Zeus Maior 24 Instructions 

An annual maintenance of the boiler and heating system is recommended.  This ensures that the optimal 
safety, performance and operation characteristics of the boiler remain unchanged over time.  

 
Warnings 

Never expose the wall-mounted boiler to direct vapours from a cooking surface. Use of the boiler by un-
skilled persons or children is strictly prohibited. 
Never touch the flue extraction terminal (if fitted) due to the risk of burning caused by high temperatures; 
For safety purposes, check that the concentric air intake/flue exhaust terminal (if fitted), is not blocked. If 
temporary shutdown of the boiler is required, proceed as follows: 
a) drain the heating system if anti-freeze is not used; 
b) shut off all electrical, water and gas supplies. 
When building or renovation work is carried out in the vicinity of the flue outlet, switch off the boiler and on 
completion of work ensure that a qualified technician checks the safety of the installation.  Never clean the 
appliance or connected parts with flammable substances. Never leave containers or flammable substances 
in the same environment as the appliance. 
 

Electrical Safety

 

- never touch the appliance with wet hands or other parts of the body and never touch when barefoot. 
- never pull electrical cables or leave the appliance exposed to atmospheric agents (rain, sunlight, etc.); 
- the appliance power supply cable must never be replaced by the user; 
- in the event of damage to the cable, switch off the appliance and contact a qualified service technician. 
- in the event of prolonged periods when the boiler is not in use, turn off the main power switch. 

Operation and Maintenance Instructions 

Using the Boiler 

Before lighting, make sure  that the system is full of  water and that the  manometer (8) indicates a pressure 
of 1 - 1.2 bar. 
-Open the gas valve on the gas supply to the boiler. 
-Turn main switch (5) to Hot Water or Hot Water/Heating. 

N.B.: 

Once the main switch (5) is turned to        the central Heating temperature setting (1) is not active, 

and the domestic water temperature is controlled by selector (2). With the switch set to             the central 
heating temperature is set using selector (1) while selector (2) is used for the domestic hot water.  Turn the 
selectors clockwise to raise the temperature, anticlockwise to lower it. Boiler operation is now automatic.  

Faults 

Overheat lockout 

- Red indicator lamp (3)on. If during operation a fault causes the temperature to exceed 

100°C.the boiler enters this condition. Turn the main switch (5) temporarily to the Reset position. If this con-
dition occurs repeatedly, contact a qualified technician for assistance. 

Flue blockage 

- Red indicator lamp (3) on. If there is a problem with the boiler flue then the boiler enters 

‘flue blockage’ mode.  Turn the main switch (5) temporarily to the Reset position. If this condition occurs 
repeatedly, contact a qualified technician for assistance. 

Ignition lockout 

- Red indicator lamp (6) on. Each time heating or hot water production is required the 

boiler lights automatically. If the boiler does not light within 10 seconds, the boiler goes to “ignition lock-
out” (indicator lamp 6 on).  Turn the main switch (5) temporarily to the Reset position.   This condition may 
occur repeatedly if the gas supply is interrupted or if the boiler has been out of service for some time.  If this 
condition occurs repeatedly, contact a qualified technician for assistance. 
 

Boiler shutdown. 

Turn off the main switch (5) by turning it to “0” (yellow indicator lamp 4 off) and close the 

gas supply valve upstream of the appliance. Never leave the boiler switched on if left unused for prolonged 
periods. 

1 Heating Temp Selector 
2 Domestic Hot Water Selector   
3 Boiler over temperature and flue 
block red indicator 
4 Power on green indicator lamp 
5 0-Domestic—Domestic and Heat-
ing– Reset switch 
6 Ignition lockout red indicator lamp 
7 Boiler Thermometer 
8 Boiler Manometer 

Summary of Contents for Zeus Maior 24

Page 1: ...ith Unvented Hot Water Storage For technical assistance spare parts or service call RVR Limited Kenmare Co Kerry Tel 064 41344 Fax 064 89520 Read these instructions completely before using or installi...

Page 2: ...ns These include but may not be limited to the follow ing I S 813 Domestic Gas Installations I S 820 Non Domestic Gas Installations All relevant Building Regulations Local Water Bye Laws IEE Wiring Re...

Page 3: ...r C 20 60 Hot water storage capacity L 60 Continuous hot water flow rate T 30oC l min 13 9 Boiler weight filled kg 138 Boiler weight empty kg 74 ELECTRICAL Electrical connection v hz 230 50 Nominal Ab...

Page 4: ...hamber 18 Over temperature Safety thermostat 6 Burner 19 Boiler 316L stainless steel 7 Circulating Pump 20 Domestic Circuit 8 Bar Safety Valve 8 Gas Valve 21 Boiler Drain Valve 9 Motor operated 3 way...

Page 5: ...e pin plug and unswitched shuttered socket outlet both complying with BS 1363 or a fused double pole switch with a contact separation of at least 3 mm in both poles Wiring external to the boiler must...

Page 6: ...Over 3 Diaphragm Flue length in metres 44 0 5 47 5 8 None Over 8 Diaphragm Flue length in metres 44 0 17 47 17 24 None Over 24 Flue System When the boiler is installed on an external wall the standar...

Page 7: ...tical metres Vertical concentric kit 80 125 The exhaust pipe 80 mm is fitted inside the Air intake pipe 125 mm Connection to the boiler is made using a flange 1 The adapter 60 100 80 125 3 is used the...

Page 8: ...bles The resistance factor varies depending on whether the component in question conveys fresh inlet air or hot combustion gases All boilers have a maximum resistance factor of 100 The sum of all comp...

Page 9: ...ces Component Resistance Quantity Total 80mm Intake pipe 2 3 9 20 7 90 air intake bend 5 3 15 80mm Flue pipe 3 6 18 90 Flue bend 6 5 3 19 5 73 2 Total Flue Resistance In this case the total resistance...

Page 10: ...terminal is fitted less than 2 m above a surface to which people have access the terminal must be protected by a terminal guard IMPORTANT Failure to install flue systems correctly may lead to serious...

Page 11: ...low To check correct operation of the expansion vessel s the system pressure should not be more than 2 5 bar when the system is at maximum operating temperature The boiler is supplied with the followi...

Page 12: ...2879 must be used to allow the system to be completely drained The heating system should be thoroughly flushed before the boiler is connected and again after the first heating If it is necessary to a...

Page 13: ...which is present at the top of the 60l storage vessel provides sufficient expansion for the domestic hot water system An optional additional DHW expansion kit is avail able for situations where the in...

Page 14: ...iven to the installation of an electronically operated device to warn when discharge takes place High Level Termination At high level discharge onto a roof is acceptable pro viding the roof is capable...

Page 15: ...supply to the boiler Turn main switch 5 to Hot Water or Hot Water Heating N B Once the main switch 5 is turned to the central Heating temperature setting 1 is not active and the domestic water temper...

Page 16: ...dly contact a qualified technician for assistance Draining the system To drain the boiler use the special drain cock Before draining ensure that the filling valve is not con nected Draining the DHW ta...

Page 17: ...s on the gauge Ensure activation of the device for protection against the ionisation flame control gas activation time must be less than ten seconds Visually inspect to check for leakage of water or o...

Page 18: ...Zeus Maior 24 Instructions Zeus Maior 24 Series Variable Heat Output Zeus Maior 24 Wiring Diagram...

Reviews: