Wall mounting 

Never mount the unit on a wet wall, the monitor is intended for indoor use only 

disconnect the power before wall mounting the monitor 

The monitor has a molded cut-out on the reverse side, this is used for single point mounting on a 

screw protruding from the wall, simply hook the monitor over the screw making sure it’s latched 

on properly, if extra stability is required two further through hole mountings are available behind 

the lower cover. 

General information 

Large Liquid crystal display: 

This indicates detected gas concentration. 

Observe display for gas level detected. 

Alarm LED: 

This indicates a level above the pre-set alarm level has been reached

Alarm sounder: 

This activates when the alarm state is reached giving a high pitched 

continuous tone. 

Sensor malfunction LED: 

This alerts the user that a variation away from normal parameters 

has been detected: the monitor may continue to function if this occurs please contact your 

supplier for service. 

Operation 

Following an initial warmup period of 3 minutes, providing the sensor malfunction warning is not 
indicating a fault, the instrument is ready for use. 

Other than periodical observation of the display, no other action is necessary by the user, it is 

important to remember that no alarm is possible in the event of a power failure. 

Under no circumstances should the monitor be used if the Sensor malfunction light is activated, 
in the case of a sensor malfunction discontinue use of the instrument and contact your supplier. 

Summary of Contents for BM350

Page 1: ...m User Guide User Guide www impact test com www impact test co uk www impact testsets co uk Methylene Chloride Monitor BM350 Impact Test Equipment Ltd www impact test co uk www impact test com www imp...

Page 2: ...st Equipment Ltd Building 21 Stevenston Ind Est Stevenston Ayrshire KA20 3LR T 01294 602626 F 01294 461168 E sales impact test co uk Test Equipment www impact test co uk Test Sieves Accessories www im...

Page 3: ...oduct description and safety features Installation instructions Power connection Relay connection and mounting location General information and operation Additional Information re sensor performance M...

Page 4: ...requirements The monitor incorporates three fuses one domestic 3 amp plug head fuse and one internal circuit board mounted 1A time delay fuse and one 2A fuse to protect the alarm relay If required an...

Page 5: ...use the monitor Although every effort is made to ensure accuracy this manual may contain technical unintentional technical inaccuracies On behalf of its clients Impact reserve the right to modify the...

Page 6: ...sary where no socket outlet is present firstly ensure the mains lead is not connected isolate the plug so it cannot be connected accidentally loosen the two screws holding the lower cover in place rem...

Page 7: ...he monitor alarm circuit is muted and the displayed reading is held low this is a normal and necessary part of installation after a short time the reading should settle down close to zero any reading...

Page 8: ...evel has been reached Alarm sounder This activates when the alarm state is reached giving a high pitched continuous tone Sensor malfunction LED This alerts the user that a variation away from normal p...

Page 9: ...f the sensor is exposed in extreme conditions such as very high humidity high temperatures or high contamination levels of organic vapours or other gases for a long period of time sensor performance m...

Page 10: ...tests humidity temperature dust etc calibration should occur at least once a year The site manager is responsible for implementing the safety procedures on his site Impact is not responsible for impl...

Page 11: ...e 0 199ppm 0 2000mg m 3 Dimensions 210 x 185 x 110 mm Accuracy 10 Cal level Visual alarm Red alarm led Weight 0 4kg Audio alarm Integrated sounder Response time 30 Seconds Typical 100 ppm Malfunction...

Reviews: