background image

 

 

30-39 

Built-in static pattern effect 3 

40-49 

Built-in static pattern effect 4 

50-59 

Built-in static pattern effect 5 

60-69 

Built-in static pattern effect 6 

70-79 

Built-in static pattern effect 7 

80-89 

Built-in static pattern effect 8 

90-99 

Built-in static pattern effect 9 

100-109 

Built-in static pattern effect 10 

110-119 

Built-in static pattern effect 11 

120-129 

Built-in static pattern effect 12 

130-139 

Built-in static pattern effect 13 

140-149 

Built-in static pattern effect 14 

150-159 

Built-in static pattern effect 15 

160-169 

Built-in static pattern effect 16 

170-179 

Built-in static pattern effect 17 

180-189 

Built-in static pattern effect 18 

190-199 

Built-in static pattern effect 19 

200-209 

Built-in static pattern effect 20 

210-255 

Static pattern effect display (built-in effect) 

16 

Priority 2: 

dynamic effect 

0-9 

No function 

10-255 

12 values for an effect, 20 effects 

17 

Backlight color R 

0-255 

0~255 control (15,16) channel backlight 

18 

Backlight color G 

0-255 

0~255 control (15,16) channel backlight 

19 

Backlight color B 

0-255 

0~255 control (15,16) channel backlight 

20 

Backlight color W 

0-255 

0~255 control (15,16) channel backlight 

21 

Effect direction 

adjustment 

0-127 

Positive direction of dynamic pattern 

128-255 

Dynamic pattern reverse direction 

22 

  Effect speed 

0-255 

Dynamic from fast to slow 

23 

Priority 1: 
Macro function 

0-9 

No function 

10-99 

Auto 1 

100-199 

Auto 2 

200-255 

Light body sound control 

24 

Reset 

0-239 

No function 

240-250 

The lamp body is reset, valid for 3s. 

251-255 

No function 

 

Routine maintenance 

1.Cleaning and maintenance 

The equipment requires daily cleaning and maintenance. The service life of the equipment 
largely depends on the operating environment and daily cleaning and maintenance. The 
power must be disconnected before opening any cover. 

Summary of Contents for IM-MH3715

Page 1: ...1 1 37x15W BEAM WASH ZOOM MOVING HEAD IM MH3715 USER MANUAL Please read the instructions carefully before using the product and keep it properly ...

Page 2: ... decrease the address number After the address is selected Press Enter to save and exit There are 24 channel and 48 channel mode options for channels 2 Run Mode Set the working mode of the moving head light This option is used to set the working mode of the moving head light Press the Enter key to enter the setting page press the UP key or the DOWN key to select the working mode and the working mo...

Page 3: ...light on setting 5 Manual Set Manual mode setting This option is to set the scene parameters of the moving head light press the Enter key to enter the save and online operation can be carried out provided that the moving head light s operating mode Run Mode must be set to manual that is the manual mode is valid The next startup can restore the previous startup state PAN X axis position PANMICO X a...

Page 4: ... X axis 0 255 0 540 degrees 2 X axis fine adjustment 0 255 16 bit adjustable 3 Y axis 0 255 0 270 degrees 4 Y axis fine adjustment 0 255 16 bit adjustable 5 XY speed 0 255 XY axis horizontal vertical speed from fast to slow 6 focusing 0 255 Focus light from near to far 7 Total dimming 0 255 Linear dimming from dark to bright 8 Strobe 0 9 No function 10 154 Synchronous strobe speed from slow to fas...

Page 5: ...n color effects 1 20 29 Built in color effects 2 30 39 Built in color effects 3 40 49 Built in color effects 4 50 59 Built in color effects 5 60 69 Built in color effects 6 70 79 Built in color effects 7 80 89 Built in color effects 8 90 99 Built in color effects 9 100 109 Built in color effects 10 110 119 Built in color effects 11 120 129 Built in color effects 12 130 139 Built in color effects 1...

Page 6: ... pattern effect display built in effect 40 Priority 2 dynamic effect 0 9 No function 10 255 12 values for an effect 20 effects 41 Backlight color R 0 255 0 255 control 39 40 channel backlight 42 Backlight color G 0 255 0 255 control 39 40 channel backlight 43 Backlight color B 0 255 0 255 control 39 40 channel backlight 44 Backlight color W 0 255 0 255 control 39 40 channel backlight 45 Speed dire...

Page 7: ...ects 1 20 29 Built in color effects 2 30 39 Built in color effects 3 40 49 Built in color effects 4 50 59 Built in color effects 5 60 69 Built in color effects 6 70 79 Built in color effects 7 80 89 Built in color effects 8 90 99 Built in color effects 9 100 109 Built in color effects 10 110 119 Built in color effects 11 120 129 Built in color effects 12 130 139 Built in color effects 13 140 149 B...

Page 8: ... effect 16 Priority 2 dynamic effect 0 9 No function 10 255 12 values for an effect 20 effects 17 Backlight color R 0 255 0 255 control 15 16 channel backlight 18 Backlight color G 0 255 0 255 control 15 16 channel backlight 19 Backlight color B 0 255 0 255 control 15 16 channel backlight 20 Backlight color W 0 255 0 255 control 15 16 channel backlight 21 Effect direction adjustment 0 127 Positive...

Page 9: ...cing Make sure there are no flammable materials close to the unit while operating as it is fire hazard Use safety cable when fixes this unit DO NOT handle the unit by taking its head only but always by taking its base Maximum ambient temperature is Ta 40 DO NOT operate it where the temperature is higher than this Unit surface temperature may reach up to 85 DO NOT touch the housing bare hand during...

Page 10: ...y cable that can hold 12 times of the weight of the unit when installing the fixture The equipment must be fixed by professionals And it must be fixed at a place where is out of the touch of people and has no one pass by or under it All information is subject to change without prior notice More info please visit www imrelax com Email kevin imrelax com ...

Reviews: