39
N.B.
- The power data provided in the table is ob-
tained with 0.5 m long intake/exhaust pipe.
- Gas flow rates refer to heating output below a
temperature of 15°C and pressure of 1013 mbar.
- Burner pressure values refer to use of gas at
15°C.
- The number of revs for the fan on the display
is expressed in revs / 50 (Ex.: 1000 revs = 20).
3.25 VARIABLE HEAT OUTPUT.
Victrix Pro 35 2ErP.
METHANE (G20)
PROPANE (G31)
HEAT OUTPUT
HEAT OUTPUT
BURNER GAS FLOW
RATE
REVS
FAN
BURNER GAS FLOW
RATE
REVS
FAN
(kW)
(kcal/h)
(m
3
/h)
(n°)
(kg/h)
(n°)
34,0
29240
3,70
5200
2,71
5050
33,0
28380
3,58
5070
2,63
4910
32,0
27520
3,47
4940
2,54
4780
31,0
26660
3,35
4820
2,46
4640
30,0
25800
3,24
4690
2,38
4510
29,0
24940
3,13
4570
2,30
4380
28,5
24469
3,07
4500
2,26
4310
27,0
23220
2,92
4320
2,14
4120
26,0
22360
2,81
4200
2,06
4000
25,0
21500
2,71
4070
1,99
3870
24,0
20640
2,60
3950
1,91
3750
23,0
19780
2,50
3830
1,83
3620
22,0
18920
2,39
3710
1,76
3500
21,0
18060
2,29
3580
1,68
3380
20,0
17200
2,19
3460
1,61
3260
19,0
16340
2,09
3330
1,53
3130
18,0
15480
1,98
3210
1,46
3010
17,0
14620
1,88
3080
1,38
2890
16,0
13760
1,78
2960
1,31
2770
15,0
12900
1,68
2830
1,23
2650
14,0
12040
1,57
2700
1,15
2520
13,0
11180
1,47
2570
1,08
2400
12,0
10320
1,37
2440
1,00
2280
11,0
9460
1,26
2300
0,92
2150
10,0
8600
1,15
2170
0,85
2030
9,0
7740
1,05
2030
0,77
1900
8,0
6880
0,94
1890
0,69
1770
7,0
6020
0,83
1750
0,61
1640
6,0
5160
0,72
1600
0,53
1510
5,0
4300
0,60
1450
0,44
1370
4,0
3440
0,49
1290
0,36
1230
3,4
2924
0,42
1200
0,31
1150