WARNINGS AND SAFETY RULES

!

INTRODUCTION

Evaporative cooling works on the principle of heat absorption

by moisture evaporation. Simply put, heat is removed from the

air as water evaporates. You feel this principle in action when

you step out of a swimming pool or shower; you feel immedi-

ately cooler as water evaporates from the surface of your skin.

Your evaporative cooler works on the same principle. Hot out-

side air is pulled through water-saturated pads, where the air is

cooled by evaporation and then discharged from the cooler.

WARNING…

To reduce the risk of electric shock, fire or injury:

Read instructions and labels carefully.

Always unplug the electric cord to your cooler before

you work on the cooler.

Your cooler will run on 120 Volt AC, 60 Hz (cycle)

current only.

Plug into three-prong grounded GFCI protected

electrical receptacle only.

Do not operate if plug or cord are damaged in any way.

Do not step on or roll over power cord with heavy or

sharp objects.

Do not operate unit unless all panels are securely in

place.

Remove the plug from the electrical receptacle by

pulling on the plug and not the cord.

Test the GFCI receptacle or breaker monthly to ensure

it is functioning properly.

Do not operate near open containers of flammable

liquids or gases.

Never wash your cooler cabinet with a garden hose;

water may harm the motor and pump.

If the unit is damaged or it malfunctions, do not contin-

ue to operate it. Refer to the warranty or troubleshooting

section at www.impcollc.com

Other Symphony Units

Hi Cool

R28RTE

Summary of Contents for Mobile Symphony SPM20

Page 1: ...tar problemas en su enfriador La falla en seguir estas instrucciones puede da ar y o afectar la operaci n del enfriador y anular la garant a U S Models SPM20 SPM30 SPM45 CAUTION SAVE AND READ THESE IM...

Page 2: ...Always unplug the electric cord to your cooler before you work on the cooler Your cooler will run on 120 Volt AC 60 Hz cycle current only Plug into three prong grounded GFCI protected electrical rece...

Page 3: ...ated on level ground Connect to a water supply using a commercial grade garden hose supplied by customer connected to the adapter on the float valve and turn on the water Verify water tight connection...

Page 4: ...fting the pad frames up and out of the cooler Remove pump from cooler To prevent breakage carefully release the four snap out tabs and lift impeller base plate from the pump body Picture 5 Use a mild...

Page 5: ...emblies from the unit lift up pull out and then down Lay the metal side down on a flat surface and remove the pad retainers The aspen filters can now be removed Rinse off pad assembly then install new...

Page 6: ...email customerservice impcollc com Website www impcollc com 5...

Page 7: ...is level D Pump not working D Clean or replace pump E Loose water connections E Check for leaks and correct Water draining from cooler 1 Float arm improperly adjusted 1 Adjust float to proper level 2...

Page 8: ...on any exchange e This specific warranty does not cover evaporative coolers installed and operated outside the continental United States III Do not use cooler cleaners cooler treatments or other addi...

Reviews: