Summary of Contents for Cold AIR FPA KITCHEN 5.0

Page 1: ...STP101 131 GB ed 01 20 ADIABATIC EVAPORATIVE AIR COOLER MODEL FPA KITCHEN 5 0 Installation Operation and Maintenance Instruction Manual ...

Page 2: ...STP101 131 GB ed 01 20 2 COLD AIR FPA KITCHEN 5 0 ...

Page 3: ...on to the water supply 16 4 1 Protection devices 18 4 2 Work clothing 18 4 3 Residual risks 18 4 4 Emergency situations 18 SECTION 5 USE OF FPA KITCHEN EVAPORATIVE COOLER 19 5 1 Control panel 19 5 2 Description of controls and signals 20 5 2 1 Control panel description 20 5 2 2 Signals description 21 5 4 Operation 22 5 5 Change of the circulating water 22 5 6 Shut down 22 5 6 1 Shutdown automatic ...

Page 4: ...hive system in any mechanical magnetic optical chemical or other form or means without written authorization by IMPRESIND SRL This manual must be kept and conserved until the final dismantling of the machine in case of transfer it must be handed over to the new owner If a fault occurs causing machine shutdown IMPRESIND SRL is not liable in any way for any damage caused by the shutdown and in no wa...

Page 5: ...ollowing European Community Directives 2006 42 EEC Machinery Directive 2014 35 EEC Low Voltage Directive 2014 30 EEC Electromagnetic Compatibility Directive 2009 125 EEC Energy Related Products ERP Directive IMPRESIND SRL declines all responsibility for any damages which may be directly or indirectly caused to exposed persons or property due to improper use or use of the machine for different purp...

Page 6: ... the exhaust air extraction system and by the frequent opening of the doors for carrying out the activity An excellent solution is represented by the evaporative cooler system that cools the air with a natural principle the air passes through special wet filters gives way part of its heat during the process of evaporation of water and lowers its temperature The absence of refrigeration equipment r...

Page 7: ...l premises and warehouses sport venues in general such as gymnasiums professional kitchens The machine must NOT be used for a different use than its designed use for any reason whatsoever or used in a different way than stated in this manual DO NOT install the machine in external areas the machine must be installed inside the area to be treated except by specific approval of the manufacturer When ...

Page 8: ... other purposes than those stated at paragraph 1 4 of this instruction manual Any machine modification is forbidden and determines the loss of the product warranty In case of product modification IMPRESIND SRL declines all responsibility for the product IT IS ABSOLUTELY FORBIDDEN TO USE WATER TO PUT OUT FIRES IT IS ABSOLUTELY FORBIDDEN TO MAKE MODIFICATIONS TO THE ELECTRICAL BOARD IT IS ABSOLUTELY...

Page 9: ...by the shipping agent then send a copy by fax or email to IMPRESIND SRL In order to avoid any damage to the machine pay great attention when unloading from the transportation mean handling and positioning Avoid contact with elements that may damage the machine Make sure that the capacity of the lifting equipment is adequate for the weight of the machine Lifting must be carried out by qualified per...

Page 10: ...s transportation packaging base with any protection guards mounted so that the lower part is raised from the floor and is not damaged until the machine is installed on the provided devices 2 5 Storage During transportation and storage make sure that the ambient temperature is between 10 C and 50 C If the machine has to be stored make sure that the relative humidity in the warehouse is between 5 an...

Page 11: ...ioning and installation of the Machine must be carried out by qualified personnel and by observing the laws in force in the country of destination 3 2 Positioning and installation of FPA KITCHEN Air Cooler COLD AIR Air Coolers Mod FPA KITCHEN are machineries designed for wall or window installation These machines must be installed in the internal side of the premise Thanks to their small size and ...

Page 12: ...as parts of the machine frame to allow the fixing anchoring of the Machine It is very important to leave the necessary free space around and below the Machine to allow an easy connection of various utilities e g power supply water supply and drainage The following pictures shows some examples of possible installation It is strictly forbidden to put or hang weights on the Machine and to use it as a...

Page 13: ...esigned and built according to the regulations in force in the country where the Machine is installed It s absolutely necessary to respect the phase polarity and the number order of wires and terminals Carry out the wire connections as per the wiring diagram attached to this manual also refer to the copy of the wiring diagram placed into the electrical panel of the Machine Connection to the power ...

Page 14: ...STP101 131 GB ed 01 20 14 COLD AIR FPA KITCHEN 5 0 Section 3 Protection Devices WIRING DIAGRAM FOR CONNECTIONS Legenda ...

Page 15: ...pplied with its display control panel completely pre wired and tested The installer has only to connect the Machine to the power supply by removing in sequence as first the base frontal panel picture below and then the cover of the electrical box For power supply connection use the highlighted terminals ...

Page 16: ...ter filtration kit to be installed before the water inlet valve For a correct connection please read the specific information sheet The water pipe must guarantee a minimum capacity of 5 10 Litre Minute at a pressure of 1 5 3 bars maximum pressure allowed 6 bars It is advisable to have the water pipe installed inside the building in order to protect it against freezing during winter Provide for the...

Page 17: ...chine The water discharge hose can exit the Machine from the bottom or from the back see the picture below Connect the hose to the water discharge system according to the hygiene regulations in force in the country where the Machine is installed ATTENTION When connecting the water discharge hose to the discharge valve inside the Machine make sure the connection is tight and sealed To avoid leakage...

