background image

Fasten 

the supply water line

 securely so that there is no looseness.

* If it is loose, there is danger of water leakage.

Fasten the supply water line securely!

Manual Set

*The deodorizing cartridge has already 

been installed in the product.

Toilet Seat (Body)

Side Panel (left)

Side Panel (right)

Batteries (2)

Wood Screw

Plastic Anchor

Water Shutoff 

Valve

Water Supply 

Pipe

Hemispherical 

Face Plate

Water Supply Hose 

(400 mm)

Bracket

Remote Control 

Unit

Parts Check

 (Make sure all the parts are included in the packing box.)

Clip

AY Bolts for 

Mounting Parts

Washer

Mounting Base

Adjuster

(Contained in the bottom 

of the toilet bowl)

Flange

Gasket

Flange Nut

Washer

T-bolt

Mounting Nut

Decorator Caps (Large)
Nut
Washer
AY Bolts for Anchoring the Toilet
Washer

Installation Pattern Paper

Toilet

Fixing Fastener 

(pre-attached to the 

toilet bowl)

Available on request

600mm Part No.:322-1050

800mm Part No.:322-1049

Names of Parts

Shower Strainer

Toilet Seat

Water 

Shutoff Valve

Power Plug

Shutoff Valve

Flush Lever

Toilet Strainer

(See figure below.) 

Body

Water Supply Hose

Toilet Lid

Remote Control Unit

Nozzle (for posterior) 

Mounting Base

Nozzle (for bidet)

Shower Strainer 

(See figure below.)

Toilet Strainer

Drain Socket

Adjuster

Flange

Rating Label

Caution

Label

To your bottom-right from the front of the body

●Carry out the construction in order beginning with the water shutoff 

valve, then proceeding to the body.

●Make sure the distance to the 

soil pipe is within a range of 

200 and 580 mm. Match up 

the adjuster with the distance 

to the soil pipe, then cut it and 

connect it securely using PVC 

cement.

What is the distance to the soil pipe?

Positioning of water supply and drain pipes

Existing soil pipe

200 ~ 580

Adjuster

100

100

280

200~580

280

300 or more

330

Drain pipe 

(VP100, VU100, VP75, or VU75)

Water supply 1/2B 

(in case of supply from the wall)

Water supply 1/2B (in case of supply from the floor)

Remote 

Control Unit

Light Receptor

If the remote control unit is 

mounted on the left side wall

If it is necessary to mount the remote controller on the wall opposite to the remote controller receptor, 

be sure to confirm that it can receive signals from the installation location before mounting it.

If there is a washstand or other object installed on the side where the remote controller receptor is 

located and the remote controller needs to be mounted at a considerable distance from the toilet, the 

Satis may not be able to pick up remote controller signals. In such a case, install a screen that can 

reflect the signals within 1300 mm from the center of the toilet.

*Please prepare the screen on site.

The screen should be at least 1100 mm high and be wide enough to reach the position where the 

remote controller is mounted. (However, depending on the wall finish, color and other conditions, the 

size of the screen may differ somewhat, so please check to determine the best size.)

As much as possible, install the remote controller on the wall on 

the side where the remote controller receptor is located.

Remote Control Unit Mounting Location

If the remote control unit is 

mounted on the right side wall

1300 mm or less

Screen

Light Receptor

Remote 

Control Unit

Summary of Contents for SATIS DV-218-VH-W

Page 1: ...the user OBSERVE Lead water from a system that provides drinkable water If dirt or impure substances clogs the strainer install a filter to the water inlet OBSERVE Do not use a receptacle that is loos...

Page 2: ...h up the adjuster with the distance to the soil pipe then cut it and connect it securely using PVC cement What is the distance to the soil pipe Positioning of water supply and drain pipes Existing soi...

Page 3: ...ipe Water Supply Outlet Water Shutoff Valve Please note that the following installation steps 4 to 7 varies depending on the distance between the wall and the centre of the soil pipe If the distance i...

Page 4: ...onnect them See NOTE 4 Fixing the Drain Adjuster Flange and Mounting Base 1 Mount the gasket to the draining outlet of the flange and fix them on the existing flange with washers and flange nuts See N...

Page 5: ...B B C C A Fixing Part Washer C Holes AY Bolts for Anchoring the Toilet 6 to Existing Flange Flange Gasket AY Bolts for Anchoring the Toilet Washer Flange Nut Washer Drain Adjuster eps Gasket Drain Ou...

Page 6: ...pen State 2 Place the new mounting nuts on the mounting bolts See NOTE 17 Toilet Bowl Mounting Bolt Mounting Nut 3 Push up on the new mounting nuts to close them 4 Turn the new mounting nuts by hand t...

Page 7: ...ng the power plug again eps Power Plug Power Lamp Connect the product to a properly grounded outlet only There is danger of electric shock if a breakdown or current leakage occurs When a three slot re...

Page 8: ...gins spraying 3 Press the STOP button to stop the shower spray Since there is an occupied seat sensor the product s shower bidet and deodorizing functions will not operate if you don t touch the seat...