1.9 SYSTEM CONNECTION.
Attention:
to avoid burns caused by the excessive
temperatures of the DHW, a cold water mixing
valve must be installed or a device that limits
the output DHW to a maximum temperature
of 60°C +/- 5°C.
1.10 BY-PASS KIT (OPTIONAL).
This kit allows you to install a bypass on the
DHW circuit of a storage tank unit with natural
circulation to keep it from freezing during the
winter season (see the relative instruction sheet).
General indications.
- The pipes to implement the system are supplied
with the kit.
- With the system closed, you must partially
discharge the DHW circuit pressure of the
storage tank unit by means of the specific cock.
Domestic hot
water outlet
Domestic cold water
inlet
STD.005441/000