Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document. © 2017 Norgren Automation Solutions, LLC
2.
Clean M6 X 30 mm SHCS for sensor. Apply liquid Loctite 262 or equivalent to pivot hole in frame. Insert screw
through sensor and into frame. Tighten the M6 SCHS
120in-lb
.
H. Calibrating In-Direct Sensor
Sensor must be calibrated whenever any part of the gripper is replaced including pads.
1) Part Present
a)
To program the sensor for a particular material thickness, apply air to the gripper and grip on the material
thickness which is to be used for the particular job. With an object such as a small Allen wrench, press the
button until the Red LED corresponding to the material range of the job lights as shown on the label.
b)
Verify calibration:
(1)
Close the gripper with no material between the pads. The LED should be off.
(2)
Close the gripper on a single blank of material. The Red LED corresponding to your material range should
be on.
2) Double Blank
a)
To program the sensor for a particular material thickness, apply air to the gripper and grip on the material
thickness which is to be used for the particular job. With an object such as a small Allen wrench, press the
button until the Red LED(s) corresponding to the material range of the job lights as shown on the label.
b)
Verify calibration:
(1)
Close the gripper with no material between the pads. The LED(s) should be off.
(2)
Close the gripper on a single blank of material. The Red LED(s) corresponding to you material range
should be on.
Note:
double blank sensor not available on flange jaw gripper
08
2/17
12680UI REV: 003
User Instructions for PGS20 and PGS42 Grippers