background image

3. 

Close cold water supply.

4. 

Drain the cold water from tank through MFV drain pipe by lifting the drain lever, remove 
flexible pipe.

5. 

Remove the water heater from the wall mounting bracket, after water heater is emptied.

6. 

Remove the decorating cover, unscrew the heating assembly flange.

7. 

Clean the container and the heating element assembly to remove scale formation, by 
using a suitable acid or by gently scraping the scale. Check the heating element surface 
after cleaning for "No Surface Damage".

8. 

Replace Magnesium anode in case it is worn out.

9. 

Remount the heating assembly flange. Ensure the internal wiring connection are made 
as per the wiring diagram shown in the manual.

10. 

Hang the water heater on the wall mounting bracket provided on the wall. Move the 
water heater down-ward to ensure that it is seated on bracket properly.

11. 

Open cold water supply until water flows without interruption form outlet valve.

12. 

Close the outlet valve and check for "No eventual leakage" around the flange and water 
connections.

13. 

When there is no leakage, then switch on electric supply.

Do's

1.

 

The gate valve at the inlet should always be kept open.

2. 

To minimize scaling of heating element & the tank, (which takes place rapidly in areas of 
hard water), drain the water from heater unit periodically. However get this done through 
a qualified technician/plumber only.

3. 

Always get the water heater serviced once in a year from a INALSA authorized service 
representative.

4. 

Use genuine spares when spares replacement is necessary.

5. 

Switch OFF the power supply to the unit & drain out the water when not in use for a 
longer period of time. This prevents scaling of the element.

6. 

In case both the lamps do not glow, do not start the unit by resetting the thermal cutout. 
Instead contact the nearest customer care centre.

Don'ts

1. 

Safety devices like safety valve, thermostat, thermal cut - out etc are pre-set from factory 
& sensitive devices. Do not tamper with them, this could be hazardous.

2. 

Do not switch ON the heater till it is completely filled with water.

3. 

In case you observe any abnormality of operation immediately switch OFF the main 
power supply to the unit and contact the nearest customer care centre.

4. 

Never install a pressure reducer valve at the inlet.

9

Summary of Contents for PSG 15GL

Page 1: ...Instruction Manual...

Page 2: ...kers and Electric Chimneys Your newly acquired INALSAStorage Water Heater bears thesamedistinctivehallmarkof excellence It is all the result of vigorous quality consciousness in INALSA s design and de...

Page 3: ...ageinVolts frequencyinHz 230V 1Ph 50Hz AC Ratedpowerinputinwatts 800 1200 2000 RatedInputCurrentinAmps 8 7 Meanhotwateroutputtemp C 60 RatedpressureinMpa 0 8 Standingloss inKWH 24hrs 45 C 0 569 0 693...

Page 4: ...anode rod protectstank fromcorrosion Withsteelcore magnesiumanoderodprotectsenameledtankfromrustandcorrosion 3 SS 800 Glasslinedheatingelement High quality heating element offers superior heating perf...

Page 5: ...ange The indicator lamp provided with this circuit glow and un glow during cut in and cut off This shows the proper working of the thermostat Thisdeviceisprovidedwithanadjustableknobtosetthedesiredwat...

Page 6: ...nting bracket bracket supplied withwaterheater of minimumdepth100mm 2 Fillupthecompletedigup spacewithcementconcrete 3 Ensurecementconcreteisproperlycured set 4 Then thewallbracketcanbefixedwiththehel...

Page 7: ...eater and bathroom fittings use metal flexiblepipe 4 Coldwaterinletismarkedblueandhotwateroutletis markedwithred 5 First fixthemultifunctionvalve MFV toinletof waterheater 6 Connectcoldwaterinlettothe...

Page 8: ...ertapopen Now filltheheaterbyopeningthecontrolvalveattheinlet 3 When the heater is full water will start flowing through the hot water tap Close the hot watertap 4 Now the heater will always have wate...

Page 9: ...mage 6 To increase the life of heating element de scaling should be done periodically with the assistanceofthenearestauthorisedservicecenter If thewaterheateris not goingtobe used foralong time a Plug...

Page 10: ...s 13 Whenthereisno leakage thenswitchon electricsupply Do s 1 Thegatevalveattheinletshould alwaysbekeptopen 2 To minimize scaling of heating element the tank which takes place rapidly in areas of hard...

Page 11: ...eraturetobehigh overlow 3 Temperature controller Inviteauthorisedservicetechnicianto malfunction repairthewaterheater 4 Theheatingelement failure 1 Haltingthetapwater Awaitingthetapwatertoprovidethe w...

Reviews: