3.19 COMBUSTION PARAMETERS.
- The data relevant to domestic hot water per-
formance refer to a dynamic inlet pressure of
2 bar and an inlet temperature of 15°C; the
values are measured directly at the boiler outlet
considering that to obtain the data declared
mixing with cold water is necessary.
- * Efficiencies refer to the lower heating value
3.20 TECHNICAL DATA.
Nominal heat input
kW (kcal/h)
26.2 (22492)
DHW minimum heat input
kW (kcal/h)
8.3 (7116)
CH minimum heat input
kW (kcal/h)
10.9 (9357)
Nominal heat output (useful)
kW (kcal/h)
23.8 (20468)
DHW minimum heat output (useful)
kW (kcal/h)
7.0 (6020)
CH minimum heat output (useful)
kW (kcal/h)
9.4 (8084)
* Efficiency at nominal heat output
%
91.0
* Efficiency at 30% nominal heat output load
%
88,0
Heat loss at case with burner On/Off
%
2.30 / 1.20
Heat loss at flue with burner On/Off
%
6.70 / 0.09
Central heating circuit max. operating pressure
bar
3
Central heating circuit max. operating temperature
°C
90
Adjustable central heating temperature
°C
35 - 85
System expansion vessel total volume
l
4.0
Expansion vessel factory-set pressure
bar
1
Water content in generator
l
2.5
Total head available with 1000 l/h flow rate
kPa (m H
2
O)
27,3 (2,78)
Hot water production useful heat output
kW (kcal/h)
23.8 (20468)
Domestic hot water adjustable temperature
°C
30 - 60
Min. pressure (dynamic) domestic hot water circuit
bar
0.3
Domestic hot water circuit max. working pressure
bar
10
Minimum D.H.W. flow rate
l/min
1.5
Drawing capacity in continuous duty (∆T 30°C)
l/min
11,4
Weight of full boiler
kg
28.6
Weight of empty boiler
kg
26.1
Electrical connection
V/Hz
230/50
Power input
A
0.4
Installed electric power
W
45
Pump consumption
W
34
Value EEI
-
≤ 0,20 - Part. 3
Equipment electrical system protection
-
IPX4D
Boiler flue circuit resistance
Pa
1.3
NO
X
class
-
3
Weighted NO
X
mg/kWh
150
Weighted CO
mg/kWh
27
Type of appliance
B11
BS
Category
II 2H3+
G20
G30
G31
Gas nozzle diameter
mm
1,30
0,79
0,79
Supply pressure
mbar (mm H
2
O)
20 (204)
29 (296)
37 (377)
Flue flow rate at nominal heat output
kg/h
73
75
74
Flue flow rate at min heat output
kg/h
61
57
58
CO
2
at Q. Nom./Min.
%
5,00 / 1,80
5,65 / 2,25
5,70 / 2,20
CO with 0% O
2
at Q. Nom./Min.
ppm
95 / 60
125 / 75
115 / 69
NO
X
with 0% O
2
at Q. Nom./Min.
mg/kWh
245 / 125
362 / 152
338 / 176
Flue temperature at nominal output
°C
94
94
95
Flue temperature at minimum output
°C
77
81
84
Combustion parameters: measuring conditions
of useful efficiency (flow temperature/return
temperature= 80/60 °C), ambient temperature
reference = 15°C.