IMG BRASIL BIMG METVISA FTE.150 Instruction Manual Download Page 1

 

 

Summary of Contents for BIMG METVISA FTE.150

Page 1: ...1 ...

Page 2: ...ials ensure superior products consumed in Brazil and in more than 25 countries worldwide THE RELIABILITY AND CERTAINTY OF A GOOD PRODUCT ARE IN THE NAME IMPORTANT PRODUCT FOR PROFESSIONAL USE DO NOT USE BEFORE READING THE MANUAL CAREFULLY IN CASE OF QUESTIONS PLEASE CONTACT US IMG BRASIL Indústria de Máquinas para Gastronomia Ltda CNPJ 11 193 347 0001 14 CREA 131726 3 Rod Antônio Heil KM 23 Nº 582...

Page 3: ...olonged Interruption in Use of Equipment 26 6 Analysis and Troubleshooting 26 6 1 Problems possible causes and solutions 26 7 Appliance Life and Components 27 8 ANNEXES 26 Electrical Schematic FTE 150 Voltage 220 V Single Phase Connection 26 Electrical Schematic FTE 150 Voltage 220 V Three Phase Connection 26 Electrical Schematic FTE 300 Voltage 220 V Three Phase Connection 27 Electrical Schematic...

Page 4: ...ion of the same one The operator must use the Adequate PPE equipment for individual safety For example suitable gloves protecting the hands from burns by heating the oven The operator must always be aware of situations that can cause a risk of accidents and avoid them Do not operate the equipment in damp locations or with wet clothing and shoes Wear proper footwear this will prevent electric shock...

Page 5: ... with safety system that automatically turns off the fan and the heating of the oven when it is open Because it is tempered glass and has lighting the door allows you to visualize the foods being baked without having to open it 3 Stand with the appropriate height for the use of the equipment following requirements for good ergonomics To view the parts described above refer to the image in item 2 1...

Page 6: ...it is able to carry out the works to which they are proposed ATTENTION Whenever any item regarding the safety of the equipment such as cleaning or maintenance is removed reset it and confirm that it is performing its function correctly 2 Technical Features 2 1 Main Components For the equipment described in this manual safety in use cleaning maintenance and maximum hygiene are guaranteed by the des...

Page 7: ...0x2000 162 0 150 05 580x700 FTE150T220T60 6 mm 220 TF 24 9 FTE150T380T60 4 mm 380 TF 14 9 FTE150T220M50 10 mm 220 MF 41 9 FTE150T220T50 6 mm 220 TF 24 9 FTE150T380T50 4 mm 380 TF 14 9 FTE300220T60 10 mm 220 TF 48 18 1840x1800x2100 245 0 300 10 580x700 FTE300380T60 6 mm 380 TF 28 18 FTE300220T50 10 mm 220 TF 48 18 FTE300380T50 6 mm 380 TF 28 18 FTE300T220T60 10 mm 220 TF 48 18 1840x1800x2100 244 5 ...

Page 8: ... installed in countries with different standards dispose of the packaging in accordance with current regulations Dispose of the product correctly to help protect the environment For more information on recycling contact your local authorities waste disposal service or the shop where you purchased the product 3 Instalação 3 1 Equipment Layout In the installation it is essential to make this manual ...

Page 9: ...9 Follow the guidelines below to assemble the stand ...

Page 10: ...ts are tight To ensure correct operation and safety the equipment should be positioned in a sufficiently wide area with a well leveled dry and stable floor away from sources of heat and humidity and where there is no heavy traffic Install your equipment leaving a free area at the front and a distance of at least 50 cm around it The area should have sufficient space for inspection maintenance clean...

Page 11: ...sed of must comply with the rules of risk prevention and safety at work Regulatory standard NR 12 for Brazil or according to the regulation in force in your country Do not install near flammable materials or products The manufacturer shall not be liable for any direct or indirect damages caused by non compliance with these standards and other instructions presented in this manual 3 2 Hydraulic Ins...

Page 12: ... at most 78 kPa 8 mA ATTENTION It is recommended that the water be connected directly from the water box so as not to generate a high pressure or that it has variation as in the public network Very high water boxes should also be avoided It is also recommended to install a filter to eliminate water impurities avoiding the calcification and internal corrosion of the equipment Install a water log on...

