IMT 70735257 Manual Download Page 1

IOWA MOLD TOOLING CO., INC.

P.O. Box 189

Garner, IA 50438

Tel: 641.923.3711

Fax: 641.923.2424

www.imt.com

SII Telescopic 

Proportional Electric Crane

Radio Remote

Revised: 06-15-2022

© 2022 Iowa Mold Tooling Co., Inc.

All rights reserved

No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form 

or by any means, electronic, mechanical, photocopying, recording or otherwise without the prior written 

permission of Iowa Mold Tooling Co., Inc.

Iowa Mold Tooling Co., Inc. is an Oshkosh Corporation Company

Manual # 91728497

Summary of Contents for 70735257

Page 1: ...022 2022 Iowa Mold Tooling Co Inc All rights reserved No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photoc...

Page 2: ...a to cause cancer and birth defects or other reproductive harm To minimize exposure avoid breathing exhaust do not idle the engine except as necessary service your vehicle or equipment in a well venti...

Page 3: ...damentals 8 MIN MAX Adjustment Procedure for 70735257 70735258 8 Battery Installation 11 Battery Installation Replacement 12 70735258 SII Base Receiver 13 70735258 SII Receiver Radio Remote Base Unit...

Page 4: ...iv...

Page 5: ...Introduction 1 Section 1 Introduction Section 1 06 15 2022 SII Telescopic Proportional Electric Crane Radio Remote...

Page 6: ...llow all safety information and instructions contained in this manual and on the equipment as well as any requirements of local state and federal law industry standards and any other applicable safety...

Page 7: ...List of Equipment 3 Section 2 List of Equipment Section 2 06 15 2022 SII Telescopic Proportional Electric Crane Radio Remote...

Page 8: ...REM S2 ELECTRIC 1 70735257 PG 2H14 11002 70735258 BU 2H20XF 11002 assoc TX ON TX OFF WSMB 11002 70735257 assoc TX RX ER BA store TO LOAD 70735260 V1 V2 V3 HTH RTX RRX CTX CRX OUT IN ERR OUT BU 2H20XF...

Page 9: ...70735257 SII Handheld Remote 5 Section 3 70735257 SII Handheld Remote Section 3 06 15 2022 SII Telescopic Proportional Electric Crane Radio Remote...

Page 10: ...E USER BATT BATTERY AMBER LED 4 CYCLE ON OFF CHANGE BATTERIES SWITCH LOCATION LABEL SWITCH STYLE STOP MACHINE STOP MAINTAINED TRIGGER NONE MOMENTARY SW7 CONFIGURATION SW6 NOT USED SW1 UP TX ON SW1 DOW...

Page 11: ...and the base and both units must be OFF powered down Association cannot occur while in non RF mode The pistol grip remote is powered down by depressing the oversized mushroom style STOP button or by...

Page 12: ...unction switches on the unit Releasing the function switch used to enter trigger adjustment MIN MAX Adjustment Procedure for 70735257 70735258 1 Turn the controller on by twisting the red STOP button...

Page 13: ...ivating switch S7 down toggles between MIN and MAX while in Adjust Mode Exit Adjustment Mode either by Releasing all switches including the trigger and waiting for the handheld to time out Pressing th...

Page 14: ...This page left intentionally blank 10 06 15 2022 SII Telescopic Proportional Electric Crane Radio Remote...

Page 15: ...Battery Installation 11 Section 4 Battery Installation Section 4 06 15 2022 SII Telescopic Proportional Electric Crane Radio Remote...

Page 16: ...the handheld 3 Install or replace with four 4 fresh size AA alkaline batteries Observe the proper polarity by positioning the batteries as indicated in the battery compartment 4 Replace the compartme...

Page 17: ...70735258 SII Base Receiver 13 Section 5 70735258 SII Base Receiver Section 5 06 15 2022 SII Telescopic Proportional Electric Crane Radio Remote...

Page 18: ...4 CAN TX 5 CAN RX 6 OUPUT ACTIVE 7 INPUT ACTIVE 8 ERROR 70735260 V1 V2 V3 HTH RTX RRX CTX CRX OUT IN ERR OUT BU 2H20XF 11003 An Oshkosh Corportation Company 70735258 BU 2H20XF 11002 70735258 BU 2H20XF...

Page 19: ...S M ROTATE CLOCKWISE S5 DIGITAL 1 RED BLK M6 LO HS M ROTATE COUNTER CLOCKWISE S5 DIGITAL 2 ORG BLK M7 LO HS M PUMP S2 or S4 or S5 DIGITAL 3 WHT BLK M8 NOT USED DIGITAL 4 GRN BLK M19 NOT USED DIGITAL 5...

Page 20: ...ON FOR CAN MESSAGING BETWEEN PG AND BU BASE UNIT SAFETY LINK WHEN ANY OF THE FOLLOWING OCCURS MACHINE STOP IS PRESSED HANDHELD UNIT GOES OUT OF RANGE HANDHELD UNIT DE ACTIVATES DUE TO LOSS OF POWER IN...

Page 21: ...MODULATION DSSS FREQUENCY HOPPING TECHNOLOGY ANTENNA INTERNAL ENCLOSURE DIMENSIONS MM 133 X 118 X 36 INCH 5 25 X 4 7 X 1 4 DURABILITY HIGH IMPACT POLYMER CASE LED INDICATORS 1 HEALTH BLINKS 1X SEC WH...

Page 22: ...This page left intentionally blank 18 06 15 2022 SII Telescopic Proportional Electric Crane Radio Remote...

Page 23: ...LED Troubleshooting 19 Section 6 LED Troubleshooting Section 6 06 15 2022 SII Telescopic Proportional Electric Crane Radio Remote...

Page 24: ...RE ASSOCIATE THE REMOTE UNIT TO THE BASE UNIT OUT LED NOT ACTIVE CHECK THAT THE REMOTE UNIT LEDs ARE ACTIVE WHEN THE APPROPRIATE BUTTONS ARE PUSHED ERR LED ACTIVE OVER TEMPERATURE OR OVER CURRENT CHAN...

Page 25: ...Identification Locations Exposure 21 Section 7 Identification Locations Exposure Section 7 06 15 2022 SII Telescopic Proportional Electric Crane Radio Remote...

Page 26: ...harness on the torso Equipment containing the radio module was evaluated for RF exposure hazards by two approaches 1 Maximum Permissible Exposure MPE for mobile applications 2 Specific Absorption Rat...

Page 27: ...TE THE BASE UNIT AGENCY LABEL POSITION IS IDENTICAL FOR ALL INTERNAL ANTENNA AND EXTERNAL ANTENNA BASE UNITS Model BU 2H20XF 11002 Contains FCC ID LOBSRF305 IC 7955A SRF305 Input 9 365 3A per channel...

Page 28: ...This page left intentionally blank 24 06 15 2022 SII Telescopic Proportional Electric Crane Radio Remote...

Page 29: ...red trademarks of Iowa Mold Tooling Co Inc Garner IA USA 2022 Iowa Mold Tooling Co Inc All Right Reserved IOWA MOLD TOOLING CO INC P O Box 189 Garner IA 50438 Tel 641 923 3711 Fax 641 923 2424 www imt...

Reviews: