23
5-2
5-3
5-4
Remove the rear cover of the heat pump
PLEASE NOTE:
always disconnect the device
from the power supply before starting any work.
Note:
This operation is only needed for complex
operations: (cleaning the evaporator, works on
the fan, works on the compressor, etc.).
PLEASE NOTE:
it is essential to disconnect the
power cable on the terminal board, so that the
rear cover of the heat pump can be removed
(Fig. 5-2).
Remove the five screws from the cover with a
screwdriver (Fig. 5-3).
Access to the auxiliary electric unit of the
boiler. 5-4).
To access the auxiliary power unit, proceed as
follows:
-Remove the lower tap of the column releasing it,
-Unscrew the 2 fastening screws on each side
of the column,
-Slide the column down a few centimeters to free
it from the console,
- Press the centre of the column to open it and
release it from the guide rails.