Page 18: ...prescriptions regarding work clothing are not necessary Maintenance personnel must use suitable work clothing and wear individual protection devices 4 3 Residual risks 4 4 Emergency situations Pay attention to fan movement Do not introduce arms or limbs Mechanical danger In case of emergency stop the machine immediately and cut off the electrical supply by switching off the omnipolar circuit break...

Page 19: ...display that allows the various control operations ON OFF COOLING VENTILATION MODE FAN SPEEDS The Control Panel is equipped with a microcontroller that allows the possibility to set all the functions and parameters necessary to ensure a proper and good operation of the Machine pre cleaning periodical panel cleaning end cycle final washing all these functions are needful for good running of the Mac...

Page 20: ... mode In case the keyboard is freezed by pressing ON OFF for about 3 seconds the keyboard is reset FAN When running it allows to display the fan speed and eventually to modify it by pressing UP or DOWN buttons By pressing it a second time the modification is confirmed UP To select Cooling or Ventilation mode when the Machine is OFF To increase the fan speed when the Machine is running By pressing ...

Page 21: ...s in the central part of the display OFF The Machine is powered but it is in stand by mode waiting for the start command COOL the Cooling Mode is selected and the machine is running in cooling mode FAN the Ventilation Mode is selected and the Machine is running in ventilation mode F1 F2 information related to the selected fan speed Bar graph that indicates the actual fan speed This control device ...

Page 22: ...Machine in Stand by and then select the new running mode WARNING Before changing from Colling mode to Ventilation mode make sure that the automatic processes of washing and final water discharge are finished ADDITIONAL INFORMATION ABOUT COOLING MODE When the fan is running at the minimum speed and the control panel does not accept a new input selection this is not a failure but it is normal set of...

Page 23: ... an adequate cooling the air introduced by the machine should be able to get out For more detailed information refer to chapter 5 7 Air Changes Don t start the Machine if it is not possible to evacuate the cold air introduced The cooling efficiency is not only related to the Machine efficiency but it depends also on different additional variables that are independent from the machine itself like t...

Page 24: ...h humidity days even if it reaches an efficient cooling level In areas with high Relative Humidity the evaporative cooling system must be oversized in order to guarantee more air changes or in other words it must have a higher capacity to compensate the smaller temperature difference obtained In these areas the maximum cooling effect will be reached by making sure that there are more air evacuatio...

Page 25: ...n anomalies The water pump does not provide a correct wetting of the evaporative panels This could be caused by a residual dirt in the water circuit Check the water circuit and clean remove any obstruction or dirt accumulation Not homogeneous wetting of the evaporative panel This could be caused by water with high hardness level which caused the clog some holes of the water wetting system Floating...

Page 26: ...STP101 131 GB ed 01 20 26 COLD AIR FPA KITCHEN 5 0 Section 5 Operations 5 11 Safety signs onboard the Machine ELECTRICAL HAZARD Risk of electric shock due to components connected to power line ...

Page 27: ...e internal bottom of the Machine Use a mild detergent don t use any solvent because it may react with the plastic materials 8 Put back in place the front panel make sure it is properly installed and check the bolts tightening 6 2 Pre season maintenance In order to keep and preserve the Machine in perfect working conditions it is recommended a maintenance intervention before the Machine is started ...

Page 28: ...name of the technician It is reminded solvents are not allowed in cleaning operations to avoid any damage to the electrical cables The maintenance personnel must be professionally qualified Before carrying out any maintenance operation read carefully this section of the manual For any need contact the Technical Assistance Service at IMPRESIND SRL IMPRESIND SRL is not responsible for any damage or ...

Page 29: ...o any movement mechanism It is forbidden to Leave any flammable material near to the electrical panels Work on the electrical equipment without isolating the equipment from the power supply lines Work on any part of the Machine before the plant has come to a stop Operate the Machine with the safety systems deactivated or removed Deactivate or evade the alarm signals Ignore the warning signals and ...

Page 30: ...m the side as shown below FRONT ACCESS To open the front panel and access the evaporative panel remove the lower front panel 1 disconnect the wires connections among the electric enclosure and the fan and command display remove the upper front panel 2 caring about the fan and the control display to avoid to damage them the evaporation panel is now accessible and it can they be easily removed SIDE ...

Page 31: ...p and extract the evaporation panels once per time Start to remove the panel at the opposite side of the pump and then slide the second panel and remove it too 6 5 Technical assistance request For any request of technical assistance intervention contact the installer or eventually contact the Technical Assistance Service of IMPRESIND SRL Production Headquarters Via Primo Maggio 24 20064 Gorgonzola...

Page 32: ...ant all materials that makes up the plant must be collected and sent to the appropriate collection and disposal centres better by contacting companies specialized in equipment disposal Disassembly of the Machine must be carried out by specialized personnel equipped with suitable equipment and personal individual protection devices Do not smoke and do not use open flames ...

Page 33: ...STP101 131 GB ed 01 20 33 COLD AIR FPA KITCHEN 5 0 Section 8 Technical Drawings ...

Page 34: ...1 131 GB ed 01 20 34 COLD AIR FPA KITCHEN 5 0 Section 8 Technical Drawings IMPRESIND SRL Via Primo Maggio 24 20064 Gorgonzola Milan ITALY 39 02 9574 1932 39 02 9574 0637 info impresind com www impresind com ...