Page 13: ...on with four wires Ground and Phases RST and voltage 380 V three phase connection has 5 wires Ground Neutral and RST Phases For cables that have Neutral their color is blue and is labeled with a sticker It is mandatory to connect the neutral wire to the neutral of the mains If the power cord is damaged it must be replaced with a new one The exchange must be made by the manufacturer authorized agen...

Page 14: ...F 50 FTE300 380 V TF 32 The ovens described in this manual are single voltage ie 127 V 110 V or 220 V If you need to change the voltage in your equipment contact the manufacturer or your authorized dealer ATTENTION Before turning on your equipment always check that the mains supply voltage is the same as the equipment voltage If it is not the same contact the manufacturer or authorized dealer The ...

Page 15: ...anual Your equipment has mechanical protections see item 1 2 Mechanical Safety and a safety system that prevents the turbine from running and heating if the door is open Removing or tampering with these safety components can cause serious risks to the operator ATTENTION Before using your equipment check the direction of rotation of the turbine For this position yourself in front of the oven the tu...

Page 16: ...ee description of each command below Power Button used to turn the equipment on and off In position 1 turns on in position 0 turns off Power Button Light used to turn the light located on the oven door on and off In position 1 turns on in position 0 turns off Controller Used to program temperature cooking time and steam The following is the description for each function ...

Page 17: ...ogrammed value and selects the cyclic steam function which emits steam automatically for 6 seconds and every 2 minutes factory default program To reprogram the cyclic steam follow the instructions below 11 Programming access key 12 Heating indicator LED on Reprogramming of single steam and cyclic steam To reprogram the steam time press the keys at the same time in that moment it will appear in the...

Page 18: ...rom the mains Follow the cleaning instructions in item 5 of this manual below ATTENTION For the first use of model equipment FTE 150 and FTE 300 models with carbon steel chamber with high temperature paint finish it is necessary to cure the paint inside the oven chamber To do this the empty oven must be switched on and the temperature raised to 220 C for a minimum of 60 minutes Follow the operatin...

Page 19: ...s the key 8 After the oven reaches the desired temperature open the oven door At this point it will automatically switch off the fan and the oven heating due to a safety system Only with the door open is possible switched off the turbine with the oven switched on 9 Place the perforated racks dimensions 580 x 700 mm inside the oven As soon as you close the door the fan and the heating will switch o...

Page 20: ...uctions presented in this manual 5 Cleaning and Maintenance 5 1 Cleaning Procedures and Products Used Your equipment is built with first line materials so use it correctly and you will get great satisfaction Keep your equipment always clean and well taken care of as this will make it have a much longer shelf life A daily cleaning of the equipment should be carried out in order to obtain a good fun...

Page 21: ... of Breakdowns The operator must be instructed to perform routine inspections making minor adjustments cleaning and observing signs of breaches that may occur Examples include checking for extraneous noise non execution by the equipment to the service to which it is proposed among others Actions such as these are essential to ensure a longer equipment life CAUTION When servicing even minor adjustm...

Page 22: ...ent will not turn on Lack of electricity Check for power on the network Check that the power cord is plugged into a wall outlet Voltage different from mains voltage Send the equipment to the nearest authorized service station or contact the factory Miscellaneous electrical problems motor capacitor contactor wiring fuse electric switch power cable buttons and burned resistor Open door The door has ...

Page 23: ... service station or contact the factory Uniform baking Temperature too high or too low Make adjustments to the controller according to the instruction manual Fan out of position Send the equipment to the nearest authorized service station or contact the factory Overloading Charge the oven respecting the spaces available on the racks Oven giving shock Lack of grounding Follow the instructions in it...

Page 24: ...26 8 ANNEXES Electrical Schematic FTE 150 Voltage 220 V Single Phase Connection NOTE FTE 150 oven uses nly one Door Light ...

Page 25: ...26 Electrical Schematic FTE 150 Voltage 220 V Three Phase Connection NOTE FTE 150 oven uses only one Door Light ...

Page 26: ...27 Electrical Schematic FTE 300 Voltage 220 V Three Phase Connection ...

