background image

 

ATTENTION 

It shows the procedures that can damage seriously the machine if they are not 
followed carefully 

 

DANGER 

It shows the procedures that can be dangerous to the operator if they are not 
followed carefully 

 

1.2  IDENTIFICATION 

 
MANUFACTURER IDENTIFICATION:    

See the cover page

 

MACHINE IDENTIFICATION:       

See the plate on the machine where the complete 
identification data are to be found. 

 

1.3  APPLICATIONS 

 
This appliance has been studied to determine the consistency of a soil sample under fixed conditions of 
load, time and temperature. The penetration is expressed in distance of tenths of millimetres vertically 
penetrated by a standard needle.  

 

The equipment is made for the aim, which it has been conceived for. Any other uses are not allowed. 

 

ATTENTION 

The instructions given in this operating manual are only made for the right use of the 
appliance. To carry out the test in the right way, the user must refer to the specific 
standards in force for the test itself.  

 

1.4  STRUCTURE AND OPERATING OF THE APPLIANCE  

 

The penetrometer is formed by:  
 

A base table in light alloy with levelling  screws; 

A plated vertical rod; 

Micrometric vertical adjustment device; 

A brass slider with free fall; 

a graduated dial 360° (division 0,1 mm) with a diameter of 150 mm; 

set of weights 50 and 100 g; 

a penetration needle; 

brass sample cups :  diameter 55 × 35 mm and 70 × 45 mm; 

 

For further info. contact the dealer or the manufacturer. 

 
 

 
 
 
 
 
 

Chapter 2 

SAFETY INFORMATION 

 

2.1  GENERAL SAFETY STANDARDS  

 

• 

The use, lifting, installation, maintenance and scrapping of the machine are allowed only to qualified staff.

 

Qualified staffs are composed by people who are authorised by the safety responsible to do any activities 
due to their experience and acknowledgement of the operating of the machine and of the standards, rules 
and actions. 
The user must be carefully taught about the operating of the machine to avoid any misuse of it and about 
the safety devices, which the machine could be eventually equipped with. The safety devices will have to 
be kept always assembled and to be daily checked. 

The manufacturers offer training and assume no liability for any damages due to a misuse of the machine 

by an unskilled staff. 

 

 

Summary of Contents for SL190

Page 1: ...User Guide User Guide Penetrometer SL190 Impact Test Equipment Ltd www impact test co uk www impact test com...

Page 2: ...t Ltd Building 21 Stevenston Ind Est Stevenston Ayrshire KA20 3LR T 01294 602626 F 01294 461168 E sales impact test co uk Test Equipment Web Site www impact test co uk Test Sieves Accessories Web Site...

Page 3: ...LEARNING THIS MANUAL IN ALL ITS PARTS GENERAL INDEX Chapter 1 GENERAL INFORMATION 1 1 GENERAL INFORMATION 1 2 IDENTIFICATION 1 3 APPLICATIONS 1 4 STRUCTURE AND OPERATING OF THE MACHINE Chapter 2 SAFE...

Page 4: ...1 GENERAL INFORMATION 1 1 GENERAL FEATURES This manual id addressed to the carrier the installer the user the maintenance operator the scrapping operator Please read it carefully because it informs y...

Page 5: ...RATING OF THE APPLIANCE The penetrometer is formed by A base table in light alloy with levelling screws A plated vertical rod Micrometric vertical adjustment device A brass slider with free fall a gra...

Page 6: ...ety standards or if the instructions of this manual are not followed 2 3 DANGEROUS PARTS AND RESIDUAL RISK The dangerous place is the space inside and around the appliance where the operator could be...

Page 7: ...ay attention to avoid impacts and turnovers of the packing ATTENTION Protect the machine from the atmospheric agents Water and humidity could oxidise it damaging it seriously 3 2 UNPACKING After remov...

Page 8: ...y Official Calibration Institutes ATTENTION The actual standards foresee the calibration check after each single moving of the machine Once it has been installed and it is ready to work before using i...

Page 9: ...e tested and are delivered together with the appliance DESCRIPTION OF PARTS ENCLOSURE B DETAIL OF THE APPLIANCE B1 FIXING SCREW B2 SET OF WEIGHTS B3 ADJUSTMENT KNOB B4 MACHINE BODY B5 FIXING HANDLE B1...

Page 10: ...he procedure described hereunder carefully read and learn the instructions given in this manual Here follows a standard procedure allowing even to an operator without a wide experience to use the pene...

Page 11: ...facturer Chapter 8 DIAGNOSIS Some easy to solve and simple problem which can happen during the working of the appliance are introduced in this chapter ATTENTION All maintenance checking control and re...

Page 12: ...ENCLOSURE B DETAILS OF THE APPLIANCE...

Page 13: ......

Reviews: