FRonT panel oveRvIeW:

The following diagram and legend shows the functions of the front operating panel . Some functions are 

only available on select models .
When you push the button to change operation modes, the unit will make a beep sound to indicate that it 

is changing modes .

1) Continuous Button

Press to activate continuous dehumidifying mode.

2) Filter Button

The check filter indicator is a feature to remind you clean 
the air filter for more efficient operation. The filter light will 
illuminate after 250 hours of operation. Toreset after cleaning 
the filter, press the filter button and the light will go off.

3) Fan speed Button

Control fan speed. Press to select either high or normal fan 
speeds. Set the fan speed to high for maximum moisture 
removal. When the humidity is reduced or quiet operation is 
preferred, set the fan speed to normal.

4) power Button

Turns the unit on and off.

5/7) Up (+) & Down (–) Buttons 

The relative humidity (RH) can be set within a range of 35% 
to 85% in 5% increments. For drier air, press the pad and set a 
lower percentage value (%). For damper air, press the pad and 
set a higher percentage value (%).

6) Timer Button

Activate the unit for a set period of time, increased and 
decreased using the + and – buttons

DIsplay: 

Shows the set % humidity level from 35% to 85% or auto start/stop time (0~24) while setting, then shows 

the actual (5% accuracy) room % humidity level in a range of 30% RH (Relative Humidity) to 90%RH (Rela-

tive Humidity) .

eRRoR CoDes anD pRoTeCTIon CoDes:

AS) Humidity sensor error—Unplug the unit and plug it back in . If error repeats, call for service .
ES) Temperature sensor error—Unplug the unit and plug it back in . If error repeats, call for service .
P2- Reservoir is full or reservoir is not seated correctly—Empty the reservoir and replace it in the right 

position .
EC) Unit malfuction—Please make sure whether the enviroment temperature is suitable for the stated 

temperature in the manual or not . If not, please operate the unit under the stated temperature . If the 

enviroment temperature is suitable for the stated temperature, please call for service .

Summary of Contents for IDM-40SE

Page 1: ...1 Impecca Dehumidifier Users Manual IDM 40SE 40 Pint Dehumidifier EnergyStar IDM 70SE 70 Pint Dehumidifier EnergyStar...

Page 2: ...here electronic waste can be disposed of at least free of charge to the user B When buying a new product the retailer will take back the old product at least free of charge C The manufacturer will tak...

Page 3: ...his manual may cause harm or damage The seriousness is classified by the following indications IMPORTANT Always contact an authorized service technician for repair or maintenance of this unit This deh...

Page 4: ...death WaRnInG FoR yoUR saFeTy Do not store or use gasoline or other flammable vapors liquids in the vicinity of this or any other appliance Avoid fire hazard or electric shock Do not use an extension...

Page 5: ...e water may splash onto the unit Place the unit on a level sturdy section of the floor Lack of ventilation can cause overheating and fire Water may enter the unit and degrade the insulation It may cau...

Page 6: ...ter reservoir 6 Handle both sides 1 Drain hose outlet 2 Rolling casters 3 Power cord and plug 4 Band used only when storing unit 5 1 2 3 4 6 1 2 3 NOTE All drawings in this manual are for illustrative...

Page 7: ...ent moisture damage anywhere books or valuables are stored Use the dehumidifier in a basement to help prevent moisture damage The dehumidifier must be operated in an enclosed area to be most effective...

Page 8: ...to the unit Banging the reservoir against anything or failing to push it in securely may cause the unit to stop operating If water spills or is found within the unit upon removing the reservoir you mu...

Page 9: ...RH can be set within a range of 35 to 85 in 5 increments For drier air press the pad and set a lower percentage value For damper air press the pad and set a higher percentage value 6 Timer Button Act...

Page 10: ...he unit will restart with the previous function settings automatically when power returns TIMER FUNCTION The timer indicator lights are for two separate functions one to automatically turn the unit on...

Page 11: ...ely closed Room temperature is too low below 41 F 5 C There is a kerosene heater or something giving off water vapor in the room The unit makes a loud noise when operating The air filter is clogged Th...

Page 12: ...hwasher to clean the reservoir After cleaning the reservoir must be in place and securely seated for the dehumidifier to operate CLEANING THE AIR FILTER Remove the filter every two weeks based on norm...

Page 13: ...11 Manual de Usuario de Des humidificador Impecca IDM 40SE 40 Pint Dehumidifier EnergyStar IDM 70SE 70 Pint Dehumidifier EnergyStar...

Page 14: ...e la basura electr nica se puede desechar sin cargo alguno para el usuario B Cuando se compra de un producto nuevo el minorista puede retirar el producto viejo incluso de forma gratuita C El fabricant...

Page 15: ...siguientes instrucciones y precauciones de seguridad El incumplimiento de las instrucciones y precauciones mencionadas en este manual puede causar lesiones o da os Su gravedad se clasifica mediante l...

Page 16: ...No guarde ni use gasolina u otros l quidos o vapores l quidos en las proximidades de este o cualquier otro electrodom stico Evite el riesgo de incendio o descarga el ctrica No utilice un cable de exte...

Page 17: ...s No la ponga en lugares donde el agua pueda salpicar sobre la unidad Ponga la unidad en una secci n del suelo nivelada y fuerte La falta de ventilaci n puede causar reca lentamiento e incendio El agu...

Page 18: ...6 Asas ambos lados 1 Salida para la manguera de drenaje 2 Rueditas 3 Cable de alimentaci n y enchufe 4 Banda s lo se utiliza cuando para el almacenamiento de la unidad 5 1 2 3 4 6 1 2 3 NOTA Todas las...

Page 19: ...ara evitar da os por humedad en libros o art culos de valor Utilice el des humidificador en un s tano para ayudar a prevenir da os por humedad El des humidificador debe utilizarse en un rea cerrada pa...

Page 20: ...ede hacer que la unidad deje de funcionar Si se derrama agua o encuentra dentro de la unidad al retirar el dep sito se debe secarla 2 DRENAJE CONTINUO El agua puede desecharse autom ticamente hacia un...

Page 21: ...seleccione un valor de mayor porcentaje 6 Bot n del Temporizador Activa la unidad durante un per odo de tiempo determinado se aumenta y se disminuye usando los botones y PANTALLA Muestra el del nivel...

Page 22: ...ajustes de las funciones anteriores cuando se restablezca el suministro el ctrico FUNCI N DE TEMPORIZADOR Las luces del indicador del temporizador son para dos funciones distintas una para apagar aut...

Page 23: ...eratura ambiente es demasiado baja por debajo de 41 F 5 C Hay un calentador de queroseno o algo que emiten vapor de agua en la habitaci n La unidad hace un ruido fuerte cuando est funcionando El filtr...

Page 24: ...o Despu s de la limpieza el dep sito debe ponerse en su lugar y asegurarlo para que el des humidificador funcione LIMPIEZA DEL FILTRO DE AIRE Retire el filtro cada dos semanas seg n las condiciones no...

Reviews: