35
A
++
A
+
A
B
C
D
E
F
G
24
kW
A
VICTRIX EXA 24 X 1 ErP
51
dB
INS
TALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
AN
3.23 PRODUCT FICHE (IN COMPLIANCE WITH REGULATION 811/2013).
3.22 TECHNICAL PARAMETERS FOR COMBINATION BOILERS (IN COMPLIANCE WITH REGULATION 813/2013).
Efficiencies in the following tables refer to the gross calorific value.
Model/s:
Victrix EXA 24 X 1 ErP
Condensing Boilers:
SI
Low temperature boiler:
NO
Boiler type B1:
NO
Co-generation appliance for central heating:
NO
Fitted with supplementary heating system:
NO
Mixed heating appliance:
NO
Element
Symbol
Value
Unit
Element
Symbol
Value
Unit
Nominal heat output
P
n
24
kW
Seasonal energy efficiency of central
heating
η
s
92
%
For central heating only and combination boilers: useful heat output
For central heating only and combination boilers: useful efficiency
At nominal heat output in high tempera-
ture mode (*)
P
4
23.7
kW
At nominal heat output in high tempera-
ture mode (*)
η
4
88.4
%
At 30% of nominal heat output in a low
temperature mode (**)
P
1
7.1
kW
At 30% of nominal heat output in a low
temperature mode (**)
η
1
97.0
%
Auxiliary electricity consumption
Other items
At full load
el
max
0.039
kW
Heat loss in standby
P
stby
0.078
kW
At partial load
el
min
0.019
kW
Ignition burner energy consumption
P
ign
0.000
kW
In standby mode
P
SB
0.006
kW
Emissions of nitrogen oxides
NO
X
40
mg /
kWh
For mixed central heating appliances
Stated load profile
Domestic hot water production efficiency
η
WH
%
Daily electrical power consumption
Q
elec
kWh
Daily gas consumption
Q
fuel
kWh
Contact information
IMMERGAS S.p.A. VIA CISA LIGURE, 95 - 42041 BRESCELLO (RE) ITALY
(*) High temperature mode means 60°C on return and 80°C on flow.
(**) Low temperature mode for condensation Boilers means 30°C , for low temperature boilers 37°C and for other appliances 50°C of return tempera-
ture.
Parameter
value
Annual energy consumption for the heating function (Q
HE
)
74.4 GJ
Annual electricity consumption for the domestic hot water function
(AEC)
---
Annual fuel consumption for the domestic hot water function (AFC)
---
Seasonal space heating energy efficiency (η
s
)
92 %
Water heating energy efficiency ( η
wh
)
---
For proper installation of the appliance refer to chapter 1 of this booklet (for the in-
staller) and current installation regulations. For proper maintenance refer to chapter
3 of this booklet (for the maintenance technician) and adhere to the frequencies and