IMS 171707 Operator Instructions Download Page 4

Model 3300 Controller Programming 

Instructions

To Program the Set Point Temperature:

1. Press and hold the “

*

” button.

• “

°F

” and the temperature flash back and forth in the display

2. While holding the “

*

” button, press      button to move set 

point temperature up, or press     button to move set point 
temperature down

•  Holding the      or      button while holding the “

*

” button 

will change the temperature continuously

•  Quickly pressing the      or      button while holding the “

*

” 

button will change the temperature in 1-degree increments 
with each press

3. After you reach the desired set point temperature, release the 

*

” button; your set point temperature is now programmed.

Note: The current thermocouple temperature is displayed.

To Lock the Set Point Temperature:

After you set the temperature, you can lock it by following 
the instructions below:

1. Press and hold both      or      buttons together until “tune” is 

displayed, then release both buttons.

  • The word “tune” and the word “off” flash back and forth in   

    the display

2. Press the      button until you see “SP.Lk” in the display.

• “SP.Lk” and the word “off” should be flashing back and 

forth in the display

3. When “SP.L” is displayed, press and hold the “*” button and 

the      or      button to select off or on.

4. Select “on” and release the “

*

” button; the set point is now 

locked.

5. Press and hold the      or      buttons together until the 

thermocouple temperature is displayed, then release the 
buttons.

6. To verify that the set point is locked, press and hold the “*” 

button, and while holding the “*” button, quickly press either 
the      or      button.

• If the set point is locked, the temperature will not move
• If the temperature changes, repeat steps 1-5

To Reset Controller:

1. After the unit detects a leak, the audible alarm and LED will 

activate and remain on until the controller is reset. 

  Caution: Only reset controller after the leak is fixed.

2. Before the temperature can be reset, the temperature of the 

thermocouple displayed on the controller must be below the 
set point temperature; the controller cannot be reset until this 
happens.

3. To reset the controller, press the      and      buttons together 

and release quickly. The controller will reset and both audible 
alert and LED will turn off.