3.4
Installation Environment
Install the
DPU
in a site free from strong electromagnetic field generators (such as motors), vibration, dust, and
direct exposure to sunlight.
Install the
DPU
in a cool and dry place for the acceptable temperature and humidity operating ranges.
See
section 7
on page 13 for the actual temperature ranges.
Install the
DPU
on a sturdy, level surface that can support at least 5 kg (11 lbs) of weight. Leave at least 10 cm
(4 inches) of space at the front for the coax cables.
Connect a 75-ohm terminator (F connector) in all coax ports that are not used on the
DPU
.
Make sure that there are no insulating materials that can cover the
DPU
by accident.
Please also make sure that there are no corrosive liquids or materials that can emit any corrosive gases in the
same room as the
DPU
.
3.5
Storage Environment
The ideal storage location is a dry and well-ventilated location, e.g. in a space with climate-control. Please refer
to
section 7
on page 13 for more details about the specified environmental storage conditions.
3.6
Theft and Vandalism
Depending on the circumstances for the installation it may be appropriate to mount the equipment (i.e.
the
DPU
,
Diplexers
and Switches) in a cabinet that can be locked securely.