Domestic hot water nominal heat input
kW (kcal/h)
28.8 (24773)
Central heating nominal heat input
kW (kcal/h)
24.6 (21194)
Minimum heat input
kW (kcal/h)
4.5 (3862)
Domestic hot water nominal heat output (useful)
kW (kcal/h)
28.3 (24295)
Central heating nominal heat output (useful)
kW (kcal/h)
24.1 (20717)
Minimum heat output (useful)
kW (kcal/h)
4.3 (3689)
*Effective thermal efficiency 80/60 Nom./Min.
%
97.8 / 95.5
*Effective thermal efficiency 50/30 Nom./Min.
%
106.1 / 106.1
*Effective thermal efficiency 40/30 Nom./Min.
%
108.2 / 108.3
Casing losses with burner On/Off (80-60°C)
%
0.29 / 0.20
Chimney losses with burner On/Off (80-60°C)
%
0.02 / 1.70
Central heating circuit max. operating pressure
bar (MPa)
3 (0.3)
Maximum heating temperature
°C
90
Adjustable central heating temperature (min operating field)
°C
20 - 50
Adjustable central heating temperature (max operating field)
°C
55 - 85
System expansion vessel total volume
l
8.0
Expansion vessel pre-charged pressure
bar (MPa)
1.0 (0.1)
Appliance water content
l
5.4
Head available with 1000 l/h flow rate
kPa (m H
2
O)
25.3 (2.6)
Hot water production useful heat output
kW (kcal/h)
28.3 (24295)
Domestic hot water adjustable temperature
°C
30 - 60
Domestic hot water circuit min. pressure (dynamic)
bar (MPa)
0.3 (0.03)
Domestic hot water circuit max. operating pressure
bar (MPa)
10 (1.0)
Flow rate capacity in continuous duty (∆T 30°C)
l/min
14.10
Weight of full boiler
kg
49.0
Weight of empty boiler
kg
43.6
Electrical connection
V/Hz
230 / 50
Nominal power absorption
A
0.88
Installed electric power
W
135
Pump absorbed power
W
59
EEI value
-
≤ 0.20 - Part. 3
Equipment electrical system protection
-
IPX5D
Max temperature of combustion products
°C
75
Max. flue overheating temperature
°C
120
Ambient operating temperature range
°C
-5 ÷ +50
Ambient operating temperature range with optional antifreeze kit
°C
-15 ÷ +50
NO
X
class
-
6
Weighted NO
X
mg/kWh
35.0
Weighted CO
mg/kWh
20.0
**Type of appliance
C13 / C13x / C33 / C33x / C43 / C43x / C53 / C63 / C83 /
C83x / C93 / C93x / B23 / B53p
Category
II 2H3P - I 3P - II 2HM3P