1.5  DOMESTIC HOT WATER STORAGE 

TANK UNIT.

The storage tank unit must be connected to a 

boiler and a solar panel system. It contains large 

coiled heat exchanger pipes, which help notably 

reduce hot water production times. 

- Boiler protection: 
  - Vitrified steel Storage Tank Units: treatment 

with glazed enamel (also called vitrification), 

gives the product a high capacity of inalter-

ability of the chemical-physical features of 

the domestic hot water. 

  Additional quality support is provided by 

magnesium anodes installed, by standard, on 

the product. On request it is possible to install 

impressed current anodes.

- Efficiency: the coiled heat exchange surface is 

sized to supply large quantities of hot water.

-  Heat insulation: the storage tanks with a capac-

ity of 1000, 1500 and 2000 litres are insulated 

with flexible polyurethane with a thickness of 

100 mm., CFC and HCFC-free. 

-  External casing: this is made of a coupled PVC 

sheath.

N.B.:

 every year a skilled technician (e.g. Au-

thorised After-sales Service), must check the 

efficiency of the storage tank unit's Magnesium 

Anode. The storage tank unit is prepared for 

introduction of the domestic hot water pump 

fitting.

1.6  KITS AVAILABLE ON REQUEST.

•  Recirculation kit (on request). The storage tank 

unit is prepared for application of the pump 

kit. Immergas supplies a series of fittings and 

attachments that allow connection between 

the storage tank unit and domestic hot water 

system. The pump kit attachment is also envi-

sioned on the template.

• Solar panels kit (on demand). If solar panels 

are to be used for the production of domestic 

hot water, Immergas supplies the solar panels 

kit on demand.

The above-mentioned kits are supplied complete 

with instructions for assembly and use.

1.7  MAIN COMPONENTS.

Key:

  1  -  Inspection flange

  2  -  Magnesium anode

  3  -  Insulating material

  4  -  Storage tank coil

  5  -  DHW probe (NTC 10 k hom at 25°C  

supplied as per standard)

  6  -  Solar panels coil

  7  -  Solar panel probe

  8  -  Storage tank unit draining valve

  9  -  Magnesium anode (UB 1500 - UB 2000 V2)

UB 1000 - 1500 - 2000 V2 Vitrified Storage Tank

Summary of Contents for 3.025605

Page 1: ...STORAGE TANK UNIT 1000 1500 2000 V2 IE Instruction and recommendation booklet 1 041262ENG...

Page 2: ......

Page 3: ...is necessary to comply with the provisions specified in the regulations in force and principles of good practice In compliance with legislation in force the systems must be designed by qualified profe...

Page 4: ...stic hot water storage tank unit 7 1 6 Kits available on request 7 1 7 Main components 7 2 Use and maintenance instructions 8 2 1 Cleaning and maintenance 8 2 2 Operation 8 2 3 Emptying the storage ta...

Page 5: ...sides of the cabinet In the event of malfunctions faults or incorrect operation turn the storage tank off and contact an authorised company e g the Authorised Technical Assistance centre which has sp...

Page 6: ...k integration resistance AF Domestic cold water inlet RP Return from solar panels MP Flow to solar panels RU Return from storage tank RC Recirculation Optional MU Flow to storage tank AC Domestic hot...

Page 7: ...of a coupled PVC sheath N B every year a skilled technician e g Au thorised After sales Service must check the efficiency of the storage tank unit s Magnesium Anode The storage tank unit is prepared f...

Page 8: ...cale formation The DHW in the storage tank is heated with the passage of CH solar water which circulates inside the coils inside the storage tank unit itself In all cases the maximum temperature insid...

Page 9: ...control unit 3 Solar circulation unit 4 Solar system expansion vessel 5 6 bar safety valve 6 System probe and venting unit 7 Mixing valve 8 V2 Storage tank unit 9 Storage tank unit thermometer 10 Insp...

Page 10: ...with a jet of water During cleaning be very careful not to damage the protection inside the tank 3 3 STORAGE TANK UNIT TECHNICAL DATA When you have completed the process put the flange back in place u...

Page 11: ...11...

Page 12: ...mmergas com Immergas S p A 42041 Brescello RE Italy Tel 0522 689011 Fax 0522 680617 Certified company ISO 9001 This instruction booklet is made of ecological paper Cod 1 041262ENG rev ST 003317 000 09...

Reviews: