background image

MODEL CODE/S

E S L 6 0 D 2 S

60cm Slideout  

Rangehood 

V 2 . 0   |   0 5 2 2

U S E R   M A N U A L

I N A L T O . H O U S E

F O R   A L L   A U S T R A L I A N   H O M E S

Summary of Contents for ESL60D2S

Page 1: ...MODEL CODE S ESL60D2S 60cm Slideout Rangehood V 2 0 0 5 2 2 U S E R M A N U A L I N A LT O H O U S E F O R A L L A U S T R A L I A N H O M E S...

Page 2: ...ms are there to ensure you get the most out of your appliance Should you want to learn more about recommended usage the various features of your appliance and importantly taking care of the unit when...

Page 3: ...nformation at hand which can be found on your appliances rating plate Model Number Serial Number Customer Care Contents 2 Welcome 4 Safety Information 8 Your InAlto Rangehood 11 Operation Instructions...

Page 4: ...ehood must only be installed in accordance with the instructions provided Incorrect installation may cause harm to persons damage property and void the product s warranty Read the following carefully...

Page 5: ...There shall be adequate ventilation of the room when the range hood is used at the same time as appliances burning gas or other fuels not applicable that only discharge the air back into the room Regu...

Page 6: ...st flue installation The following rules must be strictly followed to obtain optimal air extraction Keep exhaust flue short and straight Do not reduce the size or restrict exhaust flue Keep bends in t...

Page 7: ...t of reach of children DISPOSAL OF THE APPLIANCE Old appliances should not simply be disposed of with normal household waste and should be delivered to a collection and recycling centre for electric a...

Page 8: ...ehood features switch controls with 2 speed levels of extraction KEY 1 Rangehood housing 2 Slide out Front Fascia Rail 3 Inner Aluminium Grease Filter 4 Outer Aluminium Grease Filter 5 On Off Switch 6...

Page 9: ...TIONAL ITEMS REQUIRED FOR INSTALLATION Duct tape or cable ties Ducting relevant to your installation requirements including any rigid bends vents and or adapters Drill and or screwdriver Spirit Level...

Page 10: ...10 THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 11: ...el is pulled back out the rangehood will start working at the previously set level OPERATING INSTRUCTIONS NOTE Operation Instructions Controls OPERATING YOUR RANGEHOOD When the rangehood is plugged up...

Page 12: ...rangehood s rating label located within the rangehood behind the aluminium grease filters into the form on page 23 This will be helpful should you need to contact our service team in the future POSITI...

Page 13: ...ew rangehood is undamaged and in good working order The carton is recyclable Whenever possible reuse the carton and recycle it when disposing of the packaging materials Plastic wrapping can be a suffo...

Page 14: ...pipe not supplied to the outlet on the top of the rangehood and vent to external air It is recommended that the ducting pipe is 120mm in diameter Installation Instructions Continued 10 White Plastic C...

Page 15: ...lectrical hazards Figure 7 Rear mounting to the wall Using a spirit level mark a horizontal line on the wall where the rangehood base will be observing all necessary clearances Fig Check the required...

Page 16: ...ottom of the cupboard and secure it in place with four ST4x30mm screws Fig If there is a space between the wall and the rear of the rangehood install the rear underside support mounting bracket Part I...

Page 17: ...17 THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 18: ...ecommend washing the Aluminium filters within a dishwasher This can damage the filter and cause a discolouration of the filter EXTERIOR SURFACES Clean surfaces using non abrasive cleaning products tha...

Page 19: ...ull out the lamp connecting lines together Open the protection cover as shown in the picture below and unplug the connected plastic shell to replace a new lamp Open the protective cover Unplug the lin...

Page 20: ...pear on the warranty card at the rear of this user manual FAULT POSSIBLE CAUSE COMMON SOLUTIONS The extractor fan ceases to function There is no electrical current in the network Check with other appl...

Page 21: ...06 A2 2007 A3 2009 A4 2010 for electrical safety and with EN 55014 1 2006 A1 2009 A2 2011 for electromagnetic compatibility Responsible disposal At the end of their working life do not throw any of th...

Page 22: ...22 to this page Attach your receipt...

Page 23: ...ating plate located within the rangehood behind the aluminium grease filter installation details and purchase details which can be found on your sales invoice Purchase Details STORE DETAILS STORE NAME...

Page 24: ...having purchased the Appliance for re sale and your has a corresponding meaning 2 This warranty only applies to Appliances purchased and used in Australia and is in addition to and does not exclude r...

Page 25: ...jor failure The benefits to you given by this warranty are in addition to your other rights and remedies under a law in relation to the Appliances or services to which the warranty relates 11 At all t...

Page 26: ...THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 27: ...ccident negligence alteration misuse or incorrect installations f a product dismantled repaired or serviced by any serviceman other than an authorised service agent g a product not in possession of th...

Page 28: ...D E S I G N E D I N M E L B O U R N E F O R A L L A U S T R A L I A N H O M E S W W W I N A LT O H O U S E...

Reviews: