17
Use the following guidelines to understand and troubleshoot common error codes.
E1
: Room temperature sensor error.
E2
: Evaporator temperature sensor error
E3
: Condenser temperature sensor error
E4
: Display panel communication error
• For all of the above errors, unplug the unit and plug it back in.
P1
: Bottom condensation tray is full
• Connect the drain hose and drain the collected water away.
• Note that frequent draining may be required, especially in humid climates
and during seasonal weather changes.
• If protection repeats after draining, call for service.
BASIC UNIT ERROR CODES:
CAUTION
ADDITIONAL REMOTE CONTROLLER INFORMATION
• Do not mix old and new batteries or batteries of a different type (e.g. alkaline and zinc).
• Do not leave the batteries in the remote controller if it is not going to be used for 2–3 months.
• Dispose of the old batteries in special battery disposal collection containers at sales sites or wherever local law
states batteries may be disposed of.
REMOTE CONTROLLER SPECIFICATIONS
Rated Voltage
3.0V (Dry batteries AAA x2)
Lowest Voltage of
CPU Emitting Signal
2.0 V
Signal Receiving Range
26 feet / 8m
Environment
~41° F to 140° F (5°C to 60°C)
NOTE:
All drawings in this manual are
for illustrative purposes only. The actual
shape and functions of your unit and re-
mote controller may vary slightly.