CARE AND CLEANING 

CAUTION 

Clean your air conditioner occasionally to keep it looking new.  

Be sure to unplug the unit before 

cleaning to prevent shock or fire hazards. 

Air Filter Cleaning  

The air filter should be checked at least once a month to see if 
cleaning is necessary. Trapped particles in the filter can build 
up and cause an accumulation of frost on the cooling coils.  

Remove the filter by sliding it out from the right hand
side to the Vent Closed position (where applicable).

Wash the filter using liquid dishwashing detergent and
warm water.

Rinse filter thoroughly.

Gently shake excess water from the filter. Be sure the
filter is thoroughly dry before replacing.

Note:

  Instead of washing, you may vacuum the filter clean. 

Note:  

Never use hot water over 40° C (104° F) to clean the air 

filter. Never attempt to operate the unit without the air filter. 

Cabinet Cleaning 

Be sure to unplug the air conditioner to prevent shock or
fire hazard. The cabinet and front may be dusted with an
oil-free cloth or washed with a cloth dampened in a
solution of warm water and mild liquid dishwashing
detergent. Rinse thoroughly and wipe dry.

Never use harsh cleaners, wax or polish on the cabinet
front.

Be sure to wring excess water from the cloth before wiping
around the controls. Excess water in or around the controls
may cause damage to the air conditioner.

Plug in air conditioner.

Winter Storage 

If you plan to store the air conditioner during the winter, 
remove it carefully from the window according to the 
installation instructions. Cover it with plastic or return it 
to the original carton.

 

Summary of Contents for IWA-05KM15

Page 1: ...Mechanical Controlled Mini Window Air Conditioner User s Guide Acondicionador de Aire de Ventana Compacto y Controlado Electronico Manual del Usuario Model IWA 05KM15 5000 Btu Model IWA 06KM15 6000 Bt...

Page 2: ...tion of Power Cord Current Device 11 Air Conditioner Features and Operation Instructions 11 Care and Cleaning 16 Additional Things You Should Know 17 Troubleshooting Tips 19 ESTE MANUAL ES TAMBI N DIS...

Page 3: ...th the following instructions and safety precaution Failure to comply with the instructions and cautions mentioned in this manual may cause harm or damage The seriousness is classified by the followin...

Page 4: ...de 3 Window Installation Kit Not shown 2 1 1 Mechanical Controlled Mini Window Air Conditioner User s Guide Acondicionador de Aire de Ventana Compacto y Controlado Electronico Manual del Usuario Model...

Page 5: ...correct grounding may cause electric shock Doing so may cause failure of the unit and or electric shock Incorrect installation may cause fire and or electric shock Unplug the unit if you notice strang...

Page 6: ...o may result in damage as water may seep in or electrical overload may occur Failure to turn off unit first may result in shock Doing so will help preserve the lifespan of this unit Ensure that the in...

Page 7: ...ed on the side of the cabinet and behind the grille Be sure the air conditioner is properly grounded To minimize shock and fire hazards proper grounding is important The power cord is equipped with a...

Page 8: ...and these installation instructions for future reference The carton is the best way to store the unit during winter or when the unit will not be used for an extended period of time It may also be nec...

Page 9: ...stalled the flange for securing the panel in place to the windowsill will be facing into the room FIG 3C 3 Align the hole in the top rail with those in the top of the unit as shown in Figure B 4 Secur...

Page 10: ...s been installed on the side of the cabinet make sure it sits securely inside the frame channel by making slight adjustments Slide the top and bottom ends of the frame into the top and bottom rails of...

Page 11: ...r slots are not caulked or painted shut Accumulated rainwater or condensation must be allowed to drain out Sash Storm window frame or other obstruction 1 Min 38mm Board thickness as required for prope...

Page 12: ...e repaired It MUST be replaced by one obtained from the product manufacturer AIR CONDITIONER FEATURES AND OPERATION INSTRUCTIONS WARNING To reduce the risk of fire electric shock or injury to persons...

Page 13: ...an or Hi fan Note When in fan mode the compressor will not run Thermostat The thermostat is used to set the desired room temperature when the unit is being operated in HI COOL or LO COOL mode To set t...

Page 14: ...shing you may vacuum the filter clean Note Never use hot water over 40 C 104 F to clean the air filter Never attempt to operate the unit without the air filter Cabinet Cleaning Be sure to unplug the a...

Page 15: ...you may hear the sound of rushing air being moved by the fan Vibration Unit may vibrate and make noise because of poor wall or window construction or incorrect installation Pinging or Switching Dropl...

Page 16: ...tart when in the COOL mode Air conditioner cooling but room is too warm ice forming on cooling coil behind decorative front panel 1 Outdoor temperature below 18 C 64 F To defrost the coil set to FAN O...

Page 17: ...y to the outside to allow water drainage Refer to installation instruction or check with installer Water dripping OUTSIDE when unit is cooling 1 Unit removing large quantity of moisture from humid roo...

Reviews: