Immergas VICTRIX ZEUS SUPERIOR 26 2 ERP Instruction And Recomendation Booklet Download Page 20

20

2-1

INS

TALLER

US

ER

MAINTEN

AN

CE TECHNI

CI

AN

Key:

 

  -  Stand-by - On Button

 

A

 -  Summer 

( )

 and winter 

( ) 

operating mode button

 

B

  -  DHW priority button 

( )

 

C

 -  Reset 

(RESET)

 / exit menu 

(ESC) 

 button

 

D

  -  Menu entry button (

MENU

)/ data confirmation 

(OK)

 button

  1  -  Domestic hot water temperature selector

  2  -  Domestic hot water temperature set

  3  -  Central heating temperature selector

  4  -  Central heating temperature set

  4  - Presence of anomalies

  6  - Display of boiler functioning status

  8  - Flame presence symbol and relative power scale

9 and 7 -  Primary heat exchanger outlet water temperature

  10  - Boiler in stand-by

  11  - Boiler connected to remote control (Optional)

  12  - Functioning in summer mode

  13  - Antifreeze function in progress

  14  - Functioning in winter mode

  15  - Domestic hot water priority functioning active

  16  - Presence of external connected devices

  17  - Display of menu items

  18  - Functioning with external temperature probe active

  19  - Display of data confirmation or menu access

20 and 7 - Outside temperature display 

       with external probe connected (optional)

  21  - Display of reset or exit menu request

  22  - Chimney sweep function in progress

  23  - Boiler manometer

  24  - Multi-function display

2.3  CONTROL PANEL.

2

  USE AND MAINTENANCE 

INSTRUCTIONS

2.1  CLEANING AND MAINTENANCE.

Attention: 

to preserve the boiler's integrity 

and keep the safety features, performance and 

reliability, which distinguish it, unchanged over 

time, you must at least execute maintenance 

operations on a yearly basis in compliance with 

what is stated in the relative point at “annual 

check and maintenance of the appliance”. 

2.2  GENERAL WARNINGS.

Never expose the wall-mounted boiler to direct 

vapours from cooking hobs.

Use of the boiler by unskilled persons or children 

is prohibited.

For safety purposes, check that the concentric 

air intake/flue exhaust terminal (if fitted), is not 

blocked, even just temporarily.

If temporary shutdown of the boiler is required, 

proceed as follows:

a) drain the water system if antifreeze is not used;
b) shut-off all electrical, water and gas supplies.
In the event of work or maintenance on struc-

tures located in the vicinity of ducting or devices 

for flue extraction and relative accessories, switch 

off the appliance and on completion of operations 

ensure that a qualified technician checks the ef-

ficiency of the ducting or other devices.

Never clean the appliance or connected parts 

with easily flammable substances.

Never leave containers or flammable substances 

in the same environment as the appliance.
• 

Attention:

 the use of components involving use 

of electrical power requires some fundamental 

rules to be observed, such as:

  -  do not touch the appliance with wet or moist 

parts of the body; do not touch when bare-

foot;

  - never pull electrical cables nor leave the ap-

pliance exposed to weathering (rain, sunlight, 

etc.);

  - the appliance power cable must not be re-

placed by the user;

  -  in the event of damage to the cable, switch off 

the appliance and contact exclusively quali-

fied staff for replacement;

  -  if the appliance is not to be used for a certain 

period, disconnect the main power switch.

N.B.:

 the temperatures indicated by the display 

have a tolerance of +/- 3°C due to environmental 

conditions that cannot be attributed to the boiler.
At the end of its service life the appliance must 

not be disposed of like normal household waste 

nor abandoned in the environment, but must be 

removed by a professionally qualified firm. Con-

tact the manufacturer for disposal instructions.

Summary of Contents for VICTRIX ZEUS SUPERIOR 26 2 ERP

Page 1: ...VICTRIX ZEUS SUPERIOR 26 2 32 2 ERP Instruction and recommendation booklet IE 1 037935ENG...

Page 2: ......

Page 3: ...in the regulations in force and principles of good practice In compliance with legislation in force the systems must be designed by qualified professionals within the dimensional limits established b...

Page 4: ...e 20 2 2 General warnings 20 2 3 Control panel 20 2 4 Description of functioning states 21 2 5 Using the boiler 22 2 6 Troubleshooting 23 2 7 Parameters and information menu 25 2 8 Boiler shutdown 26...

