1.2  MAIN DIMENSIONS.

Key:

  G  -  Gas supply

  R  -  System return

  M  -  System delivery

  RC  -  Domestic hot water re-circ.

 AC  -  Domestic hot water outlet

  AF  -  Domestic cold water inlet 

  V  -  Electric attachment

1

  INSTALLATION OF THE 

BOILER

1.1 INSTALLATION 

RECOMMENDATIONS.

The Avio 24 2 ErP boiler has been designed for 

wall mounted installation only, for heating and 

production of domestic hot water for domestic 

use and similar purposes. 

The place of installation of the appliance and 

relative Immergas accessories must have suitable 

features (technical and structural) such to allow 

(always in safety, efficiency and comfortable 

conditions): 

-  installation (according to the provisions of the 

technical legislation and technical regulations); 

-  maintenance operations (including scheduled, 

periodic, routine and special maintenance); 

- removal (to outdoors in the place for loading 

and transporting the appliances and compo-

nents) as well as their possible replacement 

with equivalent appliances and/or components.

The wall surface must be smooth, without any 

protrusions or recesses enabling access to the 

rear part. They are NOT designed to be installed 

on plinths or floors (Fig. 1-1). 

Only professionally enabled companies are 

authorised to install Immergas gas appliances. 

Installation must be carried out according to 

regulation standards, current legislation and in 

compliance with local technical regulations and 

the required technical procedures. 

Attention

: Immergas declines all liability for 

damages caused by boilers removed from other 

systems or for any non-conformities of such 

equipment.
Before installing the appliance, ensure that it is 

delivered in perfect condition; if in doubt, contact 

the supplier immediately. 

Packing materials (staples, nails, plastic bags, 

polystyrene foam, etc.) constitute a hazard and 

must be kept out of the reach of children. If the 

appliance is installed inside or between cabinets, 

ensure sufficient space for normal servicing; 

therefore it is advisable to leave a clearance of 

at least 3 cm between the boiler casing and the 

vertical sides of the cabinet.

Leave adequate space above the boiler for 

possible water and fume removal connections.

At least 60 cm must be left below the boiler 

in order to guarantee replacement of the 

magnesium anode.

It is just as important that the intake grids are 

not obstructed.

Keep all flammable objects away from the 

appliance(paper, rags, plastic, polystyrene, etc.).

Do not place household appliances underneath 

the boiler as they could be damaged if the 

safety valve intervenes (if not conveyed away 

by a draining funnel), or if there are leaks from 

the hydraulic connections; on the contrary, the 

manufacturer cannot be held responsible for 

any damage caused to the household appliances.

For the aforementioned reasons, we recommend 

not placing furnishings, furniture, etc. under 

the boiler. 

In the event of a malfunction, fault or incorrect 

operation, turn the appliance off and contact 

an authorised company (e.g. the Authorised 

Technical Assistance centre, which has 

specifically trained staff and original spare parts). 

 Do not attempt to modify or repair the ap-

pliance alone. Failure to comply with the above 

implies personal responsibility and invalidates 

the warranty.
• Installation regulations:
  - installation of these boilers in bedrooms, 

studio flats and bathrooms, or in premises 

where there are wood fired heaters (or by 

solid fuels in general) and in premises next 

to or connected to them, is subject to the 

regulatory/legislative provisions in force in 

the country. 

  - installation in places with a fire risk is 

prohibited (for example: underground car 

parks, garages), potentially dangerous places, 

gas appliances and relative flue ducts.

  - installation is prohibited on the vertical 

projection of cooking hobs;

  - installation is forbidden in places/rooms 

that constitute public areas of apartment 

buildings, internal stairways or other 

escape routes (e.g. landings, entrance halls, 

etc.) unless otherwise provided by local 

regulations;

  -  installation is also forbidden in places/rooms 

that constitute public areas of apartment 

buildings such as cellars, entrance halls, attics, 

lofts, etc., unless otherwise provided for by 

local regulations in force;

  - Type B open chamber boilers must not be 

installed in places where commercial, artisan 

or industrial activities take place, which use 

products that may develop volatile vapours 

or substances (e.g. acid vapours, glues, paints, 

solvents, combustibles, etc.), as well as dusts 

(e.g. dust deriving from the working of wood, 

coal fines, cement, etc.), which may be dama-

ging for the components of the appliance and 

jeopardise functioning.

  - They must also be installed in an environ-

ment in which the temperature cannot fall 

below 0°C. They must not be exposed to 

atmospheric agents. 

  -  This natural draught boiler can be connected 

only to a multiple branched flue served by 

a variety of users in existing buildings. The 

boiler takes the combustion air directly from 

the installation room and is equipped with 

draught-breaker/anti-wind device. Due to 

lower efficiency, any other use of this boiler 

must be avoided as it would lead to greater 

consumption and higher operating costs.

Important: 

wall mounting of the boiler must 

guarantee stable and efficient support for the 

generator.

The plugs (standard supply) are to be used only in 

conjunction with the mounting brackets or fixing 

template to fix the appliance to the wall

; they only 

ensure adequate support if inserted correctly 

(according to technical standards) in walls made 

of solid or semi-hollow brick or block. In the 

Summary of Contents for AVIO 24 2 ERP

Page 1: ...tenance Technician IE 1 038455ENG Wall hung boiler with storage tank open chamber type B and natural draught The European regulation 813 2013 provides that this boiler can be installed only to replace...

Page 2: ...the regulations in force and principles of good practice In compliance with legislation in force the systems must be designed by qualified professionals within the dimensional limits established by t...

