Page 20: ...rical and electronic products and batteries should not be mixed with general household waste but taken to a designated collection site as indicated by the local authorities In accordance with national legislation and the WEEE Directives 2002 96 EC and 2012 19 EU and the Battery Directive 2006 66 EC amended by 2013 56 EU See reference s For more information about collection and recycling of old pro...

Page 21: ...og ul com standards en standard_94_6 j IEEE 802 1ad This was an Ethernet networking standard informally known as QinQ and was an amendment to the standard IEEE 802 1Q 1998 The IEEE 802 1ad was incorporated into the base standard IEEE 802 1Q in 2011 k IEEE 802 3 This is a working group and a collection of IEEE standards produced by the working group defining the physical layer and data link layer s...

Page 22: ...Directive 2011 65 EU became European Law in February 2003 ec europa eu environment waste weee index_en htm and eur lex europa eu legal content EN TXT uri CELEX 32012L0019 s Battery Directive 2013 56 EU This is an amendment to the Directive 2006 66 EC of the European Parliament and of the Council of 6 September 2006 on batteries accumulators waste batteries and accumulators https eur lex europa eu ...

Page 23: ...InCoax D2501 Copyright 2021 InCoax Networks AB All rights reserved Confidential under NDA InCoax Networks Europe AB Utmarksvägen 4 SE 802 91 Gävle Sweden sales incoax com Revision 1 0 www inxtnd com ...