INTRODUCTION 

Congratulations on your purchase of the IMPECCA™ Mechanical Controlled Compact Window Air Conditioner.  Before 
using this product, it is recommended that you familiarize yourself with the features, functions, and operating 
procedures described in this manual.   Inside you will find many helpful hints on how to use and maintain your air 
conditioner properly.  Just a little preventive care on your part can save you a great deal of time and money over the 
lifespan of your air conditioner. You will find many answers to common problems in the chart of troubleshooting tips. If 
you review our chart of Troubleshooting Tips first, you may not need to call for service at all. 

Features at a Glance 

Whisper Quiet Operation

2 cooling speeds /  2 fan speeds

Eco-Friendly Refrigerant

PRECAUTIONS 

To prevent injury and/or property damage, please familiarize yourself with the following instructions and safety 
precaution. Failure to comply with the instructions and cautions mentioned in this manual may cause harm or 
damage.  The seriousness is classified by the following indications: 

This symbol indicates the possibility of serious injury or death.

 

This symbol indicates the possibility of injury and/or damage to property.

 

Never do this. 

Always do this. 

IMPORTANT: 

Always contact an authorized service technician for repair or maintenance of this unit.

This air conditioner is not intended for use by young children or infirm persons without supervision.

Young children should be advised not to operate the air conditioner.

If the power cord is to be replaced, replacement work should only be performed by certified or
authorized technicians.

All electrical work must be performed in accordance with the national wiring standards and should
only be performed by authorized personnel.

Due to slight modifications in production, the instructions, features, and/or descriptions found in this manual might be 
slightly different from your product. 

Summary of Contents for IWA-05KM15

Page 1: ...Mechanical Controlled Mini Window Air Conditioner User s Guide Acondicionador de Aire de Ventana Compacto y Controlado Electronico Manual del Usuario Model IWA 05KM15 5000 Btu Model IWA 06KM15 6000 Bt...

Page 2: ...tion of Power Cord Current Device 11 Air Conditioner Features and Operation Instructions 11 Care and Cleaning 16 Additional Things You Should Know 17 Troubleshooting Tips 19 ESTE MANUAL ES TAMBI N DIS...

Page 3: ...th the following instructions and safety precaution Failure to comply with the instructions and cautions mentioned in this manual may cause harm or damage The seriousness is classified by the followin...

Page 4: ...de 3 Window Installation Kit Not shown 2 1 1 Mechanical Controlled Mini Window Air Conditioner User s Guide Acondicionador de Aire de Ventana Compacto y Controlado Electronico Manual del Usuario Model...

Page 5: ...correct grounding may cause electric shock Doing so may cause failure of the unit and or electric shock Incorrect installation may cause fire and or electric shock Unplug the unit if you notice strang...

Page 6: ...o may result in damage as water may seep in or electrical overload may occur Failure to turn off unit first may result in shock Doing so will help preserve the lifespan of this unit Ensure that the in...

Page 7: ...ed on the side of the cabinet and behind the grille Be sure the air conditioner is properly grounded To minimize shock and fire hazards proper grounding is important The power cord is equipped with a...

Page 8: ...and these installation instructions for future reference The carton is the best way to store the unit during winter or when the unit will not be used for an extended period of time It may also be nec...

Page 9: ...stalled the flange for securing the panel in place to the windowsill will be facing into the room FIG 3C 3 Align the hole in the top rail with those in the top of the unit as shown in Figure B 4 Secur...

Page 10: ...s been installed on the side of the cabinet make sure it sits securely inside the frame channel by making slight adjustments Slide the top and bottom ends of the frame into the top and bottom rails of...

Page 11: ...r slots are not caulked or painted shut Accumulated rainwater or condensation must be allowed to drain out Sash Storm window frame or other obstruction 1 Min 38mm Board thickness as required for prope...

Page 12: ...e repaired It MUST be replaced by one obtained from the product manufacturer AIR CONDITIONER FEATURES AND OPERATION INSTRUCTIONS WARNING To reduce the risk of fire electric shock or injury to persons...

Page 13: ...an or Hi fan Note When in fan mode the compressor will not run Thermostat The thermostat is used to set the desired room temperature when the unit is being operated in HI COOL or LO COOL mode To set t...

Page 14: ...shing you may vacuum the filter clean Note Never use hot water over 40 C 104 F to clean the air filter Never attempt to operate the unit without the air filter Cabinet Cleaning Be sure to unplug the a...

Page 15: ...you may hear the sound of rushing air being moved by the fan Vibration Unit may vibrate and make noise because of poor wall or window construction or incorrect installation Pinging or Switching Dropl...

Page 16: ...tart when in the COOL mode Air conditioner cooling but room is too warm ice forming on cooling coil behind decorative front panel 1 Outdoor temperature below 18 C 64 F To defrost the coil set to FAN O...

Page 17: ...y to the outside to allow water drainage Refer to installation instruction or check with installer Water dripping OUTSIDE when unit is cooling 1 Unit removing large quantity of moisture from humid roo...