Page 3: ...s 13 2 7 Boiler shutdown 14 2 8 Restoring heating system pressure 14 2 9 Draining the system 14 2 10 Draining the boiler 14 2 11 Anti freeze protection 14 2 12 Case cleaning 14 2 13 Decomissioning 14...

Page 4: ...leaks from the hydraulic connections on the contrary the manufacturer cannot be held responsible for any damage caused to the household appliances For the aforementioned reasons we recommend not placi...

Page 5: ...nger it is recommended to install the polyphosphate proportioner kit in the presence of water whose characteristics can give rise to scale deposits 1 7 ELECTRICAL CONNECTION The Avio 24 2 ErP boiler h...

Page 6: ...nnot be used for plants divided into zones Electrical connection of the Remote Friend ControlV2 chronothermostat On Off Op tional or Mini The operations described below must be performed after having...

Page 7: ...eck if the cap is loose Open the radiator air vent valves Close vent valves only when water is delivered Close the filling valve when the boiler pressure gauge indicates approx 1 2 bar N B During thes...

Page 8: ...fficient to press button 1 once To change operation mode press the button for between 2 to 10 seconds until the current configuration flashing each time the button is pressed all possible functions ar...

Page 9: ...tal head available to the system with pump at speed 4 A2 Power absorbed by the pump at speed 2 A3 Power absorbed by the pump at speed 3 A4 Power absorbed by the pump at speed 4 Circulator pump absorbe...

Page 10: ...motorised 7 System filler tap 8 System expansion tank 9 Domestic water probe 10 Stainless steel boiler 11 3 bar safety valve 1 19 BOILER COMPONENTS 12 System emptying tap 13 8 bar safety valve 14 Boi...

Page 11: ...d dangerous to obstruct the air intake even partially for the ventilation of the room in which the boiler is installed Due to the danger operation is also prohibited in the same room as suction device...

Page 12: ...anti freeze function is activated 2 6 FAULT AND ANOMALY SIGNALS The Avio 24 2 ERP boiler signals ant anomaly by flashing of one of the LEDs from 4 to 8 or LEDs 1 and 2 coupled to LED 7 On any remote...

Page 13: ...tioned on Summer or Winter To avoid keeping the system switched on in case of a prolonged absence the system must be drained completely or antifreeze substances added to the heating system water In bo...

Page 14: ...e appliance combustion products check that there is no backflow of combustion products into the room even during functioning of fans 3 1 HYDRAULIC LAYOUT Key 1 Gas valve 2 Stainless steel coil for boi...

Page 15: ...out by an authorised company e g Authorised After Sales Technical Assistance Service Smell of gas Caused by leakage from gas circuit pipelines Check sealing efficiency of gas intake circuit Irregular...

Page 16: ...ases and in an anti clockwise direction it decreases Adjust the boiler minimum thermal input Fig 3 3 N B only proceed after having calibrated the nominal pressure Adjustment of the minimum thermal inp...

Page 17: ...ng Led 8 Heating switch on delay request from Room thermostat and Remote Friend ControlV2 The boiler is set to switch on immediately after a request In the case of particular plants e g area plants wi...

Page 18: ...ntion of electrical main electrical switch on boiler system control thermostat intervention domestic water control thermostat intervention Check that the internal system is properly sealed according t...

Page 19: ...at 0 of O2 at Q Nom Min ppm 177 81 279 115 240 108 Flue temperature at nominal heat output C 101 106 104 Flue temperature at minimum heat output C 74 77 76 METHANE G20 BUTANE G30 PROPANE G31 HEAT POW...

Page 20: ...2 40 0 57 Heat loss at flue with burner On Off 7 20 0 43 Heating circuit max working pressure bar 3 Heating circuit max working temperature C 90 Adjustable heating temperature C 35 85 Total volume sys...

Page 21: ...e technical data are shown on the boiler data plate ENG Model Model code Serial Number Check PIN code Type of installation ref CEN TR 1749 Minimum heating capacity domestic Minimum heating capacity he...

Page 22: ...partial load elmin 0 014 kW Ignition burner energy consumption Pign 0 000 kW In standby mode PSB 0 003 kW Emissions of nitrogen oxides NOX 132 mg kWh For mixed central heating appliances Stated load p...

Page 23: ...ntary heat pump From fiche of heat pump Solar contribution and Supplementary heat pump Select smaller value Boiler and supplementary heat pump installed with low temperature heat emitters at 35 C From...

Page 24: ...energy efficiency of the package of products provided far in this fiche may not correspond to its actual energy efficiency once installed in a building as the efficiency is influenced by further facto...

Page 25: ...contribution From fiche of solar device 1 I 2 1 1 x I 10 x II III I Auxiliary electricity 3 G F E D C B A A A A 27 27 27 28 27 27 27 28 30 30 30 32 33 34 35 36 36 37 38 40 39 50 55 60 65 75 80 85 100...

Page 26: ...under colder and warmer climate conditions Colder 0 2 x Warmer 0 4 x Declared load profile Solar contribution From fiche of solar device 1 ___ 2 1 1 x ___ 10 x ____ ____ ____ Auxiliary electricity 3...

Page 27: ......

Page 28: ...mergas S p A 42041 Brescello RE Italy Tel 0522 689011 Fax 0522 680617 Certified company ISO 9001 This instruction booklet is made of ecological paper Cod 1 038455ENG rev ST 002233 003 04 18 Irlandese...

Reviews: