![Immergas VICTRIX TERA VIP Instructions And Warnings Download Page 47](http://html1.mh-extra.com/html/immergas/victrix-tera-vip/victrix-tera-vip_instructions-and-warnings_2047901047.webp)
37
47
INSTALLER
USER
MAINTENANCE TECHNICIAN
3
.5
W
IR
ING
D
IA
G
R
A
M
.
Colour code key:
BK - Black
BL - Blue
BR - Brown
G - Green
GY - Grey
OR - Orange
P - Purple
PK - Pink
R - Red
W - White
Y - Yellow
Y/G - Yellow/Green
Key:
B1 - Flow probe
B2 - DHW probe
B4 - External probe (optional)
B5 - Return probe
B9 - DHW inlet probe (optional)
B10 - Flue probe
CAR
V2
- Comando Amico Remoto
V2
remote
control (optional)
E3 - Ignition and detection electrode
E11 - Aqua Celeris Resistance
M1 - Boiler pump
M20 - Fan
M30 - Three-way motor stepper
S4 - D.H.W. flow switch
S5 - System pressure switch
S20 - Room thermostat (optional)
T2 - Ignition transformer
X40 - Room thermostat jumper
Y1 - Gas valve
Earth
FRAME
230 vac power
supply
50Hz