Page 27: ...28 Electrical Schematic FTE 150 Voltage 380 V Three Phase Connection NOTE FTE 150 oven uses only one Door Light ...

Page 28: ...29 Electrical Schematic FTE 300 Voltage 380 V Three Phase Connection ...

Page 29: ...30 Explosion Design ...

Page 30: ...31 Explosion Design ...

Page 31: ...32 Explosion Design ...

Page 32: ...33 Explosion Design ...

Page 33: ...Oven Structure FTE 150T 01 FTE 150T GAB161 Right Side Oven Structure FTE 300 01 FTE 300 GAB134 Right Side Oven Structure FTE 300T 01 FTE 300T 10 POS147 Hexagonal Nut 02 FTE 150 FTE 300 POS155 Stainless Steel Hexagonal Nut 02 FTE 150T FTE 300T 11 PRA014 Hexagon Tapping Screw Stainless Steel Drilling Screw 21 FTE 150 T 37 FTE 300 T 12 POS005 Hexagonal Nut 08 FTE 150 FTE 300 POS021 Stainless Steel He...

Page 34: ...ower Cable 4 x 10 mm 01 FTE 300 T 220 TF CBE305 Power Cable 5 x 2 5 mm 01 FTE 150 T 380 TF CBE244 Power Cable 5 x 6 mm 01 FTE 300 T 380 TF 13 11 TCE030 Prensa Cabo PG16 01 FTE 150 T 220 MF TCE019 Press Cable PG11 01 FTE 150 T 220 TF 01 FTE 150 T 380 TF TCE028 Press Cable PG19 01 FTE 300 T 220 TF TCE041 Press Cable PG13 5 01 FTE 300 T 380 TF 13 12 FUS002 Medium Slide Fuse 01 13 13 DSJ018 Mini Disju...

Page 35: ... Electric Motor 1 4 HP 4P 50 HZ 220 V FTE 150 T 01 FTE 150 T MTE265 Electric Motor 3 4 HP 4P 60 HZ 220 V FTE 300 T 01 FTE 300 T MTE273 Electric Motor 3 4 HP 4P 50 HZ 220 V FTE 300 T 01 FTE 300 T 24 SBT390 Motor Support FTE 150 01 FTE 150 SBT401 Motor Support FTE 150T 01 FTE 150T SBT389 Motor Support FTE 300 01 FTE 300 SBT396 Motor Support FTE 300T 01 FTE 300T 25 TER004 Ceramic Fiber Blanket 01 26 ...

Page 36: ...CH074 Silicone Glass Support 08 FTE 150 T 10 FTE 300 T 34 8 VID003 Tempered Glass METVISA FTE 150 01 FTE 150 T VID001 Tempered Glass METVISA FTE 300 01 FTE 300 T 34 9 PRN004 Allen Screw 01 34 10 EIX184 Handle Axis 01 34 11 PRN001 Allen Screw S C 01 34 12 PIT014 Pin Type R 01 34 13 EIX174 Oven Handle Axis 01 34 14 BGT046 Threaded Bushing Handle 01 34 15 POS145 1 Hex Nut for Handle 01 34 16 BGT047 H...

Page 37: ...ate FTE 150 T 02 FTE 150 T 45 CVT027 High Stand FTE 150 T 01 FTE 150 T 46 PRS031 Stainless Steel Hexagonal Screw 02 47 CRC798 Lower Heat Containment Plate FTE 300 01 FTE 300 CRC1071 Lower Heat Containment Plate FTE 300T 01 FTE 300T 48 CUP016 Lateral Structure Protection Plate FTE 300 01 FTE 300 CUP023 Lateral Structure Protection Plate FTE 300T 01 FTE 300T 49 TER001 Rigid Panel Rock Wool FTE 300 T...

Page 38: ...39 Notes ...

Page 39: ......

Page 40: ...ustry Ltda CNPJ 11 193 347 0001 14 CREA 131726 3 Road Antônio Heil KM 23 Nº 5825 Neighborhood Limoeiro ZIP CODE 88352 502 Brusque SC Brazil Phone fax 55 47 3251 5555 Web Site www metvisa com br Mail sac metvisa com br export metvisa com br ...

Reviews: