27
INS
TALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
AN
1st Level Button
2nd Level
Button
3rd Level
Button
4th Level
Button
Description
M3
D
C
P31
D
C
AUTO
(Default)
D
x
select
C
The display lights up when the burner
is ignited and when the controls are ac-
cessed, it remains on for 5 seconds after
the last operation performed
ON
The display is always lit up
OFF
The display only lights up when the
controls are accessed and remains on for 5
seconds after the last operation performed
P32
D
C
P32/B
D
C
ITALIANO
D
x
select
C
All descriptions are given in Italian
A1
(Default)
All descriptions are given in alphanumeri-
cal format
P33
D
C
OFF
(Default)
D
x
select
C
In winter mode, by activating this func-
tion it is possible to activate the room cen-
tral heating function even if the eventual
Remote Control or TA are out of service.
ON
RESET
D
x
select
C
By pressing button “D” the customisations
made are zeroed, restoring the settings
“P31”in “ILL. AUTO” and “P32/B” in
“ITALIANO” set in the factory
Customisations Menu “M3”.
This menu contains
all functioning options that can be customised.
(The first item of the various options that appears
inside the parameter is that selected by default).
Attention:
if the international language is to be
restored
(A1)
, proceed as follows:
- press button "D" to access the configuration
menu.
- turn selector switch "3" to
“PERSONAL”.
- press button "D" to confirm.
- turn selector switch "3" to
“DATI”
.
- press button "D" to confirm.
- turn selector switch "3" to
“LINGUA”
.
- press button "D" to confirm.
- turn selector switch "3" to
“A1”
.
- press button "D" to confirm.
At this point the international items indicated in
the menu tables appear on the display.
1st Level Button
2nd Level
Button
Description
M9
D
C
P91
D
C
Displays the current temperature of the low temperature zone number 2
P92
D
C
Displays the current temperature of the low temperature zone number 3
P93
D
C
Defines the flow temperature of the zone number 2 at low temperature.
With external probe (Optional) present the flow temperature can be corrected with respect to the
operation curve set by the external probe. See OFFSET on external probe graph (Fig. 1-6) modifying
temperature from -15°C to +15°C.
P94
D
x
select
C
Defines the flow temperature of the zone number 3 at low temperature.
With external probe (Optional) fitted the flow temperature may be corrected with respect to the
operation curve set by the external probe. See OFFSET on external probe graph (Fig. 1-6) changing
temperature from -15°C to +15°C.
Zone Menu (optional) “M9”.
The “M9” zone
menu is only activated if the board detects con-
nection to an additional zone board (optional).
This menu contains the temperature settings of
additional zones.