AC
G
8 2
01
8.
01
e
n-
G
B
, I
D
-No
.: 1
63
-0
43
/A
www.imo.se
26
T.
• Slowly lower the electric motor with the con-
necting frame towards the pump until the stop
bolts touches the frame.
• Avoid side forces that could damage the mag-
nets as it is crucial that the package is connect-
ed in a straight line
NOTE: The magnetic forces are very high at
this point and can easily cause severe inju-
ries DO NOT EVER PUT YOUR FINGERS
OR HANDS BETWEEN THE CONNECTING
FRAME AND THE PUMP AS AN ACCI-
DENTAL SLIP DOWNWARDS EASILY CAN
CRUSH A HAND OR EVEN CUT A FINGER.
U.
• Unscrew the stopping bolts and allow the pump
to completely join with the electrical motor/con-
necting frame
• Avoid side forces that could damage the mag-
nets as it is crucial that the package is connect-
ed in a straight line
• Unscrew the last part of the guide pins.
NOTE: The magnetic forces are very high at
this point and can easily cause severe injuries
DO NOT EVER PUT YOUR FINGERS OR
HANDS BETWEEN THE CONNECTING
FRAME AND THE PUMP AS AN ACCI-
DENTAL SLIP DOWNWARDS EASILY CAN
CRUSH A HAND OR EVEN CUT A FINGER.