Installation
13
Driveline and Pump Installation
The pump may be driven using a driveline rather than directly mounting to the PTO. The
following steps are a guide in this application.
NOTE
Before installing driveline, refer to instructions for proper driveline installation techniques.
1
Install the PTO (
see instructions
).
2
Loosely bolt the pump mounting bracket to the adjustable bracket.
3
Bolt the adjustable bracket to the frame at a point that will not exceed 48" (122cm) from the
PTO and will not cause a joint angle greater than 8°.
4
Check the pump rotation. Install pump, pump end yoke and PTO end yoke.
5
Size, cut and weld the driveline to the necessary length. Ensure driveline balance and run
out meet specification. Allow 1" (2.54 cm) extra for PTO end yoke.
6
Install driveline in phase with proper operating angle calculations. Lock set screws. Grease
U-joints and mating spline.
7
Ensure all mounting bolts are tight.
DANGER
70392891
Keep clear of rotating drive shaft.
Never work on or near an installed
power take-off or driveline with the
engine running.
CONTACT WITH A ROTATING DRIVELINE
WILL CAUSE
KEEP AWAY
DEATH OR SERIOUS INJURY
WARNING!
AVOID DEATH OR SERIOUS INJURY! The driveline installer must inspect the
final position of the driveline to determine whether an operator or other personnel are
protected from rotating driveline hazards. If the protection is insufficient, a guard MUST be
installed. Contact IMT for information on installing a guard.