Page 5: ...lve must be conveyed away by a draining funnel or if there are leaks from the hydraulic connections on the contrary the manufacturer cannot be held responsible for any damage caused to the household a...

Page 6: ...uid must be followed scrupulously regarding the percentage neces sary with respect to the minimum temperature at which the system must be kept An aqueous solution must be made with potential pollution...

Page 7: ...et the system requirements es tablished by the technical regulation in force in relation to the pollution of drinking water we recommend installing the IMMERGAS anti backflow kit to be used upstream o...

Page 8: ...be set to On Off mode CAR V2 Super CAR or On Off chrono ther mostat electrical connection Optional The operations described below must be performed after having removed the voltage from the appli ance...

Page 9: ...efore varies according to applica tions for air intake or flue exhaust Each single component has a resistance corresponding to a certain length in metres of pipe of the same diameter the so called equ...

Page 10: ...Intake and Exhaust 16 3 m 2 5 Intake m 18 7 Exhaust m 4 9 m 7 7 Exhaust m 13 6 Concentric intake exhaust terminal 60 100 vertical Intake and Exhaust 9 m 1 4 Intake m 10 3 Exhaust m 2 7 m 4 3 Exhaust m...

Page 11: ...in the female end with lip seal of the 80 flange unit until it stops Introduce the gasket making it run along the bend Fix it using the sheet steel plate and tighten by means of the straps present in...

Page 12: ...with the boiler flange and tighten using the screws supplied with the kit Fit the 60 100 3 concentric terminal pipe with the male side smooth to the female side of the bend 2 up to the end stop makin...

Page 13: ...cal length of 14 4 m including the terminal This configuration corresponds to a resistance factor of 100 In this case specific extensions must be requested Vertical kit with aluminium tile 80 125 Kit...

Page 14: ...oth in the female side of the bend 5 up to the end stop ensuring that the internal and external wall sealing plates are fitted Fit the exhaust pipe 9 with the male side smooth to the female side of th...

Page 15: ...ical data The dimensions of the shafts must ensure a minimum gap between the outer wall of the smoke duct and the inner wall of the shaft 30 mm for circular section shafts and 20 mm in the event of a...

Page 16: ...s length is obtained considering the complete 80 exhaust terminal 1m of 80 pipe in ex haust two 90 80 bends on the boiler outlet 1 17 CONFIGURATION TYPE B OPEN CHAMBER AND FAN ASSISTED FOR INDOORS The...

Page 17: ...ervals using the main switch on the control panel Vent the circulation pump by loosening the front cap and keeping the motor run ning Screw the cap back on after the operation 1 21 CONDENSATE TRAP FIL...

Page 18: ...speed varies to maintain the T constant between the system flow and return accord ing to set value K Fixed 100 65 in this mode the cir culator works at constant speed the operating range is defined b...

Page 19: ...e functioning possibilities Cover kit on request If installed outdoors in a partially protected place with direct air intake it is compulsory to mount the appropriate top protection cover for the corr...

Page 20: ...rect vapours from cooking hobs Use of the boiler by unskilled persons or children is prohibited For safety purposes check that the concentric air intake flue exhaust terminal if fitted is not blocked...

Page 21: ...uest for domestic hot water or central heating in order to evacuate residual flue gas F5 Postcirculation in progress Pump in function after a request for domestic hot water or central heating in order...

Page 22: ...ection it decreases During domestic hot water heating DHW ON appears on the display 24 on the status indicator 6 and at the same time as the burner ignites the flame presence indicator switches on 8 w...

Page 23: ...pressure is between 1 1 2 bar and restore the correct pressure if necessary 12 Storage tank probe anomaly The board detects an anomaly on the storage tank probe The boiler cannot produce domestic hot...

Page 24: ...flame signal This occurs when the boiler is ignited correctly and the burner flame switches off unexpectedly a new ignition attempt is performed and if normal conditions are restored the boiler does...

Page 25: ...vels of the menu and the choice of parameters is confirmed Press button C to go back one level M1 information menu This menu contains the various information relative to boiler functioning 1st Level B...

Page 26: ...i freezeliquidandinstallation of the Immergas Anti freeze Kit in the boiler In the case of prolonged inactivity second case we also recommend that disconnect the electric power supply fully drain the...

Page 27: ...efficiency of water circuits check ventilation and or aeration of the instal lation room where provided If even only a single safety check offers a negative result do not commission the system 3 1 PLU...

