8

FRONT PANEL OVERVIEW:

The following diagram and legend shows the functions of the front operating panel . Some functions are 

only available on select models .
When you push the button to change operation modes, the unit will make a beep sound to indicate that it 

is changing modes .

1) Pump Button

Press to activate continuous pump drainage mode.

2) Filter Button

The check filter indicator is a feature to remind you clean 
the air filter for more efficient operation. The filter light will 
illuminate after 250 hours of operation. Toreset after cleaning 
the filter, press the filter button and the light will go off.

3) Fan Speed Button

Control fan speed. Press to select either high or normal fan 
speeds. Set the fan speed to high for maximum moisture 
removal. When the humidity is reduced or quiet operation is 
preferred, set the fan speed to normal.

4) Power Button

Turns the unit on and off.

5/7) Up (+) & Down (–) Buttons 

The relative humidity (RH) can be set within a range of 35% 
to 85% in 5% increments. For drier air, press the pad and set a 
lower percentage value (%). For damper air, press the pad and 
set a higher percentage value (%).

6) Timer Button

Activate the unit for a set period of time, increased and 
decreased using the + and – buttons

DISPLAY: 

Shows the set % humidity level from 35% to 85% or auto start/stop time (0~24) while setting, then shows the ac-

tual (5% accuracy) room % humidity level in a range of 30% RH (Relative Humidity) to 90%RH (Relative Humidity) .

ERROR CODES AND PROTECTION CODES:

AS) Humidity sensor error—Unplug the unit and plug it back in . If error repeats, call for service .
ES) Temperature sensor error—Unplug the unit and plug it back in . If error repeats, call for service .
P2) Reservoir is full or reservoir is not seated correctly—Empty the reservoir and replace it in the right position .
EC) Unit malfuction—Please make sure whether the enviroment temperature is suitable for the stated temperature in the 

manual or not . If not, please operate the unit under the stated temperature . If the enviroment temperature is suitable for the 

stated temperature, please call for service .
E3) Unit malfuction—unplug the unit and plug it back in . If the error persists, contact technical support immediately .
Eb) The condensor collection bucket is in the wrong position . Remove the bucket and reposition it correctly .

Summary of Contents for IDM-52SP

Page 1: ...1 Impecca Dehumidifier User Manual Models IDM 52SP IDM 72SP ...

Page 2: ... where electronic waste can be disposed of at least free of charge to the user B When buying a new product the retailer will take back the old product at least free of charge C The manufacturer will take back the old appliance for disposal at least free of charge to the user D As old products contain valuable resources they can be sold to scrap metal dealers Wild disposal of waste in forests and l...

Page 3: ...this manual may cause harm or damage The seriousness is classified by the following indications IMPORTANT Always contact an authorized service technician for repair or maintenance of this unit This dehumidifier is not intended for use by young children or elderly persons without supervision Young children should be advised not to operate the dehumidifier If the power cord is to be replaced replace...

Page 4: ...r death WARNING FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors liquids in the vicinity of this or any other appliance Avoid fire hazard or electric shock Do not use an extension cord or an adapter plug Do not remove any prong from the power cord WARNING ELECTRICAL INFORMATION Be sure your electrical wiring is adequate for the model you have chosen This information can be fo...

Page 5: ...re water may splash onto the unit Place the unit on a level sturdy section of the floor Lack of ventilation can cause overheating and fire Water may enter the unit and degrade the insulation It may cause an electric shock or fire If the unit falls over it may cause water to spill and damage belongings or cause electrical shock or fire Do not cover the intake or exhaust ope nings with cloths or tow...

Page 6: ...ater reservoir 6 Handle both sides 1 Drain hose outlet 2 Rolling casters 3 Power cord and plug 4 Band used only when storing unit 5 1 2 3 4 6 1 2 3 NOTE All drawings in this manual are for illustrative purposes only The actual shape of the unit you purchased may be slightly different but the operations and functions are the same ...

Page 7: ...vent moisture damage anywhere books or valuables are stored Use the dehumidifier in a basement to help prevent moisture damage The dehumidifier must be operated in an enclosed area to be most effective Close all doors windows and other outside openings to the room WHEN USING THE UNIT When first using the dehumidifier operate the unit continuously 24 hours This unit is designed to operate with a wo...

Page 8: ... do not touch any parts inside of the unit Doing so may damage the product Be sure to push the reservoir gently all the way into the unit Banging the reservoir against anything or failing to push it in securely may cause the unit to stop operating If water spills or is found within the unit upon removing the reservoir you must dry the unit carefully IMPORTANT When removing the reservoir ensure the...

Page 9: ...s the pump button on the unit to activate the pumping function When the reservoir is full the pump will operate for 3 5 minutes and empty the reservoir Note that the pump may produce a loud noise this is normal Make sure the hose is secure so there are no leaks Direct the hose toward the drain making sure that there are no kinks that will stop the water flow Place the end of the hose into the drai...

Page 10: ...value For damper air press the pad and set a higher percentage value 6 Timer Button Activate the unit for a set period of time increased and decreased using the and buttons DISPLAY Shows the set humidity level from 35 to 85 or auto start stop time 0 24 while setting then shows the ac tual 5 accuracy room humidity level in a range of 30 RH Relative Humidity to 90 RH Relative Humidity ERROR CODES AN...

Page 11: ...the unit will restart with the previous function settings automatically when power returns TIMER FUNCTION The timer indicator lights are for two separate functions one to automatically turn the unit on and another to automatically shut it off Both programs can be set at the same time Setting the unit to automatically turn off Push the timer button once if dehumidifier is running or twice if dehumi...

Page 12: ...shwasher to clean the reservoir After cleaning the reservoir must be in place and securely seated for the dehumidifier to operate CLEANING THE AIR FILTER Remove the filter every two weeks based on normal operat ing conditions Remove the filter from the top of the unit Figure 1 or to remove the filter remove reservoir then pull filter downwards Figure 2 Wash the filter with clean water then dry Re ...

Page 13: ...m temperature is too low below 41 F 5 C There is a kerosene heater or something giving off water vapor in the room The unit makes a loud noise when operating The air filter is clogged The unit is tilted instead of upright as it should be The floor surface is not level Frost appears on the coils This is normal The dehumidifier has an auto defrost feature Water on floor Hose to connector or hose con...

Reviews: