7
1-1
1
INTRODUCING THE
PRODUCT
1.1 IMPORTANT ADVICE.
Transport and storage.
The product may be
transported in upright position on a pallet, or
rotated by 90° on a side.
The appropriate side is shown clearly on an infor-
mation label placed on the product packing box.
It is forbidden to transport the product lying on
its other sides as it could irreparably damage it.
We recommend you strictly follow these in-
structions.
The product warranty is rendered null and void
if the above instructions are not complied with.
The manufacturer declines
any liability for any
faults to the product resulting from transport or
handling not complying with the above recom-
mendations.
Under no circumstances may this product be
stacked (Fig. 3-1).
1.2 TECHNICAL FEATURES.
Safety directives.
The installation work and
commissioning of thermodynamic water heaters
can be hazardous due to high pressure and live
electrical parts.
Thermodynamic water heaters must be installed,
commissioned and serviced by trained and
qualified staff only.
POSITIONS ALLOWED DURING
TRANSPORT
POSITIONS NOT ALLOWED DURING
TRANSPORT
Technical characteristics
Unit of
measurement
Rapax
200 V3
Rapax
200 SOL V3
Rapax
300 V3
Rapax
300 SOL V3
Dimensions
mm
H 1617 x L 620 x P 665
H 1957 x L 620 x P 665
Empty weight (version without coil)
kg
80
-
92
-
Empty weight (version with coil)
kg
-
97
-
111
Tank capacity
L
200
197
270
263
Hot + cold water fitting
-
3/4” M
Anti-corrosion protection
-
Magnesium anode
Maximum operating pressure
bar
8
Electrical connection (voltage/frequency)
V
230 V single-phase 50 Hz
Max total power absorbed by the device
W
2300
Max power absorbed by heat pump
W
700
Power absorbed by auxiliary electrical unit
W
1600
COP (at 15°C)
3.05
3.07
3.61
3.44
Setting range of the water temperature of the heat pump
°C
from 50 to 62 (temperature factory setting 52°C)
Temperature range for using the heat pump (air temperature)
°C
from -5 to +43
Coating diameter
mm
160
Acoustic output
db (A)
53
Air flow rate without ducts - Speed 1
m
3
/h
310
Air flow rate without ducts - Speed 2
m
3
/h
390
Load losses acceptable on ventilation circuit, without affecting
performance
Pa
25
Coolant
-
R513A
Mass of coolant fluid
kg/l
0.80
0.86
Coolant volume
Ton CO
2
Eq.
0.50
0.54