background image

5

Feed and RPM Stages

IML-RESI PD-Series

Hard wood:  
 

Stage 2 (50 cm/min) 

 

to Stage 4 (175 cm/min)

Soft wood:  
 

Stage 3 (100 cm/min) 

 

to Stage 5 (250 cm/min)

Utility poles:  
 

Stage 1 (100 cm/min) 

 

to Stage 3 (200 cm/min)

General Feed Stages:

Hard wood:  
 

2500 RPM

Soft wood:  
 

2500 RPM

Utility poles:  
 

3000 RPM

General RPM Stages:

Press the black key briefly to change the feed speed. In order to change 
the feed speed the main menu has to be displayed.  

Please note: 

These values are only guide values. They vary depending on 

different wood qualities and on the status of the drilling needle.

Conduct a Measurement

IML-RESI PD-Series

Make sure the main menu is displayed. Press the instrument against the 
object that has to be examined. Make sure the 45° adapter sleeve is 
pressed correctly. This safety function prevents accidantal measurements- 
The security system will detect the compression and displays it in the 
status bar of the main menu. You are not able to start a measurement 
when the adapter is not pressed correctly. 
After pressing briefly the red key the drilling will start and the graphic 
shown above will appear.

Summary of Contents for PowerDrill IML-RESI PD-Series

Page 1: ...IML PowerDrill Brief Instruction Uncompromisingly precision for all applications...

Page 2: ...2 System Components IML RESI PD Series 1 Handle 2 Control Unit 3 Battery 4 45 Adapter 5 Additional Handle 6 Navigation Knob 7 Display 8 Bluetooth Antenna 9 USB Interface 1 2 3 4 6 7 8 9 5...

Page 3: ...Make sure the instrument is swit ched off before removing the bat tery Press the release button of the battery and remove it backwards from the mounting IML RESI PD Series Switching the device On and...

Page 4: ...choose for example a tree number The ID is sto red with each measurement Changes the remark You can choose an individual comment The remark is sto red with each measurement Shows the last measurement...

Page 5: ...s are only guide values They vary depending on different wood qualities and on the status of the drilling needle Conduct a Measurement IML RESI PD Series Make sure the main menu is displayed Press the...

Page 6: ...le arrow allows the movement of the feed unit The drilling needle is extended until it reaches the changing position Then the message displayed above appears Hold the blade of the drilling needle with...

Page 7: ...trument can be displayed by selecting the device information symbol in the main menu The serial number of the instrument as well as the serial numbers of the electronic unit are shown in this menu Fur...