4.2 COMBUSTION PARAMETERS
Gas type
G20
G31
Supply pressure
mbar (mm H
2
O)
20 (204)
31 (377)
Gas nozzle diameter
mm
5
5
Flue flow rate at D.H.W. nominal heat output
kg/h (g/s)
42 (11.54)
43 (11.83)
Flue flow rate at heating nominal heat output
kg/h (g/s)
34 (9.44)
34 (9.56)
Flue flow rate at min heat output
kg/h (g/s)
7 (1.98)
7 (2.02)
CO
2 to nominal Q.
%
9.2 (± 0,2)
10.2 (± 0,2)
CO
2 to ignition Q.
%
9 (± 0,2)
10 (± 0,2)
CO
2 to minimum Q.
%
9 (± 0,2)
10 (± 0,2)
CO with 0% O
2
at Nom./Min. Q.
ppm
230 / 9
240 / 69
NO
x
with 0% O
2
at Nom./Min. Q.
mg/kWh
37 / 26
43 / 39
Flue temperature at nominal output
°C
65
65
Flue temperature at minimum output
°C
56
57
Max air combustion temperature
°C
50
50
Combustion parameters: measuring conditions of useful efficiency (flow temperature/return temperature= 80 / 60 °C), ambient temper-
ature reference = 15°C.
Available head
intake / exhaust with
F0 = 0
Available head
intake / exhaust with
F0 = 1
Available head
intake / exhaust with
F0 = 2
Pa
Pa
Pa
68
113
152