Electrical wiring on your unit is not required as the unit has

been wired at the factory. For your future reference, the wiring

diagram in Figure 7 shows rocker switches, two-speed motor,

capacitor and pump.

The cooling pads should be replaced with fresh aspen fiber

at least once a year, at the beginning of each cooling season. 

The need to change pads varies with locality and how much

dust, alkali and other foreign matter accumulates in pads. If

cooling efficiency is impaired, it may be desirable to change

pads several times during a cooling season.

Replacement Instructions:

To remove pad assemblies from the unit, lift up, pull out and 

then down. Lay the metal side down on a flat surface and 

remove the pad retainers. The aspen filters can now be removed.

Rinse off pad assembly, then install new aspen filter and retainer.

Replacement filter pads are available at your cooler dealer.

ELECTRICAL

COOLING PAD REPLACEMENT

GREEN (GROUND WIRE)

GREEN (GROUND  WIRE)

GREEN (GROUND WIRE)

GREEN (GROUND WIRE)

NEUTRAL (WHITE WIRE)

HOT (BLACK WIRE)

HOT HIGH SPEED (BLACK WIRE)

HOT LOW SPEED (RED WIRE)

NEUTRAL (WHITE WIRE)

NEUTRAL (WHITE WIRE)

MOTOR

WIRE NUT

PLUG

PUMP

PUMP SWITCH

GROUND SCREWS (ISOLATED CORD GROUND)

WIRING DIAGRAM

MOTOR SWITCH

HOT (BLACK WIRE)

Dimensions (in)

Water Capacity

Shipping

Weight

A

B

C

D

22

19

23.6

29

4.5 Gallons

65 lb

SPECIFICATIONS AND DIMENSIONS

Motor

Frequency

Volts

Current

1/8 HP

60 Hz

120 V~

3.6 A 

Picture 7

Picture 8

Picture 9

Picture 10

Figure 7

Summary of Contents for Mobile Symphony SPM20

Page 1: ...tar problemas en su enfriador La falla en seguir estas instrucciones puede da ar y o afectar la operaci n del enfriador y anular la garant a U S Models SPM20 SPM30 SPM45 CAUTION SAVE AND READ THESE IM...

Page 2: ...Always unplug the electric cord to your cooler before you work on the cooler Your cooler will run on 120 Volt AC 60 Hz cycle current only Plug into three prong grounded GFCI protected electrical rece...

Page 3: ...ated on level ground Connect to a water supply using a commercial grade garden hose supplied by customer connected to the adapter on the float valve and turn on the water Verify water tight connection...

Page 4: ...fting the pad frames up and out of the cooler Remove pump from cooler To prevent breakage carefully release the four snap out tabs and lift impeller base plate from the pump body Picture 5 Use a mild...

Page 5: ...emblies from the unit lift up pull out and then down Lay the metal side down on a flat surface and remove the pad retainers The aspen filters can now be removed Rinse off pad assembly then install new...

Page 6: ...email customerservice impcollc com Website www impcollc com 5...

Page 7: ...is level D Pump not working D Clean or replace pump E Loose water connections E Check for leaks and correct Water draining from cooler 1 Float arm improperly adjusted 1 Adjust float to proper level 2...

Page 8: ...on any exchange e This specific warranty does not cover evaporative coolers installed and operated outside the continental United States III Do not use cooler cleaners cooler treatments or other addi...

Reviews: