If you encounter any unexpected noise or rough motor operation, disconnect the equipment from the power 

supply and check its state. Repairs shall be given to authorized IN-ECO service centers.

 

6.2  M

AINTENANCE

 

Disconnect the equipment from the power supply to avoid electric shock. Ensure the equipment will not re-

peatedly start upon reconnection to the power supply. Do not perform maintenance work if the equipment is 

heated up to operating temperature. 

 

Check and replace the following regularly: 

>

 

air filter in the intervals specified by the supplier, 

>

 

bearings* in the equipment. 

 

*)  The minimum service life of bearings is 15,000 operating hours, providing the operating conditions are 

respected. The replacement of bearings shall be given to authorized IN-ECO service centers. Keep the report 

from the bearings replacement. 

 

When disconnecting the equipment from the pipes, close the suction and discharge branch with a plastic co-

ver, which was supplied or in some other manner. During maintenance, prevent any objects from entering the 

blower or pipes. 

 

After maintenance, or repair, prior to start-up, proceed according to the instructions in section 5.1 Start-up. 

6.3  S

TORAGE

 

Keep the INW blowers/pumps in a dry environment with normal air humidity. For a relative humidity of 80% or 

higher, store in a closed package with a drying agent. 

7  S

ERVICE

 

Repairs shall only be carried out by an authorized IN-ECO service center during the warranty period. All war-

ranty rights are forfeited if the equipment is tampered with during the warranty period. Have an authorized IN-

ECO service center service INW ring blowers / vacuum pumps after the warranty has expired. 

8  Accessories 

Use original accessories with INW blowers/pumps with side channel. Contact the authorized IN-ECO service 

center for the specifications and supplies of accessories (for example: air filters, safety valves, manometers, 

backflow valves, flowmeters). 

8.1  A

IR FILTER

 

The air filter should be installed as close to the suction branch as possible to protect the equipment against 

solid objects, dust, cellulose, etc. Do not start the equipment without an air filter. The filter should not let parti-

cles larger than 40 μm through. 

Use a filter with sufficient capacity so the pressure loss is adequate. 

Original air filter 

The air filter (filtration insert) must be cleaned no later than after 250 operating hours and the filtration insert replaced no 

later than after 3,000 operating hours. The authorized IN-ECO service center will supply the filtration insert. 

Removal:  

a)  blower filter / unscrew the wing nut. Remove the protective cover and take out the filtration insert. 

b)  pump filter / release the closing pins of the filter lid. Remove the filter lid and take out the filtration insert. 

Clean the filtration insert (blow and manually dust) and replace if necessary. 

Assembly: in reverse order. 

The filtration insert of the air filter must be cleaned or replaced more frequently depending on the level of medium impuri-

ty. Performance becomes impaired with insufficient maintenance of the air filter and with it the service lift is shortened.

 

8.2  S

AFETY VALVE

 

Install a safety valve to prevent from overloading the equipment and subsequently shortening its service life.

 

The safety valve must be configured for the maximum working pressure. This way the equipment will be pro-

Summary of Contents for INW Series

Page 1: ...his manual carefully before using the product INW blowers pumps comply with the conditions of Europe an Union directive 2002 95 ES issued by the European Parliament and Commission dated January 27 2003 on the Restriction of the use of certain Hazardous Substances in electrical and electronic equipment INW blowers pumps comply with the Eu ropean Community directive for mechani cal equipment ...

Page 2: ...discharge gases 6 4 Installation 7 4 1 Handling moving transporting 7 4 2 Assembly 7 4 3 Installation 8 5 Operation 9 5 1 Start up 9 5 2 Operation 9 6 Maintenance 9 6 1 Inspection 9 6 2 Maintenance 10 6 3 Storage 10 7 Service 10 8 Accessories 10 8 1 Air filter 10 8 2 Safety valve 10 8 3 Manometer 11 8 4 Backflow valve 11 Recommended installation of the INW blower pump with accessories 11 9 Waste d...

Page 3: ...em Gas Within the scope of this manual gas is considered as pure gas or a mixture of gases In practice this is usu ally air Authorized IN ECO service Within the scope of this manual authorized IN ECO service is considered the service center of IN ECO spol s r o For more details contact information visit www in eco eu 1 2 DESCRIPTION OF INW BLOWERS PUMPS Fig 1 Assembled INW blowers pumps A single s...

Page 4: ...can work on the electrical equipment and must observe all relevant standards while doing so Prior to starting work on the electrical equipment disconnect the power supply ensure the equipment cannot be switched on again check that the power supply is disconnected cover or enclose neighboring live parts Open the terminal box cover only after you have checked that the power supply has been disconnec...

Page 5: ... of equipment at www in eco eu However after installing the equipment the total noise level in the workplace can exceed 85 dB In this case designate the zone with an increased noise level use hearing protection 3 Use 3 1 GENERAL This manual applies to the INW ring blower vacuum pump with a side channel single stage and multi stage with a single phase and three phase motor It contains safety inform...

Page 6: ...cessary for example if you use the equipment in a small area or within a soundproof housing ensure the necessary air circulation e g using a ventilator Air gas temperature and humidity The INW ring blower vacuum pump are designated for use in ambient temperatures ranging from 30 C to 40 C The optimal ambient operating temperature is 0 C to 25 C When used in an environment with a tem perature excee...

Page 7: ...ing this label 4 INSTALLATION 4 1 HANDLING MOVING TRANSPORTING Use sufficient personal protective equipment when handling the equipment The equipment may have sharp edges Equipment weighing 30 kg or more includes lifting loops screwed Use adequate lifting and handling equipment pulleys cranes etc When moving and transporting the equipment make sure the equipment is sufficiently anchored to avoid u...

Page 8: ...o the specifications stated in the catalog sheets also available on the www in eco eu website The equipment is supplied without connecting electric wires Use electrical wires of the proper strength section according to the electrical specifications for the specific blower pump stated in the catalog sheets on the www in eco eu website The wiring diagram is on the cover of the terminal box First con...

Page 9: ...ed as 10 Prevent any liquids or solid objects from entering the equipment Use an air filter with a permeability less than 40 μm The maximum possible pressure difference in the system must not be greater than the maximum pressure difference of the equipment stated in the catalog sheet on the www in eco eu website or on the product label Otherwise the equipment is critically overloaded The common op...

Page 10: ...h during the warranty period Have an authorized IN ECO service center service INW ring blowers vacuum pumps after the warranty has expired 8 Accessories Use original accessories with INW blowers pumps with side channel Contact the authorized IN ECO service center for the specifications and supplies of accessories for example air filters safety valves manometers backflow valves flowmeters 8 1 AIR F...

Page 11: ...E A backflow valve can be installed to increase the protection of the equipment against the reverse suction of liquid into the equipment RECOMMENDED INSTALLATION OF THE INW RING BLOWER VACUUM PUMP WITH ACCESSORIES The diagram of the recommended single stage INW blower pump with accessories is shown on figures 1 Blower pump 2 Air filter 3 Manometer 4 Safety valve 5 Backflow valve Fig 4 Blower with ...

Page 12: ...c made in connection with normal service are not covered by this Warranty The following must be included when returning the INW ring blower vacuum pump 1 sales receipt warranty 2 description of how the equipment is used and the issue 3 contact information address phone number e mail etc Equipment returned or submitted for repair must be delivered clean Costs on transporting the equipment to the au...

Reviews: