70735257 SII Handheld Remote
7
Section - 3
Pistol Grip (Handheld) Remote Special Considerations
•
Inactivity timeout is ten (10) minutes
•
Pistol grip input power for non-RF mode is +12VDC.
•
Function switch must be engaged before the proportional trigger can be used.
Power Up the Pistol Grip (Handheld) Remote
To activate (turn on) the pistol grip remote, twist the STOP button UP (clockwise) and then hold S1 UP until the
LEDs flash and the TX begins to rapidly blink (approximately one-second). Release S1. Normal system operation
is indicated by LEDs TX and RX rapidly blinking.
Associate Mode
The pistol grip (handheld) remote (70735257) allows 1-to-1 association to a receiver base unit (70735258). To
associate there must be a clear line of sight between the handheld and the base, and both units must be OFF
(powered down). Association cannot occur while in non-RF mode. The pistol grip remote is powered down by
depressing the oversized mushroom-style STOP button or by actuating S1 DOWN. The base unit is powered
down by removing P1 and P2 connectors, or by removing the source power from the unit.
***DO NOT OPERATE THE TRIGGER WHILE ASSOCIATING***
1. Stand near the Base Unit ( in line of sight)
2. Twist the MACHINE STOP button clockwise to the UP
position.
3. Hold simultaneously switches S1 UP and S7 UP
4. All four (4) LEDs will light. When all but the TX go out
and is blinking, continue to hold S1 UP and S7 UP.
5. Power up the Base Unit.
6. Release S1 and S7.
Handheld and Base Unit association is complete when TX
and RX continue to blink (flicker) when the switches are
released.
S7
S1
assoc
T
X ON
TX OFF
LOW
store
AIR OFF
WSMB-1
1002
70735257
assoc
TX
RX
ER
BA
06/15/2022