background image

PCW-1115-W(08100)

Installation Manual

DV-218-VH-W (GBC-941SU-AY)

●Use an receptacle with a 

maximum rating of AC 220 V and 1200 W

●The length of the power cord is 1.2 m. 

Install the receptacle so that it is within reach of the power cord and high enough from the floor so that water won't splash on it.

●Be sure to install a ground (Class 3 ground terminal construction).

* Ask an electrical contractor to install the wiring.

* Do not insert the power plug in the receptacle until installation is completely finished.

Doing so may cause system failure.

Power Supply

●Be sure to connect the water supply parts to the potable water line.

If surface water, industrial water or well water is used, it may cause 

deterioration of electrical and mechanical parts and lead to accidents. 

Water Supply

Water Pressure

●The minimum operating water pressure when 20 L/min. is 

flowing is 0.1 MPa {1.0 kgf/cm

2

} or greater. The maximum water 

pressure is 0.75 MPa {7.5 kgf/cm

2

} under hydrostatic pressure.

Even if other fixtures are used simultaneously, a supply water 

pressure of 0.1 MPa {1.0 kgf/cm

2

} or greater and less than 0.75 

MPa {7.5kgf/cm

2

} is required. If this minimum water pressure is 

not reached, pressure will be insufficient to operate the product’s 

cleaning functions. 

●The amount of space required for this toilet is shown in the following diagram.

At least 400 mm of clear space is required in front of the toilet in order for the 

open/close function of the non-touch toilet seat lid to operate correctly.

Minimum Installation Clearance

BE SURE TO FOLLOW 

THESE PRECAUTIONS AND 

INSTRUCTIONS

These safety precautions are essential for safe 

installation and use of the product. 
Please read the precautions thoroughly before 

installing the product. 

Explanation of Terms and Symbols

Absolutely do not allow anyone except 

an authorized service technician to 

disassemble, repair or modify this product. 

*There is danger of electric shock, or fire, causing injury.

 DON'T 

DISASSEMBLE

Do not use any power supply other 

than AC 220 V. Do not use any 

other method to connect the plug to 

an improperly configured receptacle.

*Use of exceeding the rated voltage could cause fire. 

FORBIDDEN

Thoroughly insert the power plug to 

the power point.

* Otherwise, it may cause fire or electrify 

the user.

OBSERVE

Lead water from a system that 

provides drinkable water. If dirt or 

impure substances clogs the strainer, 

install a filter to the water inlet.

OBSERVE

Do not use a receptacle that is loose and 

in which the plug does not fit snugly. 

*There is danger of electric shock or fire.

FORBIDDEN

Do not install or leave the main 

body or remote controller in a 

constantly humid location or 

location where water, liquid or 

splash may affect them.

FORBIDDEN

Do not pull out or insert the power 

plug with wet hands. 

*There is danger of electric shock.

 NO WET 

HAND

Do not pour water or cleanser 

inside or on the body and remote 

control, or on the power plug.

*There is danger of electric shock or fire.

 DON'T POUR 

WATER

●When removing the strainers, be sure 

to close the water shutoff valve.

●When installing the strainers, tighten if 

fully until the line is hidden by the body.

*Household articles may get wet if there is water leakage.

OBSERVE

Porcelain is breakable.

●Before installation, make sure the toilet 

bowl is not cracked or otherwise damaged.

●When installation is completed, check the toilet to 

make sure it has not been damaged during the 

installation work.

*Damaged parts could cause injury or water 

leakage and soaking in the bathroom.

OBSERVE

If freezing weather is anticipated 

before handing the product to the 

customer, keep the water drained out. 

*Freeze damage may cause water leakage or 

damage household articles.

OBSERVE

Be sure to adjust the water shutoff 

valve and check for water leakage 

after installation. 

*Household articles may get wet if there is water leakage. 

OBSERVE

Make sure that the earth wire is 

properly fixed. 

*Otherwise it may electrify the user in case 

of malfunction or a short circuit.

*Consult your electrician if there is no earth terminal 

around the power point.

EARTH

Do not nick, damage, carve, bend unduly, pull 

on, twist, bind or place heavy objects on top of 

the power cord, or pinch it between two objects.

 

*The above could damage the electrical conductors 

and cause electric shock or fire.

FORBIDDEN

1050 or more

425

400 or more

(mm)

 700 or 

more

WARNING

···

CAUTION 

···

NOTE       

···

Indicates a potentially hazardous situation which, if not avoided, 

could result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided, 

may result minor or moderate injury or in damage to other 

property.
Indicates a potentially hazardous situation, if not avoided, may 

result in damage to other product.

 WARNING

 CAUTION

Summary of Contents for SATIS DV-218-VH-W

Page 1: ...the user OBSERVE Lead water from a system that provides drinkable water If dirt or impure substances clogs the strainer install a filter to the water inlet OBSERVE Do not use a receptacle that is loos...

Page 2: ...h up the adjuster with the distance to the soil pipe then cut it and connect it securely using PVC cement What is the distance to the soil pipe Positioning of water supply and drain pipes Existing soi...

Page 3: ...ipe Water Supply Outlet Water Shutoff Valve Please note that the following installation steps 4 to 7 varies depending on the distance between the wall and the centre of the soil pipe If the distance i...

Page 4: ...onnect them See NOTE 4 Fixing the Drain Adjuster Flange and Mounting Base 1 Mount the gasket to the draining outlet of the flange and fix them on the existing flange with washers and flange nuts See N...

Page 5: ...B B C C A Fixing Part Washer C Holes AY Bolts for Anchoring the Toilet 6 to Existing Flange Flange Gasket AY Bolts for Anchoring the Toilet Washer Flange Nut Washer Drain Adjuster eps Gasket Drain Ou...

Page 6: ...pen State 2 Place the new mounting nuts on the mounting bolts See NOTE 17 Toilet Bowl Mounting Bolt Mounting Nut 3 Push up on the new mounting nuts to close them 4 Turn the new mounting nuts by hand t...

Page 7: ...ng the power plug again eps Power Plug Power Lamp Connect the product to a properly grounded outlet only There is danger of electric shock if a breakdown or current leakage occurs When a three slot re...

Page 8: ...gins spraying 3 Press the STOP button to stop the shower spray Since there is an occupied seat sensor the product s shower bidet and deodorizing functions will not operate if you don t touch the seat...

Reviews: