9.
How to start-up with SM-USB-Module?
Install USB-Driver (from USB-Stick)
Connect the SM-USB to the PC and the installation will be accomplished
automatically
Install TrimeTool software (from USB-Stick)
Check the setting of the COM-Port in the device manager and setup the specific
COM-Port in the TrimeTool software (COM1-COM9 possible)
Connect your sensor to the SM-USB either via RS485 or via IMP-Bus
Run TrimeTool software and Scan bus
The sensor has to be shown in the module list
10.
Technical Data:
Power supply:
5V/DC (from USB)
Power consumption
(IDLE):
Approx. 50mA @ 5D/DC
Current max.
(protected):
500mA
External power (to
sensor):
7..24V/DC
Interfaces:
USB 1.1 (2.0 compatible)
RS485 (to sensor)
IMP-Bus (to sensor)
Accessories:
USB-Cable (1,8m)
Power supply cable with banana plugs (1,8m)
2x screw terminal plug
USB-Stick with driver and software
Optional available
accessories:
Wall power plug 12VDC/2A
Adapter screw terminal
7-pin male connector (RS485)
Adapter screw terminal
4-pin male connector (IMP-Bus)
Dimensions (WxDxH)
98x64x37mm
Further specifications: Power supply out of USB only for single sensor!
For multiple sensors use external power supply!