27
PULSEMIG 300-T2
EN
Push Pull torch (OPTION)
The Push Pull torch is connected to the connector (3).
Using a Push Pull torch will enable the use of AlSi wire even Ø 0.8 mm with a 4m
torch (ref. 044111). This torch can be used on any mode.
The detection of the Push-Pull torch is made by a simple press on the trigger.
When using a potentiometer controlled push-pull torch, the interface’s settings
allow you to set the maximum value of the adjustment range.
The torch’s potentiometer can then be used to adjust between 50% and 100% of
this value.
Connection diagram for Push
Pull torch with potentiometer
(10 kΩ)
1
3
4
7
8
10
+4
-5
+Pot 10
-Pot 3
R
2
+
-
1
8
M
1
3
2
5
4
The digital torch works as follow:
1- Green light (speed:
)
2- Push button: Setting choice
3- Orange light (arc height:
)
4- Incrementing (speed or arc according to button 2)
5- Decrementing (speed or arc according to button 2)
Spool Gun torch (OPTION)
The Spool Gun torch is connected to the connector (7). This torch can be used
only in synergic, standard and manual mode.
- In manual mode (see p.20), the knob to adjust the wire speed is on the torch
(adjustment cannot be done on the machine).
- In synergic mode (see p.20), the adjusting knob enables to amend the wire
speed between 50% to 100% of the interface value.
The detection of the Push-Pull torch is made by a simple press on the trigger.
Make sure to adjust the max speed wanted with the dial on the interface.
Procedure of reel assembly on
Spool Gun torch
4
5
1
2 3
1- Button opening/closing casing
2- Reel tightening nut
3- Reel break nut (do not tighten too much)
4- Adjsutment screw for rollers tension
5- Adjustment knob for speed wire
- Open the case (1), remove the support nut (2).
- Untighten the reel brake nut (3).
- Insert your reel.
- To insert the wire in the rollers, put a tension on the «adjustment screw for rollers
tension (4)»
- Remove the torch wire by reeling the reel.
- Plug in the Spool gun command connector and power connector (see p.2).
RESET
The PULSEMIG has 2 reset options. The « SOFT » option resets the ma
-
chine completely but stores the settings saved in memory. The « TOTAL »
option reset the machine perameters to those when purchased (For this
mode an SD card is needed).