3
Replace flush valve
1
Open cistern panel system
Push the bottom of cistern panel upwards,
turn the top of cistern panel about 30
0
,take
the panel out of the panel frame.
Remove the screw,take
the panel frame out
Close the stop valve,remove
the flexible connection pipe
Take the fill valve out at an angle.
Technical data:
.1
2 inch
standard inlet.
.The water pressures range is 0.2
a
4.0 bar
.The water temperature range is 2
0
a
45
0
.
.3L
L dual flush water volume,the flush water time is 3s
a
5s.
.The painted steel frame is corrosion resistant and can bear 400kgs of weight.
.The product can be installed in a wall of
0mm thick.
Maintenance Manual for the Concealed Cistern
(For InstallationWith Wall Hung Toilet)
Remove the screws and
take off the panel board
To remove the panel board ,turn it
over about 30 from the top,
take it out at an angle, carefully upwards
Pull out the fill valve from the coupling.
Pull up the fill valve a little.
Pull the flush valve with left hand
lightly,and with the right hand hold the
flush frame top and pull it out of
the coupling.
Move the flush frame to the
right and take it out at an angle
Pull the flush valve
upwards carefully
Turn the flush valve
upside down
Take the flush valve out at an angle
2
Replace fill valve
CF01
Wall hung WC bowl frame system with
chrome dual flush plate