Zeus Maior 24 Instructions 

Lack of water in boiler.  

Periodically check the system water pressure.  

Make sure that the pressure in the system is between 1 

and 1.2 bar.  N.B. Close the filling valve on completion.  If pressure valves reach around 3 bar the safety 
valve may be activated.   In this case contact a service technician for assistance.  In the event of frequent 
pressure drops, contact your plumber to eliminate system leakage. 
 

System flow NTC sensor fault

If a problem is detected with the system delivery NTC sensor, the boiler will not start; call a qualified techni-
cian. 
 

Domestic circuit NTC sensor fault

.  

If the unit detects an problem in the domestic circuit NTC sensor, the boiler will not produce domestic hot 
water; call a qualified technician. 
 

No water circulating.  

This occurs if there is overheating in the boiler due to insufficient water circulation through the boiler -

 check 

that shutoff valves are not closed and that the system is free of air .  Check that the circulating pump is run-

ning freely.  If necessary, remove the pump cover screw and manually rotate the pump impellor using a flat 

bladed screwdriver.  

If lockout occurs repeatedly, contact a qualified technician for assistance. 

 

Draining the system

To drain the boiler, use the special drain cock.  Before draining, ensure that the filling valve is not con-
nected. 
 

Draining the DHW tank. 

To drain the tank, use the special drain cock.  N.B.: Before carrying out this operation, close the tank cold 
water inlet cock and open any domestic circuit hot water cock to allow air to enter the tank. 
 

Anti-freeze protection. 

The boiler comes standard with an anti-freeze function that starts the pump and burner when the water tem-
perature inside the boiler falls below 4°C and stops on exceeding 42°C. The anti-freeze function is opera-
tional if the boiler is in normal mode and not in “lockout” status, and is electrically connected with the main 
switch is set to Summer or Winter.   To avoid continued operation in the event of prolonged absence, the 
system should be drained completely or anti-freeze should be added to the heating system water. In both 
cases the boiler domestic water circuit must be drained. In appliances subject to frequent draining, the sys-
tem must be refilled with suitably treated water.  Do not use hard water to fill the system or there will be 
scale formation in the boiler. 
 

Casing Cleaning: 

Use damp cloths and neutral 
 detergent to clean the boiler casing.  Never use abrasive or powder  
detergents. 

Maintenance Operations 

Summary of Contents for Zeus Maior 24

Page 1: ...ith Unvented Hot Water Storage For technical assistance spare parts or service call RVR Limited Kenmare Co Kerry Tel 064 41344 Fax 064 89520 Read these instructions completely before using or installi...

Page 2: ...ns These include but may not be limited to the follow ing I S 813 Domestic Gas Installations I S 820 Non Domestic Gas Installations All relevant Building Regulations Local Water Bye Laws IEE Wiring Re...

Page 3: ...r C 20 60 Hot water storage capacity L 60 Continuous hot water flow rate T 30oC l min 13 9 Boiler weight filled kg 138 Boiler weight empty kg 74 ELECTRICAL Electrical connection v hz 230 50 Nominal Ab...

Page 4: ...hamber 18 Over temperature Safety thermostat 6 Burner 19 Boiler 316L stainless steel 7 Circulating Pump 20 Domestic Circuit 8 Bar Safety Valve 8 Gas Valve 21 Boiler Drain Valve 9 Motor operated 3 way...

Page 5: ...e pin plug and unswitched shuttered socket outlet both complying with BS 1363 or a fused double pole switch with a contact separation of at least 3 mm in both poles Wiring external to the boiler must...

Page 6: ...Over 3 Diaphragm Flue length in metres 44 0 5 47 5 8 None Over 8 Diaphragm Flue length in metres 44 0 17 47 17 24 None Over 24 Flue System When the boiler is installed on an external wall the standar...

Page 7: ...tical metres Vertical concentric kit 80 125 The exhaust pipe 80 mm is fitted inside the Air intake pipe 125 mm Connection to the boiler is made using a flange 1 The adapter 60 100 80 125 3 is used the...

Page 8: ...bles The resistance factor varies depending on whether the component in question conveys fresh inlet air or hot combustion gases All boilers have a maximum resistance factor of 100 The sum of all comp...

Page 9: ...ces Component Resistance Quantity Total 80mm Intake pipe 2 3 9 20 7 90 air intake bend 5 3 15 80mm Flue pipe 3 6 18 90 Flue bend 6 5 3 19 5 73 2 Total Flue Resistance In this case the total resistance...

Page 10: ...terminal is fitted less than 2 m above a surface to which people have access the terminal must be protected by a terminal guard IMPORTANT Failure to install flue systems correctly may lead to serious...

Page 11: ...low To check correct operation of the expansion vessel s the system pressure should not be more than 2 5 bar when the system is at maximum operating temperature The boiler is supplied with the followi...

Page 12: ...2879 must be used to allow the system to be completely drained The heating system should be thoroughly flushed before the boiler is connected and again after the first heating If it is necessary to a...

Page 13: ...which is present at the top of the 60l storage vessel provides sufficient expansion for the domestic hot water system An optional additional DHW expansion kit is avail able for situations where the in...

Page 14: ...iven to the installation of an electronically operated device to warn when discharge takes place High Level Termination At high level discharge onto a roof is acceptable pro viding the roof is capable...

Page 15: ...supply to the boiler Turn main switch 5 to Hot Water or Hot Water Heating N B Once the main switch 5 is turned to the central Heating temperature setting 1 is not active and the domestic water temper...

Page 16: ...dly contact a qualified technician for assistance Draining the system To drain the boiler use the special drain cock Before draining ensure that the filling valve is not con nected Draining the DHW ta...

Page 17: ...s on the gauge Ensure activation of the device for protection against the ionisation flame control gas activation time must be less than ten seconds Visually inspect to check for leakage of water or o...

Page 18: ...Zeus Maior 24 Instructions Zeus Maior 24 Series Variable Heat Output Zeus Maior 24 Wiring Diagram...

Reviews: