3)  Double click the steam-ready butt on“ 

 ” to generate conti nuous steam to clean the 

jewelry. Press the steam-ready butt on“ 

 ” to stop steam.

NOTE: The steam heati ng takes approximately 3.5 minutes aft er pressing the steam 

on/off  butt on. The steam-ready butt on light will turn RED when the steam is ready to 

be dispersed. 

4)  Using the tweezers, place the jewelry in the stainless steel basket. Double click the 

steam-ready butt on to turn on steam. Allow to steam for approximately 2 seconds, turn 

off  steam by pressing the steam-ready butt on once. Using your tweezers, rotate or turn 

jewelry in basket, conti nue steaming for another 2 seconds. If more steam cleaning is 

required repeat the process as necessary.

5)  You may also hold the jewelry by using the tweezers during steam cleaning. Hold jew-

elry approximately one inch beneath the steam nozzle. Using your tweezers, rotate or 

turn jewelry during steam process. Allow to steam for approximately 2 seconds. Repeat 

process as necessary.

 

CAUTION: Jewelry will get hot during steam cleaning. Handle with care 

and allow to cool.

NOTE: When steamer loses steam pressure, the steamer will automati cally stop steaming and the 

steam-ready light will turn off. In approximately 5 seconds, the steam-ready light will turn back 

on, indicati ng that steam is available. We recommend that you wait an additi onal 60 seconds to 

allow the steam pressure to build up. You are ready to steam clean again. If the steam-ready light 

illuminates but no steam comes out when double clicking the steam-ready butt on that indicates 

the water tank is empty. Press Power on/off  butt on to turn off  and unplug from the outlet. Allow 30 

minutes for the steamer to cool before refi lling the water tank.

 CAUTION: Never attempt to unscrew the water tank cap and refill the 

water tank while it is sti ll hot and under pressure.

 WARNING: The steam nozzle, water tank cap, and the surrounding areas 

will become hot aft er using the steam functi on. Do not touch.

Summary of Contents for DAZZLE

Page 1: ...DAZZLE 3 in 1JewelryCleanerandSanitizer SJC 1601 INSTRUCTION MANUAL ...

Page 2: ...ot be cleaned in an ultrasonic cleaner steam cleaner and or exposed to UV light the guidelines are not represented as being complete and are not meant to be used as your final determination as to whether or not the jewelry in question is suitable for being cleaned by the jewelry cleaner Before cleaning any piece of jewelry or gemstone you should consult with a professional to correctly identify th...

Page 3: ...though it is leaking Never touch the boiling water or you may get burned Never operate the jewelry cleaner without sufficient water in the ultrasonic reservoir and water tank Never attempt to unscrew the water tank cap while it is still hot and under pressure If the steamer runs out of steam during use turn it off and unplug it Allow 30 minutes for the steamer to cool before refilling the water tank...

Page 4: ...te Not Recommended Not Recommended Yes Jade Moderate Yes Yes Yes Lapis Lazuli Moderate Not Recommended Not Recommended Yes Malachite Fragile Not Recommended Not Recommended Yes Marcasite Moderate Not Recommended Not Recommended Not Recommended Onyx Moderate Yes Yes Yes Opal Moderate Not Recommended Not Recommended Yes Pearl Fragile Not Recommended Not Recommended Yes Peridot Moderate Not Recommend...

Page 5: ...utinely treated to improve the appearance of color and clarity These treatments can be negatively affected by heat solvents steam and ultrasonic cleaners Knowing whether your gem has been treated is the first step to knowing how to care for it Durability of Gemstones is based on the Mohs Scale Mohs Scale 1 10 1 weakest 10 strongest Mohs Scale Durability Scale 1 4 Fragile 5 7 Moderate 8 10 Strong G...

Page 6: ... on off button D Steam on off button E Steam ready button F Ultrasonic button G UV button H Steam Nozzle I Base plate J Side door K Hanger L Ultrasonic reservoir M Measuring cup N Stainless steel basket O Tweezers P Funnel A L B C D E H J K M N O G F P I ...

Page 7: ...n the electrical cord yet 2 Remove the upper cover and take out the measuring cup and funnel from the ultrasonic reservoir NOTE Leave the upper cover off during use 3 Open the side door and take out the stainless steel basket and tweezers from the UV chamber Then close the side door ...

Page 8: ...the water tank is overfilled it will produce a hazardous spatter of wet stream Never touch the boiling water or you may get burned NOTE The maximum water tank capacity is 350ml 12 fl oz NOTE The jewelry cleaner does not require distilled water Residents in areas with hard water should use distilled water for better performance Fill water tank with water only Do not add any type of chemicals or clea...

Page 9: ...anel to turn on 3 Ultrasonic will shut off after 5 minutes automatically with beep indicator You can shut off the ultrasonic function if 5 minutes is not required by pressing the ultrasonic button a second time 4 Items that are very dirty should be cleaned first in the ultrasonic reservoir and then with the steamer 5 While waiting for the ultrasonic cleaning press the steam on off button for heati...

Page 10: ... jewelry during steam process Allow to steam for approximately 2 seconds Repeat process as necessary CAUTION Jewelry will get hot during steam cleaning Handle with care and allow to cool NOTE When steamer loses steam pressure the steamer will automatically stop steaming and the steam ready light will turn off In approximately 5 seconds the steam ready light will turn back on indicating that steam ...

Page 11: ...endedthatyourotateyouritemsolighthitsallsidesoftheitem NOTE In order to kill 99 9 of all bacteria such as E coli Staphylococcus and Salmonella 30 minutes is required for full sanitization NOTE The UV Light will shut off automatically if you open the side door during the UV cycle to avoid UV leakage Once the side door is closed the UV light will turn back on to continue sanitizing for the remaining...

Page 12: ...team cleaner while still hot and under pressure 3 Empty the water tank and the ultrasonic reservoir when storing the unit for a prolonged period 4 Wipe the jewelry cleaner and accessories with a soft cloth when if necessary CUSTOMER SUPPORT For problems with your Improvements Dazzle 3 in 1 Jewelry Cleaner and Sanitizer please refer to Troubleshooting guide Additional inquiries should be directed t...

Page 13: ...dy button Calcium and mineral deposits can build up and impact performance ofyoursteamer usedistilledwaterifnecessary UV light not working Ensure control panel lights are on Make sure to press the UV light button Ensure the UV Side door is completely closed Ensure UV light hasn t come lose during handling and shipping Open UV side door remove protective cover by pulling outwards firmly Ensure UV l...

Page 14: ...that is covered by this warranty As a matter of warranty policy the manufacturer will not refund the purchase price A repaired or replacement product will be covered by this warranty for the balance of the initial one year warranty period To contact Customer Service Write Anvid Products Inc 1401 1499 Greenville Rd Livermore CA 94550 E mail customerservice anvidproducts com Call 1 888 5SIENNA 1 888...

Page 15: ...QUENTIAL DAMAGES LOSSES OR EXPENSES YOU MAY INCUR IN CONNECTION WITH YOUR PURCHASE PRIOR TO USE OF THE PRODUCT OR FOR ANY BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED WHATSOEVER Some states do not allow exclusion or limitation of special incidental or consequential damages so the above limitation may not apply to you This limited warranty gives you specific legal rights and you may also...

Page 16: ...16 ...

Reviews: