COLD AIR
–
FPA KITCHEN 5.0
Section 3
–
Protection Devices
3.4 Connection to the water supply
For the water supply, the
FPA-KITCHEN
Air Cooler is
equipped with a 3/8” water inlet
connection, positioned in the lower part of the Machine.
The Customer must provide a water shut-off valve at the Machine inlet.
Together with
FPA-KITCHEN
Air Cooler
IMPRESIND SRL
supplies a special water filtration
kit, to be installed before the water inlet valve.
For a correct connection, please read the specific information sheet.
The water pipe must guarantee a minimum capacity of 5 -10 Litre/Minute, at a pressure of
1.5 - 3 bars (maximum pressure allowed: 6 bars).
It is advisable to have the water pipe installed inside the building, in order to protect it against
freezing during winter. Provide for the possibility of emptying the water pipe; on contrary,
provide for an adequate insulation.
ATTENTION
DO NOT use excessive force
on the water inlet connection
when connecting to the water
supply system.