Page 28: ...ed by the drain trap being blocked Check by means of the condensate drain cap that there are no residues of material blocking the flow of condensate Noise due to air in the system Check open ing of th...

Page 29: ...casing mounted while the gas valve calibration operations must be carried out with the casing open and disconnecting the boiler from the power supply Calibration of the minimum CO2 minimum heating pow...

Page 30: ...on the domestic hot water probe on entry to the boiler P54 2 Displays the temperature read on the domestic hot water probe on exit from the boiler P54 3 Displays the temperature read on the return pr...

Page 31: ...in the cylinder falls by 3 C with respect to the temperature set Solar function deactivated P71 1 P71 2 5 C Boiler ignition for heating the domestic hot water occurs when the water contained in the cy...

Page 32: ...p at least once every 24 hours for the duration of 30 seconds in order to reduce the risk of the pump becoming blocked due to prolonged inactivity 3 11 THREE WAY ANTI BLOCK FUNCTION Both in domestic h...

Page 33: ...that it is properly fixed to the combustion chamber lid otherwise it must be replaced Visually check that the water safety drain valve is not clogged Check that after discharging system pressure and b...

Page 34: ...wer grid 1 by taking out the 4 fastening screws 2 Open the control panel door 3 remove the 2 white screw caps 4 and take out the 2 fasten ing screws 5 tilt the panel towards you Unscrew the 2 6 fasten...

Page 35: ...0 92 9 4 0 81 1 28 13 1 9 0 7740 1 00 0 73 7 4 0 75 0 77 7 9 0 73 1 09 11 1 8 0 6880 0 89 0 59 6 0 0 67 0 64 6 5 0 66 0 90 9 2 7 0 6020 0 78 0 46 4 7 0 59 0 52 5 3 0 58 0 73 7 5 6 0 5160 0 67 0 35 3...

Page 36: ...lue temperature at nominal output C 78 86 79 Flue temperature at minimum output C 73 82 75 Victrix Zeus Superior 32 2 ErP Gas nozzle diameter mm WITHOUT 6 00 6 00 Flue flow rate at nominal heat output...

Page 37: ...xpansion vessel pre charge bar 2 5 2 5 Appliance water content l 6 7 9 1 Head available with 1000 l h flow rate kPa m H2 O 26 0 2 65 29 0 2 95 Hot water production useful heat output kW kcal h 25 8 22...

Page 38: ...r N Serial Number CHK Check Cod PIN PIN code Type Type of installation ref CEN TR 1749 Qnw min Minimum DHW heat input Qn min CH minimum heat input Qnw max DHW maximum heat input Qn max CH maximum heat...

Page 39: ...s 60 C on return and 80 C on flow Low temperature mode for condensation Boilers means 30 C for low temperature boilers 37 C and for other appliances 50 C of return tempera ture Model s Victrix Zeus Su...

Page 40: ...mestic hot water function AFC 18 GJ Seasonal room heating yield s 92 Domestic hot water production yield wh 82 Parameter value Yearly energy consumption for the heating function QHE 61 2 GJ Yearly ele...

Page 41: ...ementary heat pump From fiche of heat pump Solar contribution and Supplementary heat pump Select smaller value Boiler and supplementary heat pump installed with low temperature heat emitters at 35 C F...

Page 42: ...35 C From fiche of heat pump The energy efficiency of the package of products provided far in this fiche may not correspond to its actual energy efficiency once installed in a building as the efficien...

Page 43: ...y electricity 3 G F E D C B A A A A 27 27 27 28 27 27 27 28 30 30 30 32 33 34 35 36 36 37 38 40 39 50 55 60 65 75 80 85 100 115 123 131 130 150 160 170 163 188 200 213 M L XL XXL 3 2 3 2 The energy ef...

Page 44: ...Water heating energy efficiency under colder and warmer climate conditions Colder 0 2 x Warmer 0 4 x Declared load profile Solar contribution From fiche of solar device 1 I 2 1 1 x I 10 x II III I Aux...

Page 45: ...45...

Page 46: ...46...

Page 47: ...47...

Page 48: ...mmergas com Immergas S p A 42041 Brescello RE Italy Tel 0522 689011 Fax 0522 680617 Certified company ISO 9001 This instruction booklet is made of ecological paper Cod 1 037935ENG rev ST 001312 003 12...

Reviews: